1 |
N. E. Soifer, S. Borzak, and B. R. Edlin, "Prevention of peripheral venous catheter complications with an intravenous therapy team: a randomized controlled trial," Archives of Internal Medicine, vol. 158, no. 5, pp. 473-477, 1998.
DOI
|
2 |
C. M. Rickard, J. Webster, M. C. Wallis, N. Marsh, M. R. McGrail, V. French et al., "Routine versus clinically indicated replacement of peripheral intravenous catheters: a randomized controlled equivalence trial," Lancet, vol. 380, no. 9847, pp. 1066-1074, 2012.
DOI
|
3 |
J. Webster, S. Osborne, C. Rickard, and J. Hall, "Clinicallyindicated replacement versus routine replacement of peripheral venous catheters," Cochrane Database of Systematic Reviews, vol. 17, no. 3, article ID. CD007798, 2010.
|
4 |
Infusion Nurse Society, "Infusion nursing standards of practice," Journal of Infusion Nursing, vol. 29, S1-S92, 2006.
DOI
|
5 |
R. Clifton-Koeppel, "Wound care after peripheral intravenous extravasation: what is evidence?" Newborn and Infant Nursing Reviews, vol. 6, pp. 202-211, 2006.
DOI
|
6 |
L. Hadaway "Infiltration and extravasation," American Journal of Nursing, vol. 107, no. 8, pp. 61-72, 2007.
|
7 |
J. L. Thigpen, "Peripheral intravenous extravasation: Nursing procedure for initial treatment," Neonatal Network, vol. 26, no. 6, pp. 379-384, 2007.
DOI
|
8 |
M. M. Pollack, "Intravenous infiltration detection," U.S. Patent 20130131506 A1, Nov. 18, 2011.
|
9 |
S. Doinger, P. Ishimine, J. C. Fox, and J. T. Kanegaye, "Randomized controlled trial of ultrasound-guided peripheral intravenous catheter placement versus traditional techniques in difficult-access pediatric patients," Pediatric Emergency Care, vol. 25, no. 3, pp. 154-159, 2009.
DOI
|
10 |
F. Magnarelli, "IV Infiltration Detector," 2013 [Internet]. Available: http://contest.techbriefs.com/2013/entries/medical/3251.
|
11 |
L. W. Winchester and N. Y. Chou, "Optical detection of intravenous infiltration," in Advanced Biomedical and Clinical Diagnostic Systems IV, Proceedings of the SPIE vol. 6080. Bellingham, WA: SPIE, 2006.
|
12 |
N. Y. Chou, L .W. Winchester, W. J. Naramore, M. S. Alley, and A. J. Lesnick, "An optical device for detecting intravenous infiltration," 2006 [Internet]. Available: http://www.ivteam.com/ optical-iv.pdf.
|
13 |
H. C. Lukaski, P. E. Johnson, W. W. Bolonchuk, and G. I. Lykken, "Assessment of fat-free mass using bioelectrical impedance measurement of the human body," American Journal of Clinical Nutrition, vol. 41, no. 4, pp. 810-817, 1985.
DOI
|
14 |
H. C. Lukaski, "Biological indexes considered in the derivation of the bioelectrical impedance analysis," American Journal of Clinical Nutrition, vol. 64, no. 3, pp. 397S-404S, 1996.
DOI
|
15 |
M. S. Mialich, J. M. F. Sicchieri, and A. A. J. Junior, "Analysis of body composition: a critical review of the use of bioelectrical impedance analysis," International Journal of Clinical Nutrition, vol. 2, no. 1, pp. 1-10, 2014.
|
16 |
S. F. Khalil, M. S. Mohktar, and F. Ibrahim, "The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases," Sensors, vol. 14, no. 6, pp. 10895-10928, 2014.
DOI
|
17 |
L. C. Ward, "Segmental bioelectrical impedance analysis: an update," American Journal of Clinical Nutrition, vol. 15, no. 5, pp. 424-429, 2012.
|
18 |
C. Pichonnaz, J. P. Bassin, E. Lecureux, D. Currat, and B. M. Jolles, "Bioimpedance spectroscopy for swelling evaluation following total knee arthroplasty: a validation study," BMC Musculoskeletal Disorders, vol. 16, article no. 100, 2015.
|
19 |
D. B. Stroud, B. H. Cornish, B. J. Thomas, and L. C. Ward, "The use of Cole-Cole plots to compare two multi-frequency bioimpedance instruments," Clinical Nutrition, vol. 14, no. 5, pp. 307-311, 1995.
DOI
|
20 |
S. Grimnes and O. G. Martinsen, Bioimpedance and Bioelectricity Basics, 2nd ed. Oxford: Elsevier, 2008.
|
21 |
F. Zhu, E. F. Leonard, and N. W. Levin, "Body composition modeling in the calf using an equivalent circuit model of multifrequency bioimpedance analysis," Physiological Measurement, vol. 26, no. 2, pp. S133-S143, 2005.
DOI
|
22 |
J. H. Kim, S. S. Kim, S. H. Kim, S. W. Baik, and G. R. Jeon, "Bioelectrical impedance analysis at popliteal regions of human body using BIMS," Journal of Sensor Science & Technology, vol. 25, no. 1, pp. 1-7, 2016.
DOI
|
23 |
S. M. Weinstein, Plumer's Principles & Practice of Intravenous Therapy, 7th ed. Philadelphia, PA: Lippincott Williams & Wilkins, 2001.
|
24 |
B. C. Kim, C. M. Kim, and C. H. Lee, "Multi-channel impedance measuring method and multi-channel impedance measuring instrument," WO 2014035040 A1 (PCT/KR2013/005779), Jun. 28, 2013.
|
25 |
U. Mulasi, A. J. Kuchnia, A. J. Cole, and C. P. Earthman, "Bioimpedance at the bedside: current applications, limitations, and opportunities," Nutrition in Clinical Practice, vol. 30, no. 2, pp. 180-193, 2015.
DOI
|
26 |
I. Haapala, A. Hirvonen, L. Niskanen, M. Uusitupa, H. Kroger, E. Alhava, and A. Nissinen, "Anthropometry, bioelectrical impedance and dual-energy X-ray absorptiometry in the assessment of body composition in elderly Finnish women," Clinical Physiology and Functional Imaging, vol. 22, no. 6, pp. 383-391, 2002.
DOI
|
27 |
S. M. Park, I. S. Jeong, K. L. Kim, K. J. Park, M. J. Jung, and S. S. Jun, "The effect of intravenous infiltration management program for hospitalized children," Journal of Pediatric Nursing, vol. 31, no. 2, pp. 172-178, 2016.
DOI
|
28 |
B. F. Tofani, S. A. Rineair, C. H. Gosdin, P. M. Patricia, S. McGee, K. R. Varadarajan, and P. J. Schoettker, "Quality improvement project to reduce infiltration and extravasation events in a pediatric hospital," Journal of Pediatric Nursing, vol. 27, no. 6, pp. 682-689. 2012.
DOI
|
29 |
L. C. Ward, K. Sharpe, D. Edgar, V. Finlay, and F Wood, "Measurement of localized tissue water - clinical application of bioimpedance spectroscopy in wound management," Journal of Physics: Conference Series, vol. 434, pp. 012043, 2013.
DOI
|