• Title/Summary/Keyword: Multi-chamber

Search Result 309, Processing Time 0.027 seconds

Multi-aging Test for Estimating Long Time Performance of Polymer Insulators for Transmission line (송전용 폴리마 런자의 장기성능을 위한 복합열화시험)

  • 조한구;한세원;이운용;윤문수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.640-643
    • /
    • 1999
  • This paper presents the results of multi-stress chamber experiments done to examine the tracking and erosion performance of polymer insulator. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. Therefore, multi-stress testing is believed to a suitable test for evaluating the aging performance of polymer insulator designs. We have nvestigated IEC 61109 Annex C for estimating long time performance of polymer insulator.

  • PDF

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

On MIMO OTA Performance Characterization Method for Mobile Devices with Multiple Antennas (MIMO 무선 성능 성능평가 방법에 관한 연구)

  • Cho, Y.S.;Kim, Y.R.;No, S.P.;Shim, H.J.;Kim, I.K.
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.5
    • /
    • pp.84-90
    • /
    • 2012
  • Since the major cellular data service providers in U.S, Japan as well as in Korea started the LTE (Long Term Evolution) service, there has been more strong need for the methods that can accurately measure the MIMO (Multi Input-Multi Outout) OTA (Over The Air) performance of LTE handsets because the performance of the MIMO antenna determines the packet data rates in the downlink and therefore the higher system throughput of the network. In this regard, there has been a lot discussions in 3GPP on the candidate MIMO OTA test solutions. In this paper, a faire comparison has been done for the conventional method, the Envelop Correlation Coefficient (ECC) measurements, and the anechoic chamber based MIMO OTA test solution, one of the candidate system being discussed in 3GPP. The evaluations and the comparisons are conducted by numerically and experimentally.

A Mixing Head Integrated, Multi-Ignition Device for Liquid Methane Engine (액체메탄엔진용 믹싱헤드 일체형 다중점화장치)

  • Lim, Byoungjik;Lee, Junseong;Lee, Keejoo;Park, Jaesung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.3
    • /
    • pp.54-65
    • /
    • 2022
  • We are developing a compact ignition device that can provide a multi-ignition capability for an upper stage methane engine of a two staged small satellite launch vehicle. Firstly, the multi-ignition device is designed and built as an integral part of an additively manufactured mixing head. Secondly, the ignition device requires no separate high-pressure vessels to store ignition propellants as they are branched out from the main feed lines for the mixing head. We performed experiments at various levels, including igniter autonomous tests, thrust chamber ignition and combustion tests on the new compact ignition device which is integrated in the thrust chamber of one-tonf class liquid oxygen/liquid methane engine, and confirmed stable ignition performance.

Confirmation of the Dose Distribution by Stereotactic Radiosurgery Technique with a Multi-purpose Phantom (다용도 팬톰에서 정위방사선수술기법의 선량 정확도 확인)

  • Yoo Hyung Jun;Kim Il Han;Ha Sung Whan;Park Charn Il;Hur Sun Nyung;Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.179-185
    • /
    • 2002
  • Purpose : For the purpose of quality assurance of self-developed stereotactic radiosurgery system, a multi-purpose phantom was fabricated, and accuracy of radiation dose distribution during radiosurgery was measured using this phantom. Materials and Methods : A farmer chamber, a 0.125 cc ion chamber and a diode detector were used for the dosimetry. Six MV x-ray from a linear accelerator (CL2100C, Varian) with stereotactic radiosurgery technique (Green Knife) was used, and multi-purpose phantom was attached to a stereotactic frame (Fisher type). Dosimetry was done by combinations of locations of the detectors in the phantom, fixed or arc beams, gantry angles $(20^{\circ}\~100^{\circ})$, and size of the circular tertiary collimators (inner diameters of $10\~40\;mm$). Results : The measurement error was less than $0.5\%$ by Farmer chamber, $0.5\%$ for 0.125 cc ion chamber, and less than $2\%$ for diode detector for the fixed beam, single arc beam, and 5-arc beam setup. Conclusion : We confirmed the accuracy of dose distribution with the radiosurgery system developed in our institute and the data from this study would be able to be effectively used for the improvement of quality assurance of stereotactic radiosurgery or fractionated stereotactic radiotherapy system.

Continuous Decomposition of Ammonia by a Multi Cell-Stacked Electrolyzer with a Self-pH Adjustment Function (자체 pH 조정 기능을 갖는 다단 전해조에 의한 암모니아의 연속식 분해)

  • Kim, Kwang-Wook;Kim, Young-Jun;Kim, In-Tae;Park, Geun-Il;Lee, Eil-Hee
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • This work has studied the changes of pH in both of anodic and cathodic chambers of a divided cell due to the electrolytic split of water during the ammonia decomposition to nitrogen, and has studied the continuous decomposition characteristics of ammonia in a multi-cell stacked electrolyzer. The electrolytic decomposition of ammonia was much affected by the change of pH of ammonia solution which was caused by the water split reactions. The water split reaction occurred at pH of less than 8 in the anodic chamber with producing proton ions, and occurred at pH of more than 11 in the cathodic chamber with producing hydroxyl ions. The pH of the anodic chamber using an anion exchange membrane was sustained to be higher than that using a cation exchange membrane, which resulted in the higher decomposition of ammonia in the anodic chamber. By using the electrolytic characteristics of the divided cell, a continuous electrolyzer with a self-pH adjustment function was newly devised, where a portion of the ammonia solution from a pHadjustment tank was circulated through the cathodic chambers of the electrolyzer. It enhanced the pH of the ammonia solution fed from the pH-adjustment tank into the anodic chambers of the electrolyzer, which caused a higher decomposition yield of ammonia. And then, based on the electrolyzer, a salt-free ammonia decomposition process was suggested. In that process, ammonia solution could be continuously decomposed into the environmentally-harmless nitrogen gas up to 83%, when chloride ion was added into the ammonia solution.

Multi-aging Test Technology for Estimating Long Time Performance of Polymer Insulators (폴리머 절연물 장기성능 평가를 위한 복합열화 시험기술)

  • Cho, H.G.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2332-2334
    • /
    • 1999
  • This paper presents the results of multi-stress chamber experiments done to examine the tracking and erosion performance of polymer insulator. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs including the nature of interfaces in insulation design. Therefore, multi-stress testing is believed to a suitable test for evaluating the aging performance of polymer insulator designs. We have investigated IEC 61109 Annex C for estimating long time performance of polymer insulator.

  • PDF

Merge Characteristic of PMMA Multi-port Hybrid Rocket (PMMA 연료를 적용한 Multi-Port 하이브리드 로켓의 포트 병합특성에 관한 연구)

  • Park, Su-Hyang;Kim, Gi-Hun;Lee, Jung-Pyo;Cho, Jung-Tae;Kim, Soo-Jong;Kim, Hak-Chul;Woo, Kyong-Jin;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.247-250
    • /
    • 2008
  • An experimental investigation was conducted to clarify the combustion characteristics and merge characteristics of PMMA-GOX and PE-GOX hybrid motor using multi-port fuel grain configuration. The regression rate of multi-port fuel grain is higher than the regression rate of single-port fuel grain by thermal conduction and chamber pressure. The merge of multi-port has an effect on hybrid rocket performance by change of a combustion area.

  • PDF

A Low-profile Internal Antenna for GSM/GPS/DCS/US-PCS Mobile Handsets (GSM/GPS/DCS/US-PCS 대역 이동 단말기용 저자세 내장형 안테나)

  • Jung Woo-Jae;Jung Byung-Woon;Lee Hak-Yong;Lee Byungie
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.1 s.6
    • /
    • pp.89-95
    • /
    • 2005
  • In this paper, a quad-band antenna for GSM/GPS/DCS/US-PCS handsets is proposed. The proposed antenna is low-profile for mounting in limited inner space of a handset. It consists of three open points with quarter wave length for multi-band operation. The ground plane below the patch is removed for wide-bandwidth without the variation of antenna size and the slot is added at the center of the patch for convenient matching in high frequency band. It provides a enough bandwidth within VSWR 3:1 at all bands. In addition, the measured peak gains are between -2.19 and 2.09 in anechoic chamber (10m$\times$6m$\times$4m).

  • PDF

Estimation of the History of "The Old House at No'eun-ri" and its Original Structure (홍성 "노은리 고택"의 건축 시기와 가구(架構)의 원형 고찰)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.1
    • /
    • pp.33-46
    • /
    • 2016
  • The old house at No'eun-ri, located in Hongseong-gun Hongbuk-myeon of the Chungcheong Nam-do province, really seems like the old house of late Seong Sam-mun who died in 1456. The original structure of the house seems to have been symmetrical, in terms of its left and right sides, and the females' chamber(Anchae) as well as the guest quarters(Haeng'rang-chae) would have featured a Matbae(맞배) fashion. The flank chamber and corridor would have displayed a multi-storied shape, and people would have been able to traverse the inside of the house all the way to the second story of the residence. We can see such shapes and dispositions from other 'ㅁ'-shaped houses - found in Chungnam and Gyeongbuk regions - which are now considered as distinct characteristics of certain residences constructed before the war with the Japanese in the 1590s, confirmed from extant vestiges and historical records of that time period. It can be concluded that the old house at No'eun-ri does harbor the traits and elements that resembled the upper class residences of the Joseon dynasty's early half period.