3실형 인버터 열펌프 시스템의 냉방성능 측정 (Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System)

  • 정광진;최영돈;장효환;송재복;박윤철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가 (Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment)

  • 이철희;나환선;정훈;김강식
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

멀티형 인버터 열펌프의 냉방성능해석에 관한 연구 (Performance Analysis of a Multi-type Inverter Heat Pump)

  • 김영철;박근우;윤영;민만기;최영돈
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.153-159
    • /
    • 2001
  • A system simulation program was developed for a multi-type inverter heat pump. Electronic expansion valve(EEV) was used to extend the capacity modulating range of the heat pump as expansion device. The program was also developed to calculate actual system performance with the building load variation with climate during a year. The performance variation of a multi-type hat pump with two EEV and an inverter compressor was simulated with compressor speed, capacity, and flow area of the EEV. As a result, the optimum operating frequency of the compressor and openings of the expansion device were decided at a given load. As compressor speed increased, he capacity of heat pump increased, the capacity of heat pump increased. Therefore flow area of EEV should be adjusted to have wide openness. Thus the coefficient of performance(COP) of the heat pump decreased due to increasement of compressor power input. The maximum COP point at a given load was decided according to the compressor speed. And under the given specific compressor speed and the load, the optimum openings point of EEV was also decided. Although the total load of indoor units was constant, the operating frequency increased as the fraction of load in a room increased. Finally ad the compressor power input increased, the coefficient of performance decreased.

  • PDF

동시냉난방 열펌프 시스템의 운전모드별 성능특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics of a Simultaneous Heating and Cooling Heat Pump System at Each Operating Mode)

  • 강훈;이선일;주영주;정현준;김용찬;최종민
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.679-686
    • /
    • 2007
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, a 4-room simultaneous heating and cooling heat pump system was designed and its performance was measured at each operating mode. The system used R-410A and adopted variable speed compressor. The problems on the designed system were analyzed and defined. In addition, the solutions of the problems were suggested to improve system efficiency and to obtain the stable operation.

A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner Coupled with Ventilation System

  • Kwon, Yong-Il;Han, Hwa-Taik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.101-107
    • /
    • 2007
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in two different ways in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

Gas Heat Pump 구동을 위한 가스 엔진 제어기의 개발 (A Study on the development of Gas Engine Controller for Gas Heat Pump)

  • 이중현;고국원;고경철;김종형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.618-621
    • /
    • 2004
  • Compressors in Large Multi-room air conditioning system are often driven by gas heat pumps. The advantages of GHP are their high level of heating performance and low cost because they use the LNG fuel to drive engine. We developed engine control system. The developed system controls engine speed based on proportional, integral and derivative (PID) method. This controller is designed to eliminate the need for continuous operator attention on engine revolution control. The control system includes 4 spark coil drivers, fuel drivers and relay drivers to make engine's operating more stable. The experiments of control engine revolution of this system are based on the various load conditions.

  • PDF

동시냉난방 열펌프 시스템의 운전모드별 성능특성에 관한 수치적 연구 (Numerical Study on the Performance Characteristics of a Simultaneous Heating and Cooling Heat Pump System at each Operation Mode)

  • 주영주;정현준;강훈;최종민;이무연;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.370-375
    • /
    • 2007
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this numerical study, a 4-room simultaneous heating and cooling heat pump system was modeled and its performance was calculated at each operating mode. Also, performance analysis was compared with experimental results.

  • PDF

환기시스템이 적용된 히트펌프의 난방시 급기효율 평가에 관한 연구 (A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner with Ventilation System for Heating Season)

  • 권용일;한화택;김경환;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.56-61
    • /
    • 2005
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.