• 제목/요약/키워드: Multi-irradiation

검색결과 143건 처리시간 0.034초

방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구 (Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy)

  • 나수경
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

New Semiconducting Multi-branched Conjugated Molecules Bearing 3,4-Ethylene-dioxythiophene-based Thiophenyl Moieties for Organic Field Effect Transistor

  • Kim, Dae-Chul;Lee, Tae-Wan;Lee, Jung-Eun;Kim, Kyung-Hwan;Cho, Min-Ju;Choi, Dong-Hoon;Han, Yoon-Deok;Cho, Mi-Yeon;Joo, Jin-Soo
    • Macromolecular Research
    • /
    • 제17권7호
    • /
    • pp.491-498
    • /
    • 2009
  • New $\pi$-conjugated multi-branched molecules were synthesized through the Homer-Emmons reaction using alkyl-substituted, 3,4-ethylenedioxythiophene-based, thiophenyl aldehydes and octaethyl benzene-l,2,4,5-tetrayltetrakis(methylene) tetraphosphonate as the core unit; these molecules have all been fully characterized. The two multi-branched conjugated molecules exhibited excellent solubility in common organic solvents and good self-film forming properties. The semiconducting properties of these multi-branched molecules were also evaluated in organic field-effect transistors (OFET). With octyltrichlorosilane (OTS) treatment of the surface of the $SiO_2$ gate insulator, two of the crystalline conjugated molecules, 7 and 8, exhibited carrier mobilities as high as $2.4({\pm}0.5){\times}10^{-3}$ and $1.3({\pm}0.5){\times}10^{-3}cm^2V^{-1}s^{-1}$, respectively. The mobility enhancement of OFET by light irradiation ($\lambda$ = 436 nm) supported the promising photo-controlled switching behavior for the drain current of the device.

격자-강화된 다기능 복합재 구조체의 방사차폐에 관한 연구 (A Study on Radiation Shielding for Grid-stiffened Multi-Functional Composite Structures)

  • 장태성;이주훈;서현석;현범석;김택영;서정기
    • 한국항공우주학회지
    • /
    • 제42권8호
    • /
    • pp.629-639
    • /
    • 2014
  • 강성이 우수하고, 경량으로 제작이 가능한 격자강화 복합재 구조체를 다기능 구조체의 기층구조로 적용함으로써, 전기전자회로를 용이하게 내장할 수 있으며 방사차폐 특성을 갖춘 다기능 구조체에 대한 설계 및 제작을 수행하였다. 피치계열 탄소섬유 복합재료의 적용을 통해 열전달특성을 향상시키고, 전자회로의 하우징 구조물이 없어도 우주방사환경에 충분한 내구성을 갖도록 경량 국부 강화 방사차폐 방법을 제안하고, 양성자 조사시험을 통하여 선택적 방사차폐의 효과를 검증하였다.

하지정맥류 모사 생체조직 팬텀과 조직등가 팬텀을 이용한 초음파 치료효과 평가에 관한 연구 (A Study on the Efficiency Evaluation of Ultrasound Therapy Using Varicose Vein Simulated Tissue Phantom and Tissue Equivalent Phantom)

  • 김주영;정태웅;신경원;노시철;최흥호
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.427-433
    • /
    • 2018
  • 비침습적 치료 효과에 대한 기대로 집속 초음파를 이용한 하지정맥류 치료에 대한 많은 연구가 진행되고 있다. 본 연구에서는 초음파 정맥류 정맥 치료 효과 평가에 적용할 수 있는 생체 조직 팬텀과 조직 등가 팬텀을 제시 하였다. 제작된 팬텀은 음향학적 특징과 초음파 조사에 따른 수축률을 평가함으로써 유용성을 평가하였다. 하지정맥류가 발생하는 조직의 구조를 고려하여 피부, 지방, 근육의 세 층으로 된 다층 구조 팬텀을 제작하였으며, 각 층을 구성하는 물질은 인체와 유사한 특성을 갖도록 제작하였다. 또한 혈관 유사물질을 매식한 다층 구조 팬텀과 동물 혈관을 이용한 다층 구조 팬텀, 동물 조직을 이용한 다층 구조 팬텀을 제작하였으며, 초음파 조사에 따른 혈관 유사 물질 및 혈관 조직의 수축 정도를 B-mode 영상을 이용하여 평가하였다. 본 연구의 결과를 통하여 제시된 팬텀이 초음파 하지정맥류 치료 평가에 유효하게 활용될 수 있을 것으로 판단되었다. 또한, 집속 초음파를 이용한 하지정맥류 치료 장비 개발 및 치료 효과 검증에 중요한 역할을 할 것으로 판단된다.

Multi-scale agglomerates and photocatalytic properties of ZnS nanostructures

  • 만민탄;이홍석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.267.2-267.2
    • /
    • 2016
  • Semiconductor photo-catalysis offers the potential for complete removal of toxic chemicals through its effective and broad potential applications. Various new compounds and materials for chemical catalysts were synthesized in the past few decades. As one of the most important II-VI group semiconductors, zinc sulfide (ZnS) with a wide direct band gap of 3.8 eV has been extensively investigated and used as a catalyst in photochemistry, environmental protection and in optoelectronic devices. In this work, the ZnS films and nanostructures have been successfully prepared by wet chemical method. We show that the agglomerates with four successive scales are always observed in the case of the homogeneous precipitation of zinc sulfide. Hydrodynamics plays a crucial role to determine the size of the largest agglomerates; however, other factors should be invoked to interpret the complete structure. In addition, studies of the photocatalytic properties by exposure to UV light irradiation demonstrated that ZnS nanocrystals (NCs) are good photo-catalysts as a result of the rapid generation of electron-hole pairs by photo-excitation and the highly negative reduction potentials of excited electrons. A combination of their unique features of high surface-to volume ratios, carrier dynamics and rich photo-catalytic suggests that these ZnS NCs will find many interesting applications in semiconductor photo-catalysis, solar cells, environmental remediation, and nano-devices.

  • PDF

Moving Mesh Technique을 이용한 2차원 염해 침투 예측 모델의 개발 (Development of Two Dimensional Chloride Ion Penetration Model Using Moving Mesh Technique)

  • 최원;김한중
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.1-7
    • /
    • 2015
  • Most of chloride diffusion models based on finite difference method (FDM) could not express the diffusion in horizontal direction at each elevation. To overcome these weakness, two dimensional chloride ion penetration model based on finite element method (FEM) to be able to combine various multi-physics simultaneously was suggested by introducing moving mesh technique. To avoid the generation of mesh being able to be distorted depending on the relative movement of water level to static concrete, a rectangular type of mesh was intentionally adopted and the total number of meshes was empirically selected. The simulated results showed that the contents of surface chloride decreased following to the increase of elevation in the top part of low sea level, whereas there were no changes in the bottom part of low level. In the DuraCrete model, the diffusion coefficient of splashed zone is generally smaller than submerged zone, whereas the trend of Life365 model is reverse. Therefore, it could be understood that the developed model using moving mesh technique effectively reflects $DuraCrete^{TM}$ model rather than $Life365^{TM}$ model. In the future, the model will be easily expanded to be combined with various multi-physics models considering water evaporation, heat of hydration, irradiation effect of sun and so on because it is based on FEM.

자외선 조사를 이용한 다단계 컨베이어 자동 살균기 개발에 관한 연구 (The developement of multi-layer sterilizer using Ultra Violet irradiation)

  • 김영철;유광호;정영국;김하석;정태성;윤복선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3060-3063
    • /
    • 1999
  • We made a multi-layer conveyor sterilizing system using UV rays to prolong a storage period of dried marine products. The system is composed of 5 layer conveyor belt of 3 m long each, thus 15 m long in total. It is designed to radiate UV rays for 10 minutes the dried marine products, and can process 300 kg/hour. Eight UV lamps of 30 cm long and 15 W of power with 254 nm wave length are installed in parallel, 15 cm high above in each belt, and 40 lamps in total. The whole system is covered by 1 mm thick metal plates to block the UV rays except a front side which is covered with 5 mm thick plastic plates coated with UV protection film to survey inside of the system. A sterile ratio is about 99.97% with 10 minutes sterilization using this system.

  • PDF

Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target

  • Lim, Soobin;Kim, Donghwan;Kang, Jin-Goo;Dang, Jeong-Jeung;Lee, Pilsoo;Kim, Geehyun;Chung, Kyoung-Jae;Hwang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.437-441
    • /
    • 2022
  • In this study, we developed a neutron time-of-flight (nTOF) measurement system for a 1.7-MV tandem proton accelerator with a target covered with 300-nm-thick lithium (Li) layer. With implementation of beam chopping module after its ion source, the accelerator is configured to operate in pulsed-beam mode with a pulse width <50 ns at 20-kHz repetition rate. This enables the gamma flash-type nTOF measurement system to identify the neutron generated with 3-MeV proton beam energy. The nTOF system consists of a 30" cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. The nTOF system successfully measured the generated neutron energy at irradiated proton energies of 2.6 and 3.0 MeV with an average energy resolution of 15%.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

Preparation of Crystalline $Si_{1-x}Ge_x$ Thin Films by Pulsed Ion-Beam Evaporation

  • Yang, Sung-Chae
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권4호
    • /
    • pp.181-184
    • /
    • 2004
  • Thin films of single phase, polycrystalline silicon germanium (Si$_{1-x}$ Ge$_{x}$) were prepared by ion-beam evaporation (IBE) using Si-Ge multi-phase targets. After irradiation of the targets by a pulsed light ion beam with peak energy of 1 MV, 450 and 480 nm thick films were deposited on Si single crystal and quartz glass substrates, respectively. From XRD analysis, the thin films consisted of a single phase Si$_{1-x}$ Ge$_{x}$, whose composition is close to those of the targets.rgets.