• Title/Summary/Keyword: Multi-criteria

Search Result 1,066, Processing Time 0.033 seconds

Optimal Configuration of the Truss Structures by Using Decomposition Method of Three-Phases (3단계(段階) 분할기법(分割技法)에 의한 평면(平面)트러스 구조물(構造物)의 형상(形狀) 최적화(最適化)에 관한 연구(硏究))

  • Lee, Gyu Won;Song, Gi Beom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.39-55
    • /
    • 1992
  • In this research, a Three Level Decomposition technique has been developed for configuration design optimization of truss structures. In the first level, as design variables, behavior variables are used and the strain energy has been treated as the cost function to be maximized so that the truss structure can absorb maximum energy. For design constraint of the optimal design problem, allowable stress, buckling stress, and displacement under multi-loading conditions are considered. In the second level, design problem is formulated using the cross-sectional area as the design variable and the weight of the truss structure as the cost function. As for the design constraint, the equilibrium equation with the optimal displacement obtained in the first level is used. In the third level, the nodal point coordinates of the truss structure are used as coordinating variable and the weight has been taken as the cost function. An advantage of the Three Level Decomposition technique is that the first and second level design problems are simple because they are linear programming problems. Moreover, the method is efficient because it is not necessary to carry out time consuming structural analysis and techniques for sensitivity analysis during the design optimization process. By treating the nodal point coordinates as design variables, the third level becomes unconstrained optimal design problems which is easier to solve. Moreover, by using different convergence criteria at each level of design problem, improved convergence can be obtained. The proposed technique has been tested using four different truss structures to yield almost identical optimum designs in the literature with efficient convergence rate regardless of constraint types and configuration of truss structures.

  • PDF

Modified QuEChERS Multi-Residue Analysis Method for 61 pesticides in Fruits using with HPLC and GC-ECD/NPD (HPLC 및 GC-ECD/NPD를 이용한 과일 중 61종 농약의 QuEChERS 전처리 다성분 분석법 개발)

  • Lee, Ju-Young;Hong, Su-Myeong;Kim, Taek-Kyum;Min, Zaw Win;Kim, Yang-Hyeon;Song, Kyung-Ae;Kwon, Hye-Yong;Lee, Hee-Dong;Im, Geon-Jae;Kim, Doo-Ho;Kim, Jang-Eok
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.242-256
    • /
    • 2012
  • QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method has been a lot of research for pesticide analysis, because it is very simple and fast. However, this method requires high sensitivity instrument such as LC-MS/MS because of the use of small sample volume and many impurities compared to the conventional method. So, QuEChERS method needs to be modified for using with HPLC and GC-ECD/NPD. The aim of this work was to study the application of the QuEChERS method as well as its modification for the extraction and preconcentration of 5 groups of 61 pesticides from 4 fruits prior to their determination by HPLC-PDA, GC-ECD/NPD, and LC-MS/MS. The method was validated using spiking levels at 0.1 mg/kg (or 0.01 mg/kg) in apple, grapes, pear and persimmon. The average recovery by QuEChERS AOAC Official 2007. 01 version using the LC-MS/MS varied from 71.1127.4% for 61 pesticides. The average recovery rates using modified QuEChERS varied from 70.9~126% for 61 pesticides by HPLC-PDA and GC-ECD/NPD. The results satisfied the criteria of multiple pesticide residue analysis, setting 70~130% for recovery rates and below 30% for CV.

Characteristics of Intrusion MO and Perception of Target Hardening of Burglars (침입절도범 재소자의 수법 특성과 타겟하드닝 관련 인식)

  • Park, Hyeonho;Kim, Kang-Il;Kim, Hyo-gun
    • Korean Security Journal
    • /
    • no.60
    • /
    • pp.33-61
    • /
    • 2019
  • It is quite difficult to actually prove the effectiveness of so-called target-hardening, one of the various strategies used to reduce crime, one of the serious problems in society recently. In particular, three to five minutes is often used as golden time for intruders to give up or stop, which is based on foreign and some indirect research cases in Korea, but there were no studies that more directly identified the average break-in operation time or the abandonment time based on the elapsed time when the shield hardware resists intruders. This study was the first of its kind in Korea to investigate and verify samples of 90 inmates of break-in burglars who were imprisoned in August 2018 by profiling the average criminal experience, education level, age, height and weight of typical Korean professional break-in thieves, and specific criminal methods, average break-in operation time, and the criteria for giving up if not breached. According to the analysis results, in the survey on the number of pre-invasion theft crimes by intruders, many of the respondents who participated in the survey were criminals of professional invasions, and by their physical characteristics, there was not much difference from ordinary adult men. Residential facilities were the highest in the world, followed by commercial and educational facilities. According to the survey on the types of facilities that committed intrusion into residential facilities, it was not safe to say that single-family housing accounted for the largest portion of single-family housing, multi-family housing, apartment high-rise (more than three stories), and apartment low-rise (more than one to three stories) among residential facilities, and that the ratio of apartment high-rise was higher than expected. Based on the average time required to break into a place for an intrusion crime, it is assumed that the psychological time worked in a place where the break-in was difficult, since the break-in was not performed while measuring the time of the break-in operation. In the case of time to give up a crime, more than half of the respondents said they would give up the crime even in less than four minutes, suggesting that a significant number of intrusive crimes can be prevented even if the facility has four minutes of intrusion resistance. This proves that most intruders will give up the break-in if the break-in resistance performance of the security facility is exercised for more than five minutes.

Freshwater Fish Fauna and Ecological Health Assessment of the Agricultural Reservoirs in Jecheon City, Korea (제천시 농업용저수지의 어류상 및 생태건강성평가)

  • Han, Jeong-Ho;Kim, Jae Hwan;Lee, Sang-Bo;Paek, Woon-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.3
    • /
    • pp.307-321
    • /
    • 2018
  • Fish fauna and lentic ecosystem health assessment in freshwater were analyzed in the two reservoirs (Uirim Reservoir(Ur) and Solbangjuk Reservoir(Sr)) of the Jecheon City during May-September 2017. Total numbers of the species and genus (7 family) sampled were 21 and 16, respectively. Cyprinidae was most dominant taxa, which accounted for 11 species (52.4%) of the total species, and the relative abundance, based on the number of individuals, was 318 individuals (46.2%). Subdominant families were taxa of Centrachidae (2 species; 264 ind. (38.4%). The dominant species, based on the relative abundance, were Squalidus chankaensistsuchigae(22.7%). Subdominant species were Lepomis macrochirus(19.5%, 134 ind.) and Micropterus salmoides(18.9%, 134 ind.). Trophic state index of Korea ($TSI_{KO}$), based on chemical oxygen demand (COD), total phosphorus (TP) and chlorophyll-a (CHL),ranged mesotrophic state. The purpose of this study was to apply a multi-metric model of Lentic Ecosystem Health Assessments (LEHA) for environmental impact assessments of two reservoirs and assessed the ecological health model values. Trophic composition's metrics showed that tolerant species (56.8%, 98.3%) and omnivore species (43.9%, 65.6%) dominated the fish fauna in the two reservoirs (Ur and Sr) of Jecheon City, indicating a biological degradation in the aquatic ecosystem. The relative proportions of Micropterus salmoides, also showed greater than 16.3% (Ur), 31.1% (Sr) of the total, indicating a ecological disturbance. The average value of LEHA model was 22 (Ur) and 12 (Sr) in the reservoirs, indicating a "poor condition (Ur)" and "very poor condition (Sr)" by the criteria of MOE (2014).

Stream Ecosystem Assessments, based on a Biological Multimetric Parameter Model and Water Chemistry Analysis (생물학적 다변수 모델 적용 및 수화학 분석에 의거한 갑천생태계 평가)

  • Bae, Dae-Yeul;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.198-208
    • /
    • 2006
  • This research was to apply a multi-metric approach, so called the Index of Biological Integrity (IBI) as a tool for biological evaluations of water environments, to a wadable stream. For the study, we surveyed 5 sampling locations in Kap Stream during August 2004 ${\sim}$ September 2005. We also compared the biological data with long-term water quality data, obtained from the Ministry of Environment, Korea and physical habitat conditions based on the Quantitative Habitat Evaluation Index (QHEI). We used ten metric systems for the IBI model to evaluate biological stream health. Overall IBI values in Kap Stream averaged 24 (range: 20${\sim}$30, n=5), indicating a "fair ${\sim}$ poor" conditions according to the modified criteria of Karr (1981) and US EPA(1993). Exclusive of 4th survey, average IBI values at the upstream reach (S1 ${\sim}$ S3)and downstream reach (S4 ${\sim}$ S5) were 20 and 24, respectively. However, in 4th survey the averages were 21 and 20 in the upstream and downstream reaches, respectively. This difference was larger in the upstream than in the downstream because of physical condition disturbed during summer monsoon. Values of the QHEI varied from 75(fair condition) to 148 (good condition) and values of QHEI in the S3 were significantly (P=0.001, n=5) lower than other sites. Biochemical oxygen demand (BOD), chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) were greater by 3 ${\sim}$ 8 fold in the downstream than in the upstream reach. We believe that present IBI approach applied in this study may be used as a key tool to set up specific goals for restoration of Kap Stream.

Biological Stream Health and Physico-chemical Characteristics in the Keum-Ho River Watershed (금호강 수계에서 생물학적 하천 건강도 및 이화학적 특성)

  • Kwon, Young-Soo;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.145-156
    • /
    • 2006
  • The objective of this study was to evaluate biological health conditions and physicochemical status using multi-metric models at five sites of the Keum-Ho River during August 2004 and June 2005. The research approach was based on a qualitative habitat evaluation index (QHEI), index of biological integrity (IBI) using fish assemblage, and long-term chemical data (1995 ${\sim}$ 2004), which was obtained from the Ministry of Environment, Korea. For the biological health assessments, regional model of the IBI in Korea (An,2003), was applied for this study. Mean IBI in the river was 30 and varied from 23 to 48 depending on the sampling sites. The river health was judged to be "fair condition", according to the stream health criteria of US EPA (1993) and Barbour et al. (1999). According to the analysis of the chemical water quality data of the river, BOD, COD, conductivity, TP, TN, and TSS largely varied epending on the sampling sites, seasons and years. Variabilities of some parameters including BOD, COD, TP, TN, and conductivity were greater in the downstream than in the upstream reach. This phenomenon was evident in the dilution by the rain during the monsoon. This indicates that precipitation is a very important factor of the chemical variations of water quality. Community analyses showed that species diversity index was highest (H=0.78) in the site 1, while community dominance index was highest in the site 3, where Opsariichthys uncirostris largely dominated. In contrast, the proportions of omnivore and tolerant species were greater in the downstream reach, than in the upstream reach. Overall, this study suggests that some sites in the downstream reach may need to restore the aquatic ecosystem for better biological health.

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

NEAR-INFRARED VARIABILITY OF OPTICALLY BRIGHT TYPE 1 AGN (가시광에서 밝은 1형 활동은하핵의 근적외선 변광)

  • JEON, WOOYEOL;SHIM, HYUNJIN;KIM, MINJIN
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.47-63
    • /
    • 2021
  • Variability is one of the major characteristics of Active Galactic Nuclei (AGN), and it is used for understanding the energy generation mechanism in the center of AGN and/or related physical phenomena. It it known that there exists a time lag between AGN light curves simultaneously observed at different wavelengths, which can be used as a tool to estimate the size of the area that produce the radiation. In this paper, We present long term near-infrared variability of optically bright type 1 AGN using the Wide-field Infrared Survey Explorer data. From the Milliquas catalogue v6.4, 73 type 1 QSOs/AGN and 140 quasar candidates are selected that are brighter than 18 mag in optical and located within 5 degree around the ecliptic poles. Light curves in the W1 band (3.4 ㎛) and W2 band (4.6 ㎛) during the period of 2010-2019 were constructed for these objects by extracting multi-epoch photometry data from WISE and NEOWISE all sky survey database. Variability was analyzed based on the excess variance and the probability Pvar. Applying both criteria, the numbers of variable objects are 19 (i.e., 26%) for confirmed AGN and 12 (i.e., 9%) for AGN candidates. The characteristic time scale of the variability (τ) and the variability amplitude (σ) were derived by fitting the DRW model to W1 and W2 light curves. No significant correlation is found between the W1/W2 magnitude and the derived variability parameters. Based on the subsample that are identified in the X-ray source catalog, there exists little correlation between the X-ray luminosity and the variability parameters. We also found four AGN with changing W1-W2 color.

A Systematic Review of Community Elder Abuse Studies in South Korea (한국 지역사회 거주 노인학대 연구의 체계적 고찰)

  • Kim, Dong Ha;Kang, Serin;Lee, Yoon Kyoung;Cha, Ye Won;Yoo, Seunghyun;Kim, Hongsoo
    • 한국노년학
    • /
    • v.36 no.4
    • /
    • pp.1003-1024
    • /
    • 2016
  • The human rights of older people have gotten more attention recently in South Korea, a country that is in transition to a super-aged society. This study aimed to systematically review studies on elder abuse and related factors among community-dwelling older adults in South Korea over twenty years (1994-2016). We searched major databases (Riss, DBpia, KISS, KMbase, and PubMed) and identified published studies relevant to the topic. Based on inclusion and exclusion criteria related to study quality, a total of 31 studies were selected for this review. We examined types, measurements, and risk factors of elder abuse as well as study designs in the selected studies, guided by Johannesen's theoretical framework on elder abuse. All of the reviewed studies on elder abuse in Korea were cross-sectional studies, most of which focused on older people living in urban areas, using a non-random sampling method. All of the studies focused on certain types of elder abuse only. Some adopted elder-abuse instruments that were not validated, and others used self-developed instruments without psychometric tests. As for the risk factors of elder abuse in South Korea, the physical and mental health of the victims and aggressors impacted the risk of elder abuse, but general sociodemographic factors such as age, sex, and education were less likely to be related to the risk. In addition, decreasing caregiver burden and building elder-friendly communities are important for the prevention of elder abuse. Needed are further empirical studies on elder abuse with a theoretical framework that gives consideration to the unique sociocultural contexts of Korea. It is also recommended to develop instruments to measure elder abuse reflecting the sociocultural contexts of Korea, and to examine the multi-dimensional risk factors of elder abuse.

Characteristics and outcomes of patients with septic shock who transferred to the emergency department in tertiary referral center: multicenter, retrospective, observational study (상급종합병원 및 종합병원 응급실로 전원된 패혈성 쇼크 환자의 특성과 예후: 다기관 후향적 관찰연구)

  • Kim, Min Gyun;Shin, Tae Gun;Jo, Ik Joon;Kim, Won Young;Ryoo, Seung Mok;Chung, Sung Phil;Beom, Jin Ho;Choi, Sung-Hyuk;Kim, Kyuseok;Jo, You Hwan;Kang, Gu Hyun;Suh, Gil Joon;Shin, Jonghwan;Lim, Tae Ho;Han, Kap Su;Hwang, Sung Yeon;Korean Shock Society (KoSS)
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.5
    • /
    • pp.465-473
    • /
    • 2018
  • Objective: We evaluated the clinical characteristics and prognoses of patients with septic shock who transferred to the emergency department (ED) in a tertiary referral center. Methods: This study was performed using a prospective, multi-center registry of septic shock, with the participation of 11 tertiary referral centers in the Korean Shock Society between October 2015 and February 2017. We classified the patients as a transferred group who transferred from other hospitals after meeting the inclusion criteria upon ED arrival and a non-transferred group who presented directly to the ED. Primary outcome was hospital mortality. We conducted multiple logistic regression analysis to assess variables related to in-hospital mortality. Results: A total of 2,098 patients were included, and we assigned 717 patients to the transferred group and 1,381 patients to the non-transferred group. The initial Sequential Organ Failure Assessment score was higher in the transferred group than the non-transferred group (6; interquartile range [IQR], 4-9 vs. 6; IQR, 4-8; P<0.001). Mechanical ventilator (29% vs. 21%, P<0.001) and renal replacement therapy (12% vs. 9%, P=0.034) within 24 hours after ED arrival were more frequently applied in the transferred group than the non-transferred group. Overall hospital mortality was 22% and there was no significant difference between transferred and non-transferred groups (23% vs. 22%, P=0.820). Multivariable analysis showed an odds ratio for in-hospital mortality of 1.00 (95% confidence interval, 0.78-1.28; P=0.999) for the transferred group compared with the non-transferred group. Conclusion: The transferred group showed higher severity and needed more organ support procedures than the non-transferred group. However, inter-hospital transfer did not affect in-hospital mortality.