Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Measurement System: Pilot Study

  • Kim, Jaehyung;Shin, Beumjoo;Jeon, Gyerok
    • Journal of information and communication convergence engineering
    • /
    • 제15권2호
    • /
    • pp.123-130
    • /
    • 2017
  • The early detection of intravenous (IV) infiltration is necessary to minimize the injury caused by the infiltration, which is one of the most important tasks for nurses. For detecting early infiltration in patients receiving invasive vein treatment, bioelectrical impedance was measured using multi-frequency bioelectrical impedance. The impedance decreased significantly at infiltration, and then decreased gradually over time after infiltration. The relative impedance at 20 kHz decreased remarkably at infiltration, and then gradually decreased thereafter. In addition, the impedance ratio increased temporarily at infiltration and then gradually decreased over time. Furthermore, the impedance at each frequency decreased quantitatively over time. This indicates that IV solution leaking from the vein due to infiltration accumulates in the subcutaneous tissues. Moreover, slopes of log Z vs. log f differently decreased with increasing log f, indicating that the impedance exhibits different responses depending on the frequency.

Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method

  • Kim, J.H.;Jang, W.Y.;Kim, S.S.;Son, J.M.;Park, G.C.;Kim, Y.J.;Jeon, G.R.
    • 센서학회지
    • /
    • 제23권6호
    • /
    • pp.368-376
    • /
    • 2014
  • In order to measure the segmental impedance of the body, a bioelectrical impedance measurement system (BIMS) using multi-frequency applying method and two-electrode method was implemented in this study. The BIMS was composed of constant current source, automatic gain control, and multi-frequency generation units. Three experiments were performed using the BIMS and a commercial impedance analyzer (CIA). First, in order to evaluate the performance of the BIMS, four RC circuits connected with a resistor and capacitor in serial and/or parallel were composed. Bioelectrical impedance (BI) was measured by applying multi-frequencies -5, 10, 50, 100, 150, 200, 300, 400, and 500 KHz - to each circuit. BI values measured by the BIMS were in good agreement with those obtained by the CIA for four RC circuits. Second, after measuring BI at each frequency by applying multi-frequency to the left and right forearm and the popliteal region of the body, BI values measured by the BIMS were compared to those acquired by the CIA. Third, when the distance between electrodes was changed to 1, 3, 5, 7, 9, 11, 13, and 15 cm, BI by the BIMS was also compared to BI from the CIA. In addition, BI of extracellular fluid (ECF) was measured at each frequency ranging from 10 to 500 KHz. BI of intracellular fluid (ICF) was calculated by subtracting BI of ECF measured at 500 kHZ from BI measured at seven frequencies ranging from 50 to 500 KHz. BI of ICF and ECF decreased as the frequency increased. BI of ICF sharply decreased at frequencies above 300 KHz.

Simulations of Frequency-dependent Impedance of Ground Rods Considering Multi-layered Soil Structures

  • Lee, Bok-Hee;Joe, Jeong-Hyeon;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.531-537
    • /
    • 2009
  • Lightning has a broad frequency spectrum from DC to a few MHz. Consequently, the high frequency performance of grounding systems for protection against lightning should be evaluated, with the distributed parameter circuit model in a uniform soil being used to simulate grounding impedances. This paper proposes a simulation method which applies the distributed parameter circuit model for the frequency-dependent impedance of vertically driven ground rods by considering multi-layered soil structures where ground rods are buried. The Matlab program was used to calculate the frequency-dependent ground impedances for two ground rods of different lengths. As a result, an increase of the length of ground rod is not always followed by a decrease of grounding impedance, at least at a high frequency. The results obtained using the newly proposed simulation method considering multi-layered soil structures are in good agreement with the measured results.

웨이블릿 변환 기반 시간-주파수 영역 반사파 계측법을 이용한 활선 상태 전력 케이블의 중복 임피던스 변화 지점 추정 (Multi-Impedance Change Localization of the On-Voltage Power Cable Using Wavelet Transform Based Time-Frequency Domain Reflectometry)

  • 이신호;최윤호;박진배
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.667-672
    • /
    • 2013
  • In this paper, we propose a multi-impedance changes localization method of on-voltage underground power cable using the wavelet transform based time-frequency domain reflectometry (WTFDR). To localize the impedance change in on-voltage power cable, the TFDR is the most suitable among reflectometries because the inductive coupler is used to inject the reference signal to the live cable. At this time, the actual on-voltage power cable has multi-impedance changes such as the automatic section switches and the auto load transfer switches. However, when the multi-impedance changes are generated in the close range, the conventional TFDR has the cross term interference problem because of the nonlinear characteristics of the Wigner-Ville distribution. To solve the problem, the wavelet transform (WT) is used because it has the linearity. That is, using WTFDR, the cross term interference is not generated in multi-impedance changes due to the linearity of the WT. To confirm the effectiveness and accuracy of the proposed method, the actual experiments are carried out for the on-voltage underground power cable.

12채널 Multi-frequency를 이용한 경혈 임피던스 측정시스템 개발 및 평가 (Development & Evaluation of acupuncture Point Impedance Measurement System Using 12 Channels Multi-Frequency)

  • 김수병;이재우;이승욱;이나라;김영대;신태민;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제28권1호
    • /
    • pp.1-13
    • /
    • 2011
  • Objectives : The object of this study is to evaluate and develop the system that reflects acupoints electrical properties by the multi-frequency using the SPAC (Single Power Alternative Current) stimulation method based on BIA (Bioelectrical impedance method). Methods : The 12 channel meridian impedance measurement system (MIMS) was designed, which sets multi-frequency with 10 steps (1~10kHz). To check acupoints electrical properties, impedance of acupoints were measured from 11 acupoints selected from the LU and ST meridians. Results : Regarding distribution of measurement values by multi-frequencies, we found the lowest response at 1kHz was in common. But frequency bands which represent the highest response at each acupoint were various. Measurement values of each acupoint by multi-frequencies were expressed similar distribution (P<0.05). Also we could check same frequency band which showed the highest response at left/right equal acupoints (P<0.05). Conclusions : Through change of acupoints electrical properties by multi-frequency stimulation, we checked oriental medical diagnostic possibilities by using this system. We would progress variable clinical trials with this system for oriental medical diagnosis.

비만관련 생활습관병 위험인자 예측을 위한 다중 주파수 기반의 분할 체임피던스 측정법 (The Novel Method of Segmental Bio-Impedance Measurement Based on Multi-Frequency for a Prediction of risk Factors Life-Style Disease of Obesity)

  • 김응석;노연식;서광석;박성빈;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.375-384
    • /
    • 2010
  • The purpose of this study is to determine whether there is a correlation between the segmental bio-impedance measurement with the frequency modulations and the life-style disease of obesity. An obesity is not simply the factor for estimating the life-style disease of obesity, but also the risk factor occurring. There are many methods (BMI, WHR, Waist, CT, DEXA, BIA, etc.) for measuring a degree of obesity; the bio-impedance measurement is more economic and more effective than others. The physical examination, the blood test, the medical imaging diagnosis and the bio-impedancemeasurementswithmultiple frequencies for each body parts have been conducted for 77 people. The estimated value has been calculated through a segmental bio-impedance model based on multi-frequency that was created to reflect the highest correlation by analyzing correlation with linear regression analysis method for the measured bio-impedance and the risk factors. Then we compared with the clinical diagnosis. In case of high level cholesterol, low HDL-C and high LDL-C for life-style disease, the sensitivity is 80~100%and the specificity is 83~100%. This study has shown conclusively that bio-impedance can be a possible predictor to analyze the disease risk rate of population and individual health maintenance. And also the multi-frequency segmental bio-impedance can be used as early predictor to estimate the life-style disease of obesity.

Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰 (Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results)

  • 김수병;이나라;이승욱;최준영;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

Electrical Impedance Tomography and Biomedical Applications

  • Woo, Eung-Je
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.1-6
    • /
    • 2007
  • Two impedance imaging systems of multi-frequency electrical impedance tomography (MFEIT) and magnetic resonance electrical impedance tomography (MREIT) are described. MFEIT utilizes boundary measurements of current-voltage data at multiple frequencies to reconstruct cross-sectional images of a complex conductivity distribution (${\sigma}+i{\omega}{\varepsilon}$) inside the human body. The inverse problem in MFEIT is ill-posed due to the nonlinearity and low sensitivity between the boundary measurement and the complex conductivity. In MFEIT, we therefore focus on time- and frequency-difference imaging with a low spatial resolution and high temporal resolution. Multi-frequency time- and frequency-difference images in the frequency range of 10 Hz to 500 kHz are presented. In MREIT, we use an MRI scanner to measure an internal distribution of induced magnetic flux density subject to an injection current. This internal information enables us to reconstruct cross-sectional images of an internal conductivity distribution with a high spatial resolution. Conductivity image of a postmortem canine brain is presented and it shows a clear contrast between gray and white matters. Clinical applications for imaging the brain, breast, thorax, abdomen, and others are briefly discussed.

  • PDF

다주파수 임피던스 단층촬영 시스템 (Multi-Frequency Electrical Impedance Tomography System)

  • 오동인;조성필;김상민;구환;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.66-74
    • /
    • 2007
  • We have developed a multi-channel, multi-frequency EIT system with operating frequency of 10Hz to 500KHz. The number of digital voltmeters using phase-sensitive demodulation can be varied from 8 to 64 and we found that 16 and 32-channels are most practical. This paper describes the design, implementation, and construction of 16 and 32-channel systems. The performance of the system was thoroughly tested and we found that CMRR of the developed voltmeter is about 85dB with $100{\Omega}$ unbalancing series resistor. The SNR is greater than 99.6dB and the output impedance of the constant current source is $1{\Omega}W$ at least for all frequencies. Imaging experiments using a banana with frequency-dependent conductivity and permittivity show that frequency-difference imaging is possible using the developed system. Future works of animal and human experiments are discussed.

SIR 공진기를 이용한 적층형 필터/듀플렉서 설계 (A design of a multi-layer filter/duplexer using stepped impedance resonator)

  • 이종훈;김영태;강병권;정명섭;박준석;임재봉
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.169-172
    • /
    • 2002
  • In this paper, the design formulas for bandpass filters using parallel coupled stepped impedance resonators(SIR) are derived. General content about basic feature of stepped impedance resonators(SIR) is represented. The filters and duplexer using stepped impedance resonators(SIR) have been designed and realized with the presented design method at IMT-2000 frequency band Simulations have used serenade circuit simulation and HFSS EM-simulation. We were showed excellent agreements between SIR design theory and simulation results on the multi-layer filter/duplexer.

  • PDF