• 제목/요약/키워드: Multi-output inverter

검색결과 126건 처리시간 0.024초

A Novel Auxiliary Edge-Resonant Snubber-Assisted Soft Switching PWM High Frequency Inverter with Series Capacitor Compensated Resonant Load for Consumer Induction Heating

  • Ahmed Nabil A.;Iwai Toshiaki;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제6권2호
    • /
    • pp.95-103
    • /
    • 2006
  • In this paper, a novel prototype of auxiliary switched capacitor assisted voltage source soft switching PWM Single-Ended Push Pull (SEPP) series capacitor compensated load resonant inverter with two auxiliary edge resonant lossless inductor snubbers is proposed and discussed for small scale consumer high-frequency induction heating (IH) appliances. The operation principle of this inverter is described by using switching mode equivalent circuits. The newly developed multi resonant high-frequency inverter using trench gate IGBTs can regulate its output AC power via constant frequency edge-resonant associated soft switching commutation by using an asymmetrical PWM control or duty cycle control scheme. The brand-new consumer IH products which use the newly proposed edge-resonant soft switching PWM-SEPP type series load resonant high-frequency inverters are evaluated using power regulation characteristics, actual efficiency vs. duty cycle and input power vs. actual efficiency characteristics. Their operating performance compared with some conventional soft switching high-frequency inverters for IH appliances is discussed on the basis of simulation and experimental results. The practical effectiveness of the newly proposed soft switching PWM SEPP series load resonant inverter is verified from an application point of view as being suitable for consumer high-frequency IH appliances.

플라잉 커패시터 멀티-레벨 인버터의 플라잉 커패시터 전압 균형을 위한 캐리어 로테이션 기법 (A Carrier-Rotation Strategy for Voltage Balancing of Flying Capacitors in Flying Capacitor Multi-level Inverter)

  • 이원교;김태진;강대욱;현동석
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.469-477
    • /
    • 2003
  • 본 논문은 플라잉 커패시터 멀티-레벨 인버터의 가장 큰 문제점인 플라잉 커패시터 전압 불균형의 새로운 해결방법으로 캐리어 로테이션(Carrier-Rotation) PWM 기법을 제안한다. 제안된 기법은 모든 스위치가 한번의 스위칭동작을 하는 동안 플라잉 커패시터의 충전과 방전에 관계된 레그 전압 리던던시(redundancy)를 같은 비율로 사용하여 플라잉 커패시터 전압을 일정하게 유지하며, 전압의 변동폭이 최소가 되도록 제어한다 이 방법은 각 캐리어의 배치가 모두 통상이므로 출력 전압의 고조파 성분이 저감되며, 또한 모든 스위치의 스위칭 주파수가 같으므로 스위치 이용률이 개선되는 특성을 갖는다. 제안된 기법을 플라잉 커패시터 3-레벨 인버터에 적용하여 상세히 분석하고, 3-레벨 이상에 적용할 수 있도록 일반화한다. 제안된 기법의 타당성은 실험 결과로 검증된다.

대용량 태양광 발전용 멀티센트럴 시스템 (Multi-Central System for Large Scale PV Power Generation)

  • 박종형;고광수;김흥근;노의철;전태원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.427-432
    • /
    • 2012
  • This paper proposes efficient operation method of PV system consisted of multi-central which is suitable for large scale system. The multi-central system used switch at a DC-link and applied proposed algorithm can improve the efficiency and the reliability on the existing system. This algorithm, with advantage of Multi-Central system can minimize the effect of different characteristic of each PV array due to a shadow or damaged PV cell. Each system is analysed and maximum power point tracking control, DC-link voltage control and output current control is used commonly. The validity is verified after comparing of the existing system and proposed system by simulation.

  • PDF

구형파 및 PWM 인버터 조합에 의한 오존발생용 인버터 (The Invert for ozone generator by mixed square_wave and PWM)

  • 박노식;박성준;원태헌;안진우;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1193-1195
    • /
    • 2004
  • Ozone gas is one of the strongest oxidizing and bleaching agents which leave no residues harmful to the global environment. In recent years, the ozone generator has been widely utilized, However, it has been known that a broader application of ozone is hindered primarily because of its low efficiency of generation. Thus, it is more indispensable to improve actual system efficiency of the silent discharge type ozonizer using high frequency inverter. This paper presents a multi level resonant ozone power regulation by association of high frequency transformers and full bridge invert. And proposed resonant inverter system can generate continuous output voltage. can control linearly quantity of ozone gas. This invert that add PWM forms within square forms of output voltage about one level range. The power regulation characteristics and operating performances of silent discharge (SD)type ozone generating tube load driven by this load proposed inverter using FET modules are illustrated from a practical point of view, which can operate under stable conditions of basic level and PWM hybrid control strategy implemented DSP(2406). The effectoveness of propsed invert type ozonizer is proved by experiment results.

  • PDF

LCD 백라이트를 위한 새로운 CCFL 병렬구동 인버터 (A New Current Balancing Methods of CCFL for LCD TV Backlight)

  • 이성주;김호진;이해돈;목형수;최규하;양승욱
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.371-377
    • /
    • 2006
  • CCFL(CCFL: Cold Cathode Fluorescent Lamps, 이하 CCFL로 표기)은 전극이 내부에 존재하는 형태로 그 특성이 일정하지 않아 병렬구동이 어려워 개별 구동을 하고 있다. 본 논문에서는 각 CCFL의 임피던스 차이에 의한 전류오 차를 감소시켜 병렬구동이 가능하도록 구동한다. 제안하는 시스템은 단지 하나의 주 변압기로 동작하며, 다수의 램프를 구동시키기 위해 밸런스 변압기를 적용하여 가격적인이나 용적이 줄어드는 효과를 가져온다. 본 방식의 타당성을 실험 및 시뮬레이션을 통하여 입증하였다.

An Improved SPWM Strategy to Reduce Switching in Cascaded Multilevel Inverters

  • Dong, Xiucheng;Yu, Xiaomei;Yuan, Zhiwen;Xia, Yankun;Li, Yu
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.490-497
    • /
    • 2016
  • The analysis of the switch status of each unit module of a cascaded multi-level inverter reveals that the working condition of the switch of a chopper arm causes unnecessary switching under the conventional unipolar sinusoidal pulse width modulation (SPWM). With an increase in the number of cascaded multilevel inverters, the superposition of unnecessary switching gradually occurs. In this work, we propose an improved SPWM strategy to reduce switching in cascaded multilevel inverters. Specifically, we analyze the switch state of the switch tube of a chopper arm of an H-bridge unit. The redundant switch is then removed, thereby reducing the switching frequency. Unlike the conventional unipolar SPWM technique, the improved SPWM method greatly reduces switching without altering the output quality of inverters. The conventional unipolar SPWM technique and the proposed method are applied to a five-level inverter. Simulation results show the superiority of the proposed strategy. Finally, a prototype is built in the laboratory. Experimental results verify the correctness of the proposed modulation strategy.

A New Cascaded Multilevel Inverter Topology with Voltage Sources Arranged in Matrix Structure

  • Thamizharasan, S.;Baskaran, J.;Ramkumar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1552-1557
    • /
    • 2015
  • The paper unleashes a new idea to arrive at reduced switch count topological structures configured in the form of a matrix for a cascaded Multi level inverter (CMLI). The theory encircles to minimize the number of switches involved in the conduction path and there from acclaim reduced input current distortion, lower switching losses and electromagnetic interference. The focus extends to standardize the number of power devices required for reaching different levels of output voltage from the same architecture. It includes appropriate pulse width modulation (PWM) strategy to generate firing pulses and ensure the desired operation of the power modules. The investigative study carries with it MATLAB based simulation and experimental results obtained using suitable prototypes to illustrate the viability of the proposed concept. The promising nature of the performance projects a new dimension in the use of single phase MLIs for renewable energy related applications.

멀티-스텝 인버터를 이용한 무효전력 보상장치의 고조파 저감 (Reducing the Harmonics of Static Var Compensator Using Multi-Step Inverter)

  • 박현철;김영민;황종선;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.19-22
    • /
    • 2001
  • For stabilization and improving power factor in the power lines, various Static Var Compensators(SVC) have been considered to be installed and partly applicated already. With all these merits of the SVC, it stil has demerits, principally evoking harmonic problems. So far, many harmonic reduction type inverters have been used in various parts. In this paper, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control. The theoretical analysis on this system was confirmed through the computer simulation and the experiments.

  • PDF

상보형(相補形) 트랜지스터에 의한 다중(多重) PWM 인버터에 관한 연구 (A Study on The Multi-PWM Inverter by Complementary Transistor)

  • 정연택;이종수;배상준;백종현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.515-517
    • /
    • 1989
  • This PWM inverter are used bridge circuit of two pair complementary transistor at each phase. The operation signals are 3 level PWM wave of W type and M type modulation, Which were obtained from switching time data by switching position calculation of triangular and sine wave. The output voltage waveforms of this inverter have the 5 level phase voltage and the 9 level line voltage of PWM.

  • PDF

철도차량용 보조전원장치에 관한 연구 (The Study of Auxiliary Power Unit for locomotive)

  • 하인용;이원철;이상석;김태환;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.615-619
    • /
    • 2009
  • There are many increasing demands for efficient high power density of auxiliary power unit(APU) for high speed traction application. Many techniques have been proposed to measure the voltage flicker on the traditional pulse width modulation(PWM) inverter. This paper proposes a novel functionality of the static inverter on the APU to mitigate the voltage flicker and regulate the output voltage. A new control algorithm for the inverter based on the Hilbert transform(HT) is presented. The HT is employed as an effective technique for tracking the voltage flicker levels in APU systems. Simulation results are provided to verify the tracking capabilities of the HT and to evaluate the performance of the proposed DG interface for multi-function operation.

  • PDF