• 제목/요약/키워드: Multi-Stage

검색결과 2,077건 처리시간 0.027초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

한국판(韓國版) 식사태도(食事態度) 검사(檢査)-26에서 고득점(高得點)을 보인 한국(韓國) 일반(一般) 남성군(男性群)의 식사특성(食事特性)과 일반정신병리(一般精神病理) (Eating Traits and General Psychopathology of Korean Males Who Show High Score on the Korean Version of Eating Attitudes Test-26)

  • 한기석;이영호;이민규;박세현;손창호;정영조;홍성국;이병관;장필립;윤애리
    • 정신신체의학
    • /
    • 제7권1호
    • /
    • pp.87-102
    • /
    • 1999
  • 연구목적 : 본 연구의 목적은 한국 일반인구에서 식사 장애에 대한 고위험 남성 군(high risk male group for the eating disorders)의 유병율을 알아보고 이들의 인구학적 특징, 식사 행동과 연관된 특정 및 일반 정신 병리에 있어 특징을 알아 보는데 있다. 대상 및 방법 : 한국 일반 인구를 대상으로 한국판 식사 태도 경사(the Korean version of Eating Attitude Test-26 : KEAT-26)상 절단점 이상의 고득점을 보인 남성 군 52명을 최종 대상으로 여성 고득점군 208명과 비교하여 다음과 같은 결과를 얻었다. 결과 : 1) KEAT-26상 절단점 21 점 이상을 보였던 대상은 총 260/3062(8.5%)로 이중 남성이 52/260(20.0%), 여성이 208/260(80.0%) 이었으며(남성 대 여성의 비율 1 : 4) 전체 연구에 대한 비율은 남성이 52/3062(1.7%), 여성이 208/3062(6.8%) 이었다. 2) 인구학적 특정으로 평균 연령은 유의한 수준은 아니었으나 남성 군이 $29.13\pm7.87$세로 여성 군의 $27.00\pm6.81$세 보다 높은 경향을 보였다(p=0.0514). 평균 신체 질량 지수(Body Mass Index : BMI)는 남성 군이 $23.05\pm3.12$로 여성 군의 $20.40\pm2.31$보다 유의하게 높았고(p<0.01), 분포 또한 신체 질량 지수가 20이하인 경우도 남성 군은 7/52명 03.5%) 인데 반해 여성 군은103/208명(49.5%)으로 유의한 차이를 보였다(p<0.01). 신체 질병의 과거력은 두 군간에 유의한 차이를 보이지 않았으나 흡연율(p<0.01), 알코올 사용율(p<0.01) 및 한달 평균 알코올 사용량(p<0.01) 등은 모두 남성 군에서 여성 군보다 유의하게 높았다. 3) 사회 경제적인 특징 중 직업을 제외하고는 경제 상태, 교육 기간, 가족 수, 결혼 상태, 종교 및 대도시, 중간 크기의 도시, 소도시 및 시골지역 등으로 나누어 본 거주지역 등이 모두 두 군간에 유의한 차이를 보이지 않았다. 4) 식사 특성으로 식습관 척도 점수는 남성 군이 $7.25\pm3.15$로 여성 군의 $8.88\pm3.91$보다 유의하게 낮았으며(p<0.01), KEAT-26상 총 접수는 남성 군이 $25.80\pm4.87$ 여성 군이 $26.39\pm5.78$로 두 군 사이에 유의한 차이를 보이지 않았으나, 이 검사의 하위 척도인 마름에 대한 욕망(desire for thinness) 척도에서는 여성 군이 남성 군보다 유의하게 높았고(p<0.01), 음식에 대한 집착 척도(food preoccupation) 남성 군에서 여성 군보다 유의하게 높은 결과를 보여(p<0.05) 두 군 모두 식사 태도 검사 상 높은 점수를 보이고 있어도 질적인 내용에는 성에 따라 차이가 있음을 보여 주었다. 이외에 체중에 대한 통제 소재는 두군 사이에 유의한 차이를 보이지 않았으나 음식 선호도에 있어 남성 군이 여성 군에 비해 야채 및 생선을 더 싫어하고 단음식을 더 좋아하는 특정을 보여 주었다(p<0.01). 5) Eysenck성격 척도 상 남성 군이 정신병적 경향성에서 여성 군보다 유의하게 높은 접수를 보였다(p<0.01). 이외에 다른 성격 차원 및 Beck우울 척도 및 건강 염려증 척도로 측정한 일반 정신 병리 상의 특정은 두 군간에 유의한 차이를 보이지 않았다. 결론 : 상기 결과들은 우리 나라에서도 선진 외국과 비슷한 수준의 남성 식사 장애 환자들이 있을 가능성을 보여 주고 있다. 또한 상기 결과들은 식사 태도 검사 상 같은 고득점을 보여도 식사 관련 병리는 성에 따라 차이를 보일 수 있음을 보여 주고 있고, 남성 식사 장애 환자는 여성 식사 장애 환자보다 좀더 깊은 성격 병리를 가지고 있을 가능성을 보여 준다.

  • PDF

일부 농촌과 도시의 건강선별조사 자료로 본 백혈구수와 고혈압과의 관계 (Leukocyte count and hypertension in the health screening data of some rural and urban residents)

  • 이충원;윤능기;이성관
    • Journal of Preventive Medicine and Public Health
    • /
    • 제24권3호
    • /
    • pp.363-372
    • /
    • 1991
  • 백혈구수와 고혈압과의 관계를 알아보기 위해 1985년에 일부 농촌 거주자와 1986년에 일부 도시 거주자를 대상으로 혈액학적인 검사와 장기별로 기능검사를 통해서 건강선별조사를 했던 자료를 이용했다. 농촌거주자는 1985년에 경상북도 경산군에서 남자 206명, 여자 203명을 마을, 통, 반을 기준으로 다단계 집락추출법으로 추출했다. 도시 거주 대상자는 1985년 12월에 대구시에 거주하고 있는 20세 이상의 주민의 성별, 연령별 구성비율에 부합되게 농촌과 같은 표본추출방법으로 600명을 선정했으나 600명중 384명만이 본 조사에 응해주어서 나머지 인원은 피보험대상자들의 정기 신체검사를 위해 대학병원 건강관리과에 내원한 사람들 중에서 성, 연령을 짝지어서 추출했다. 이들 자료에서 백혈구수 측정이 빠진 사람, 고혈압력을 포함한 질병 유소견자와 검사상 극도의 비정상적인 수치를 보이는 자들을 농촌 거주자에서 36명 (8.8%), 도시 거주자에서 29명 (4.8%)을 제외시켜서 최종분석에 이용된 자는 도시가 571명, 농촌이 373명이었다. 백혈구수 측정은 ELT-8 Laser shadow method 를 이용했으며 단위는 $cells/mm^3$ 였다. 혈압 측정은 Aneroid 혈압계를 사용해서 표준화한 후 측정했다. 고혈압자의 정의는 수축기혈압 140 mmHg/확장기혈압이 90 mmHg 이상인 자로 했다. 농촌과 도시를 합한 총대상자에대해 고혈압자와 정상 혈압자간의 백혈구수의 평균을 비교하면 정상 혈압자에서 $6490.61{\pm}1941.32$, 고혈압에서 $6965.93{\pm}1997.01$로서 고혈압자에서 백혈구수의 평균이 통계적으로 유의하게 더 높았으며 (P=0.00), 농촌에서 동일한 방향의 유의한 차이를 보였다 (P=0.03). 그 외의 거주지와 성별로 층화한 각 층에서는 유의한 평균차이를 보이는 결과는 없었다. 총대상자에서 백혈구수 1/5분위수를 기준으로 했을 때 2/5분위수의 비차비가 0.99 (95% confidence interval, CI 0.62-1.59), 3/5분위수가 1.41 (95% CI 0.90-2.21), 4/5분위수가 1.76(95% CI 1.14-2.72), 5/5분위수가 1.80 (95% CI 1.15-2.82)로서 백혈구수가 증가 함에따라 고혈압의 유병율이 일정하게 상승하는 것을 알 수 있었으며 경향분석에서도 유의한 경향($X^2_{trend}=5.53,\;df=1,\;P<0.05$)을 나타내었다. 나머지 층에서는 유의한 비차비도 없었으며 유의한 경향 역시 보이지 않았다. 그러나 거주지와 성별로 층화한 각 층에서 연령, 흡연과 음주량을 다중지수회귀분석으로 통제를 했을 때 단일분석시 통계적인 유의성을 보였던 전체 대상자의 비차비는 통계적으로 유의하지 않게 되었고 그 크기 역시 작아지고 불안정해졌다. 전체적으로 비차비의 크기가 조금씩 줄었으며 경향분석에서도 유의한 경향을 보인 층은 없었다. 이러한 사실은 백혈구수와 고혈압과의 가설을 처음으로 제시했던 Friedman등의 연구가 고혈압의 예측변수를 찾기위해 800여개의 변수와 고혈압발생과의 관계를 보는 과정에서 우연히 발견된 통계적인 1종오차의 결과 일지도 모른다는 것을 시사해주는 결과이다.

  • PDF

보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획 (Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters)

  • 추성실;이상욱;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.53-65
    • /
    • 2001
  • 목적 : 비인강암 환자의 국소제어율을 향상시키기 위한 목적으로 보상 여과판을 이용한 전방위 강도변조 방사선치료방법(intensity modulated radiation therapy : IMRT)을 계획하고 기존 3차원 입체조형치료방법과 비교하여 최적의 방사선치료방법을 모색하고자 한다. 대상 및 방법 : 3-차원 입체조형치료계획으로 치료받았던 비강암환자(T4N0M0) 1예를 선택하여 치료면의 굴곡과 뼈, 공동 등 불균질 조직으로 인하여 발생되는 표적체적의 선량분포를 균일하게 만들고 주변 정상장기의 손상을 최소화하기 위한 일차 입사선량의 강도 조절을 보상여과판으로 시행 하였다. 환자는 열변성 plastic mask로 고정시킨 후 치료조준용 CT Scan (PQ5000)을 이용하여 3 mm 간격으로 scan 하고 가상조준장치(virtual simulator)와 3차원 방사선치료계획 컴퓨터$(ADAC-Pinnacle^3)$를 이용하여 보상여과판을 제작하였다. 각 조사면을 세분한 소조사선(beamlet)의 강도 가중치(weighting)를 계산하고 가중치에 따른 선량 감약을 보상여과판의 두께로 환산하여 판별이 쉽도록 도표화하였다. 방사선 치료성과의 기준은 정량적으로 평가할 수 있는 선량체적표(dose volume histogram : DVH)와 종양억제확율(tumor control probability : TCP)및 정상조직 손상확율(normal tissue complication probability : NTCP)의 수학적 관계식을 이용하여 치료효과를 평가하였다. 결과 : 전방위 IMRT에서 계획용표적체적(planning target volume: PTV)내의 최소선량과 최대선량의 차이가 입체조형치료계획보다 약간 증가하였으며 평균선량은 강도조절치료계획에서 약 $10\%$, 더 높았고 전체 방사선량의 $95\%$가 포함되는 체적(V95)은 비교적 양쪽 설계방법에서 비슷한 양상을 보이고 있었다. 주위 건강장기들의 DVH에서 방사선에 민감한 장기인 시신경, 측두엽, 이하선, 뇌간, 척수, 측두하악골관절 등은 강도조절치료계획에서 많이 보호되었다. PTV의 종양제어확율은 입체조형치료계획과 강도변조치료계획에서 모두 비교적 균일하였으며 계획선량이 50 Gy에서 80 Gy로 증가함에 따라 TCP가 0.45에서 0.56으로 완만하게 증가하였다. 척수, 측두하악골 관절, 뇌간, 측두엽, 이하선, 시신경교차, 시신경 등 정상장기의 손상확율은 입체조형치료계획보다 강도조절치료계획에서 월등히 감소되었으며 특히 뇌간(brain stem)의 NTCP는 입체조형치료계획에서 보다 강도조절치료계획에서 훨씬 적은 값(0.3에서 0.15)으로 감소되었다. 계획선량의 증가에 따른 TCP와 NTCP를 입체조형치료계획과 강도조절치료계획에서 TCP는 공히 완만한 증가를 보였으나 NTCP값은 선량증가에 비례적으로 증가하였고 입체조형치료계획이 강도조절치료계획보다 월등히 증가하였다. 결론 : 보상여과판을 이용한 전방위 강도변조 방사선치료에서 PTV내의 선량 균일도의 개선은 없었지만 뇌간, 척수강 등 정상장기의 피폭을 줄일 수 있었다. 특히 인체표면의 굴곡이 심하거나 뼈, 동공 등으로 종양에 도달하는 방사선량분포가 균일하지 않을 경우 매우 유리한 치료방법이였다. 방사선치료성적을 평가함에 있어 DVH와 TCP, NTCP 등 수학적 척도를 이용함으로서 치료성과의 예측, 종양선량의 증가(dose escalation), 방사선수술의 지표 및 방사선치료의 질적 상황을 정량적 수치로 평가할 수 있어 방사선치료성과 향상에 기여할 수 있다고 생각한다.

  • PDF

여성의 골관절염과 골밀도간의 관련성 분석 -구리시민 건강.영양진단 조사결과를 바탕으로- (Association of osteoarthritis and bone mineral density in women -The health and nutritional examination survey in Kuri-)

  • 신승수;이순영;민병현;서일
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권4호
    • /
    • pp.669-685
    • /
    • 1997
  • 백인여성들을 대상으로 골관절염과 골다공증 발생사이에 역상관 현상이 존재함을 관찰하고 보고한 기존의 연구결과를 통해 두 질환간 관련성이 존재하지 않나 추측해 볼 수 있다. 본 연구에서는 우리나라에서도 이런 관련성이 존재하는지를 파악하기 위해, "골관절염에 이환된 여성의 골밀도가 이환되지 않은 여성의 골밀도에 비해 유의하게 높을 것"이란 가설을 세우고 구리시민을 대상으로 실시된 건강 영양진단 조사 자료를 분석함으로써 이를 검증하고자 하였다. 대상 표본인구는 미리 설정된 조사구를 이용한 다단계 표본추출법을 이용하여 선정하였다. 1997년 8윌 18일부터 9월 10일까지의 조사기간 동안, 총 1,656명의 대상자가 선정되었으며 이중 867명이 조사에 응하여 수진율은 52.4%였다. 이 중 여성의 수는 519명이었다. 519명의 여성중 골밀도 측정, 방사선촬영, 신체계측을 모두 시행받은 420명을 대상으로 분석을 진행하였다. 그 결과는 다음과 같다. 1. 대상자의 일반적 특성 분석 결과: 평균 골밀도는 $0.493g/cm^2$, 평균 연령은 43.0세, 평균 신체비만지수는 $23.9kg/m^2$였다. 폐경을 맞이한 사람의 수는 106명, 자궁적출술을 시행받은 사람의 수는 19명이었다. 골관절염을 진단할 수 있었던 경우는 고관절염 0례, 슬관절염 64례, 손관절염 2례가 있었다. 2. 단변량 분석 결과: 슬관절염 이환 여부에 따른 평균 골밀도 비교 결과, 비이환군에 비해 이환군의 평균골밀도가 유의하게 낮았다(0.4269 대 $0.5057g/cm^2$). 그러나, 고관절염 및 손관절염 이환자는 수가 적어 이환여부에 따른 골밀도 비교분석을 실시하지 못했다. 폐경 여부에 따른 평균 골밀도 비교 결과, 폐경전군과 폐경군, 자궁적출군 사이에 평균 골밀도의 유의한 차이가 있었다(0.5204대 0.4206대 $0.4881g/cm^2$). 또한, 당뇨 이환 여부에 따른 평균 골밀도 비교 결과, 당뇨군과 내당력부전군, 정상군 사이에 평균 골밀도의 유의한 차이가 있었다(0.4297대 0.4874대 $0.5057g/cm^2$). 이외에 연령, 총임신회수, 신체비만지수, 체지방이 골밀도에 대해 유의한 음의 상관관계가 있었다. 3. 다변량 분석 결과: 다른 변수의 영향을 통제한 상태에서 골관절염과 골밀도간의 관련성을 밝히기 위해 단변량 분석에서 골밀도와 유의한 관련성이 있었던 변수들을 포함한 다중회귀분석 방정식을 만들어 검정하였다. 그 결과, 슬관절염 이환 여부는 골밀도에 대해 유의한 관련성을 보이지 않았다. 그러나, 연령과 폐경은 골밀도에 대해 유의한 음의 관련성이 있었다. 당뇨, 총임신회수, 신체비만지수, 체지방은 골밀도에 대해 유의한 관련성이 없었다. 대상자를 폐경 여부에 따라 층화하여 다중회귀분석을 시행한 결과, 폐경군에서는 연령이, 자궁적출군에서는 연령 및 슬관절염 이환이 골밀도에 대해 유의한 음의 관련성이 있었다. 이상의 연구 결과는 백인을 대상으로 시행한 기존의 다수 연구 결과들을 지지하는 내용이 아니다. 우리나라 여성에서 왜 이런 결과가 발생하였는지를 설명할 수 있는 생물학적 개연성에 대한 연구가 필요하다. 또한, 앞으로 단면조사연구가 아닌 시계열적인 연구를 통해 본 연구 결과를 다시 검증하는 것이 바람직할 것이다.

  • PDF

다혈관 관상동맥질환에서의 심폐바이패스를 사용하지 않은 관상동맥우회술과 약물용출 스텐트시술 (Off-pump Coronary Artery Bypass Surgery Versus Drug Eluting Stent for Multi-vessel Coronary Artery Disease)

  • 이재항;김기봉;조광리;박진식;강현재;구본권;김효수;손대원;오병희;박영배
    • Journal of Chest Surgery
    • /
    • 제41권2호
    • /
    • pp.202-209
    • /
    • 2008
  • 배경: 약물용출 스텐트의 출현으로 관상동맥우회술은 급격하게 위축되고 있으며, 이러한 현상은 관상동맥우회술이 일차적 치료법인 다혈관 관상동맥질환에도 적용되고 있다. 본 연구에서는 약물용출 스텐트의 출현이 관상동맥우회술에 미치는 영향을 분석하고(1단계), 다혈관 관상동맥질환 환자에서 관상동맥우회술과 약물용출 스텐트시술 후 1년 추적 임상 결과를 비교하였다(2단계). 대상 및 방법: 약물용출 스텐트의 출현이 관상동맥우회술에 미치는 영향을 알아보기 위해 본 병원에 약물용출 스텐트가 도입되기 전인 2001년 3월부터 2003년 2월까지 2년간 심폐바이패스를 사용하지 않고 관상동맥 우회술을 시행한 환자(n=298)와, 약물용출 스텐트의 사용이 활발해진 2003년 7월부터 2005년 6월까지 2년간 심폐바이패스를 사용하지 않고 관상동맥우회술을 시행한 환자(n=298)를 비교하였다(1단계). 관상동맥우회술과 약물용출 스텐트시술의 단기 임상 성적을 비교하기 위해, 2003년 3월부터 2004년 6월 사이에 약물용출 스텐트를 시행받은 환자(n=220)와, 약물용출 스텐트 도업 전후 2002년 3월부터 2004년 3월 사이에 관상동맥우회술을 시행받은 환자(n=255)를 대상으로 각각 1년 추적 관찰 후, 심근 경색의 발생, 심장 관련 사망의 빈도, 표적혈관 재관류율 등에 대하여 비교하였다(2단계). 결과: 약물용출 스텐트의 도입 이후, 경피적 관상동맥중재술 대비 관상동맥우회술의 비율이 감소하였으며, 관상동맥우회술군에서 대상 환자들의 고령화(62세 vs. 64세, p=0.023), 만성신부전 (4% vs 9%, p=0.021), 상행대동맥의 석회화 (9% vs. 15%, p=0.043) 등을 동반한 고위험군의 환자 빈도의 증가, 그리고 준응급 및 응급수술의 빈도(12% vs. 22%, p=0.002)가 증가 등이 관찰되었다. 하지만 이전과 비교하였을 때 수술 관련 사망 및 문합부위의 개존률에는 변화가 없었다(1단계). 1년 추적 기간 중 표적혈관 재관류율은 약물용출 스텐트시술 후가 관상동맥우회술보다 높았으며(12.3% vs. 2.4%, p<0.001), 이로 인하여 주요 심장사건(사망, 심근경색, 표적혈관 재관류율) 역시 약물용출 스텐트시술 후가 관상동맥우회술보다 증가하였다(13.6% vs. 4.3%, p<0.001). 하지만 표적혈관 재관류율을 제외 한 심장 관련 사망 및 섬근 경색의 빈도는 각각 1달과 1년 추적 결과 두 군간의 유의한 차이를 보이 지 않았다(2단계). 결론: 약물용출 스텐트의 출현 이후 관상동맥우회술을 시행받는 환자들의 동반질환 빈도가 증가하였다. 단기 추적 관찰 결과, 약물용출 스텐트의 시술 후 표적혈관 재관류율이 증가하였으며, 주요 심장사건의 발생이 증가하였으나, 심근 경색의 발생 및 사망률은 관상동맥우회술과 비슷한 조기 임상결과를 보였다.