• Title/Summary/Keyword: Multi-device

Search Result 1,602, Processing Time 0.04 seconds

Operating System Design of Multi Beam Control System with Miniaturized Electron Beam Columns (초소형 전자빔을 이용한 멀티 전자빔 운영 시스템 설계)

  • Lim, Sun Jong;Kim, Ho Seob
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.12-16
    • /
    • 2015
  • The research on multi electron beam systems is being carried out by various methods. We are studying multi electron beam system using miniaturized electron beam columns. The column consists of electrostatic lenses, electrostatic deflector and tip emitter. Our operating system controls 4 column array, captures images of each column and maintains the instrument. We present the usefulness of our operating system for multi columns by capturing images of each column.

Energy efficient Medium Access Control for multi-hop sensor network (멀티-홉 센서 네트워크 저전력 MAC 설계)

  • Gang, Jeong-Hun;Lee, Min-Gu;Park, Byeong-Ha;Yu, Jun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.279-282
    • /
    • 2003
  • This paper proposes a medium-access control(MAC) protocol designed for wireless multi-hop sensor networks which is used for connecting physical world and cyber computing space. Wireless multi-hop sensor networks use battery-operated computing and sensing device. We expect sensor networks to be deployed in an ad hoc fashion, with nodes remaining inactive for long time, but becoming suddenly active when specific event is detected. These characteristics of multi-hop sensor networks and applications motivate a MAC that is different from traditional wireless MACs about power conservation scheme, such as IEEE 802.11. Proposed MAC uses a few techniques to reduce energy consumption. Result show that proposed MAC obtains more energy sayings.

  • PDF

A Study on the MPPT Control Method for Grid-connected Multi-String Three-Phase Three-Level PV Inverter (계통연계형 멀티스트링 3상 3레벨 태양광 인버터의 MPPT 제어방법에 관한 연구)

  • Kim, Jinsoo;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.43-48
    • /
    • 2014
  • Two-level inverter has some disadvantages like high harmonics contained in the output current, efficiency limit and stress to switching device as IGBT and FET. Many researches have reported multi-level inverter to complement two-level inverter of problems. In this paper, we suggest MPPT algorithm of multi-string three-level solar inverter that considered nowadays. We added midpoint controller in order to implement the MPPT algorithm because the three-level inverter has to need midpoint controller and procured the stability of direct current link. We verify the superiority of multi-string T-Type inverter and the algorithm we suggested with solar irradiance variation experiment and MPPT efficiency measurement. The MPPT efficiency was confirmed with a high efficiency more than 99.97%.

Power Quality Improvement in Autonomous Microgrids Using Multi-functional Voltage Source Inverters: A Comprehensive Review

  • Miveh, Mohammad Reza;Rahmat, Mohd Fadli;Ghadimi, Ali Asghar;Mustafa, Mohd Wazir
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1054-1065
    • /
    • 2015
  • Multi-functional voltage source inverters (VSIs) have attracted increasing attention in recent years for their advantageous auxiliary services for power quality enhancement in autonomous microgrids. These types of VSIs can not only achieve a proper control scheme in autonomous mode but also cope with the prescribed power quality and stability requirements. These functionalities are integrated within the same device, thereby significantly improving the cost-effectiveness of microgrids while decreasing the investment and bulk compared with those of multiple devices with independent functionalities. Control strategies for power quality enhancement in autonomous microgrids using multi-functional VSIs are comprehensively reviewed in this paper. In addition, such VSIs are discussed in detail, and comparisons of which are also provided. Lastly, a number of future research directions for multi-functional VSIs are recommended.

Dynamic Association and Natural Interaction for Multi-Displays Using Smart Devices (다수의 스마트 디바이스를 활용한 멀티 디스플레이 동적 생성 및 인터랙션)

  • Kim, Minseok;Lee, Jae Yeol
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.4
    • /
    • pp.337-347
    • /
    • 2015
  • This paper presents a dynamic association and natural interaction method for multi-displays composed of smart devices. Users can intuitively associate relations among smart devices by shake gestures, flexibly modify the layout of the display by tilt gestures, and naturally interact with the multi-display by multi-touch interactions. First of all, users shake their smart devices to create and bind a group for a multi-display with a matrix configuration in an ad-hoc and collaborative situation. After the creation of the group, if needed, their display layout can be flexibly changed by tilt gestures that move the tilted device to the nearest vacant cell in the matrix configuration. During the tilt gestures, the system automatically modifies the relation, view, and configuration of the multi-display. Finally, users can interact with the multi-display through multi-touch interactions just as they interact with a single large display. Furthermore, depending on the context or role, synchronous or asynchronous mode is available to them for providing a split view or another UI. We will show the effectiveness and advantages of the proposed approach by demonstrating implementation results and evaluating the method by the usability study.

Human and organizational factors for multi-unit probabilistic safety assessment: Identification and characterization for the Korean case

  • Arigi, Awwal Mohammed;Kim, Gangmin;Park, Jooyoung;Kim, Jonghyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.104-115
    • /
    • 2019
  • Since the Fukushima Daiichi accident, there has been an emphasis on the risk resulting from multi-unit accidents. Human reliability analysis (HRA) is one of the important issues in multi-unit probabilistic safety assessment (MUPSA). Hence, there is a need to properly identify all the human and organizational factors relevant to a multi-unit incident scenario in a nuclear power plant (NPP). This study identifies and categorizes the human and organizational factors relevant to a multi-unit incident scenario of NPPs based on a review of relevant literature. These factors are then analyzed to ascertain all possible unit-to-unit interactions that need to be considered in the multi-unit HRA and the pattern of interactions. The human and organizational factors are classified into five categories: organization, work device, task, performance shaping factors, and environmental factors. The identification and classification of these factors will significantly contribute to the development of adequate strategies and guidelines for managing multi-unit accidents. This study is a necessary initial step in developing an effective HRA method for multiple NPP units in a site.

Properties evaluation for ESD Protection device of Diode type using TLP evaluation method (TLP 평가기법을 이용한 Diode type의 ESD 보호소자 특성 평가)

  • Lee, Tae-Il;Kim, Hong-Bae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.53-57
    • /
    • 2007
  • In paper, We evaluated for various diode type ESD protection device using TLP measurement method. An Evaluation diode is divided to Enclosed type and Stripe type as pattern style in extensive. These diodes is split up followed factor that Anode-to-Cathod space, N+ region width, Multi type and Contact to Active space. After a TLP measurement, we can be got the Vt2, It2 by I-V characteristic values. In the results, diode of enclosed type is present relatively higher Current capability(It2) than stripe type in a same voltage conditions. And the Second-breakdown voltage(Vt2) were that Stripe type's diode higher than Enclosed type's diode as have $14{\sim}15V$. Finally we suggest the best diode design condition as ESD protection device using entire consequence.

  • PDF

mSROS : Real-Time Operating System for Device Controller System in ATM Switching Systems (mSROS : ATM 교환기 장치 제어계를 위한 실시간 운영체제)

  • 김형환;정부금
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.285-288
    • /
    • 1998
  • In this paper, we present mSROS(Micro-Scalable Realtime Operating System) to be applied commonly to the device controller systems in the HANbit ACE256 system. The device controller systems in HANbit ACE256 system are organized as many kinds of device controller. Applying modified PPOS(Peripheral Processor Operating System)which is an operating system for devices of the TDX-10 switching system to the firmwares for them, the inefficiency in development and maintenance exists inherently. To remove the inefficiency nd to improve the performqance of firmwares, we build a common operating system platform that including multi-tasking microkernel so that the firmwares among devices can acquire convenient development and cheap cost of maintencance. Especially, building a virtual machine as a development methodology, it is possible to remove dependency from the kernel so that any kinds of commercial real-time kernels can be used in mSROS as a basic kernel. The virtual machine in mSROS is compatible with the API of SROS(Scalable Realtime Operating System), PPOS, and CROS(Concurrent Realtime Operating System).

  • PDF

An Experimental Study on the Performance of a Heat Pump with a Refrigerant Heating Device (냉매가열식 열펌프시스템의 성능특성에 관한 실험적 연구)

  • Kim, Sang-Hyuk;Park, Youn-Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.707-713
    • /
    • 2006
  • To improve heating performance of the heat pump in winter season, refrigerant heating device was applied to conventional heat pump. The refrigerant heating device operates at the heating capacity does not enough to the heating load requirement of the conditioning space. When the discharge air temperature of the indoor heat exchanger goes down to below $40^{\circ}C$ which is criterion for comfort of the occupants in the conditioning space, the system also starts. The refrigerant heating system has new concept of auxiliary heating device for heat pump in winter. In this study, the system performance was analyzed through experiments and parametric study was conducted to improve the COP and control strategies.

Development of Component of Micro Thermal Device in KAIST (KAIST의 마이크로 열기관 요소 기술 개발)

  • Lee, Dae Hoon;Park, Dae-Eun;Yoon, Euisil;Kwon, Sejin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.482-485
    • /
    • 2002
  • Development projects in KAIST rotted to the micro thermal device is introduced. Multi disciplinary research team is composed by combustion group and semiconductor group in KAIST and catalyst research center in KRICT to develop micro thermal/fluidic device and various items are on development. Among the projects, various kind of componenst that is required by the micro thermal devicesystem is introduced. Technology related to development of micro combustor, Micro igniter, micro fabrication of 3D structure, micro reactor and micro catalyst preparation is introduced.

  • PDF