• Title/Summary/Keyword: Multi-Span

Search Result 382, Processing Time 0.023 seconds

Load-Frequency Relationships of Continuous Compression Members (다 경간 압축재의 하중-진동수 관계)

  • 이수곤;김순철;임동혁
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.335-340
    • /
    • 1998
  • The apparently different physical problems of lateral vibration and elastic stability of a linear member are limiting cases of a single phenomenon, the more general expression being the mode of vibration with end thrust. For a single-span beam-column, it is generally known that the square of the frequency of lateral vibration is approximately linearly related to compressive axial force. In this paper the relationship between the frequency and axial force of multi-span compression members is investigated by means of the finite element method.

  • PDF

Parametric Fragility Analysis of Steel Highway Bridges (매개변수를 고려한 강도로교의 취약도분석)

  • Choi, Eunsoo;Choi, Il-Yoon
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.334-343
    • /
    • 2003
  • 본 논문의 목적은 스팅베어링의 기존교량과 납-고무베어링(Lead-Rubber Bearing)으로 내진 보강된 교량에 대해서 갭(Gap)의 크기가 교량의 지진 취약도에 미치는 영향에 대해서 평가하였다. 이를 위해서 다경간 단순교(Multi-Span Simply Supported Bridge)와 다경간 연속교(Muti-Span Continuous Bridge)를 대상으로 취약도 분석을 실시하였다 또한 다양한 크기의 갭사이즈를 도입하여 해석을 실시하였다. 이를 통해서 갭사이즈의 변화가 각 교량의 구성품에 미치는 영향을 확률적으로 평가할 수 있었고, 합성된 취약도 곡선을 이용하여 최적의 갭사이즈를 확정할 수 있었다.

  • PDF

Shear strength prediction of PRC coupling beams with low span-to-depth ratio

  • Tian, Jianbo;Shen, Dandan;Li, Shen;Jian, Zheng;Liu, Yunhe;Ren, Wengeng
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.757-769
    • /
    • 2019
  • The seismic performance of a coupled shear wall system is governed by the shear resistances of its coupling beams. The plate-reinforced composite (PRC) coupling beam is a newly developed form of coupling beam that exhibits high deformation and energy dissipation capacities. In this study, the shear capacity of plate-reinforced composite coupling beams was investigated. The shear strengths of PRC coupling beams with low span-to-depth ratios were calculated using a softened strut-and-tie model. In addition, a shear mechanical model and calculating method were established in combination with a multi-strip model. Furthermore, a simplified formula was proposed to calculate the shear strengths of PRC coupling beams with low span-to-depth ratios. An analytical model was proposed based on the force mechanism of the composite coupling beam and was proven to exhibit adequate accuracy when compared with the available test results. The comparative results indicated that the new shear model exhibited more reasonable assessment accuracy and higher reliability. This method included a definite mechanical model and reasonably reflected the failure mechanisms of PRC coupling beams with low span-to-depth ratios not exceeding 2.5.

Reduced Model of the PC Segmental Multispan Bridge Constructed by Free Cantilever Method for Investigation of Deflection and Member Force (캔틸레버공법 PC 세그멘탈 다경간 교량의 처짐 및 단면력 검토를 위한 축소모델에 관한 연구)

  • Lee, Jae Hoon;Lee, Myeong-Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.1-13
    • /
    • 1993
  • In design of prestressed concrete structures, structural analysis is performed normally several times for selection of adequate sectional dimension and tendon amount. Especially for precast segmental multi-span bridges. time consuming structural analysis process due to time dependent material properties and structural system change could be effectively reduced by use of a reduced-span bridge model. 5-span and 3-span bridges are selected as reduced-span models for the 10-span full bridge to investigate the acceptability in practical design. The analytical results of deflection, total moment, statical moment, and ultimate moment of the reduced span-models are compared with those of the 10-span full bridge. Application of the load factors to structural analysis for ultimate moment calculation in prestressed concrete is reviewed and a rational method is proposed.

  • PDF

Experimental Analysis on Yield Strength of Pipe Connectors and Joints for Pipe Framed Greenhouses (파이프골조 온실의 조립연결구 내력에 관한 실험적 연구)

  • Nam, Sang-Woon;Kim, Moon-Ki;Kwon, Hyuck-Jin
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.271-274
    • /
    • 2001
  • Experiments on the yield strength of pipe connectors made of metal wire, joint pins, pole pipes, multi span insertion joints, and T-clamp joints used in pipe houses were conducted. The strength of connections of a pipe connector made of metal wire was adequate but it had a big difference according to loading direction. The collapse load of pipes connected with a joint pin was lower than that of single pipes. Also experimental results showed that pole pipes for use in a part of frame buried under the ground were safe, and the strength of multi span insertion joints should be increased. The resistant moment of T-clamp was about 13.7% of a single pipe.

  • PDF

Mode identifiability of a multi-span cable-stayed bridge utilizing stabilization diagram and singular values

  • Goi, Y.;Kim, C.W.
    • Smart Structures and Systems
    • /
    • v.17 no.3
    • /
    • pp.391-411
    • /
    • 2016
  • This study investigates the mode identifiability of a multi-span cable-stayed bridge in terms of a benchmark study using stabilization diagrams of a system model identified using stochastic subspace identification (SSI). Cumulative contribution ratios (CCRs) estimated from singular values of system models under different wind conditions were also considered. Observations revealed that wind speed might influence the mode identifiability of a specific mode of a cable-stayed bridge. Moreover the cumulative contribution ratio showed that the time histories monitored during strong winds, such as those of a typhoon, can be modeled with less system order than under weak winds. The blind data Acc 1 and Acc 2 were categorized as data obtained under a typhoon. Blind data Acc 3 and Acc 4 were categorized as data obtained under wind conditions of critical wind speeds around 7.5 m/s. Finally, blind data Acc 5 and Acc 6 were categorized as data measured under weak wind conditions.

Seismic Performance Evaluation of Multi-Span Bridges considering Effect of Lateral Load Distributions and Equivalent SDOF methods (횡하중 분포와 등가단자유도 방법의 영향을 고려한 다경간 교량의 내진성능 평가)

  • Song, Jong-Keol;Nam, Wang-Hyun;Chung, Yeong-Hwa
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.163-171
    • /
    • 2006
  • To evaluate inelastic seismic responses of multi-span-bridge, the equivalent single-degree-of-freedom (ESDOF) methods and the lateral load distributions are applied to the capacity spectrum method(CSM). From the pushover analysis results using the four ESDOF methods and the six types lateral load distributions, the ESDOF method more than lateral load distribution is found to have an important influence upon the pushover analysis. The effects of the higher mode on the bridge seismic behaviors are also increased as the number of pier increase. Therefore, it can be concluded that lateral load distributions and ESDOF methods for reflection of higher mode effects should be considered in the seismic analysis of the bridge structural.

  • PDF

Longitudinal Tension Control at Start and Stop in a Multi-span Continuous Process System (변속시의 멀티 스팬 연속 공정 시스템의 장력제어)

  • 신기현;권순오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.584-589
    • /
    • 1994
  • A time-varying nonlinear mathematical model was derived to consider the effect of change in roll radius on tension varation during winding and unwinding. A variable-gain PID controller was designed for tension control at start and stop in a multi-span continuous process system. The controller gains are updated at every control loop as roll radii continuously change. Computer simulation was carried out by using the mathematical model and the controller developed for a typical operating condition including acceleration and deceleration. When the variable-gain PID controller was used, the tension control performance was improved compared with that of existing control method during start-up and stop.

  • PDF

A comparative study on aseismic performances of base isolation systems for multi-span continuous bridge (다경간 연속교에 대한 면진용 교좌장치의 내진성능 비교연구)

  • Park, Kyu-Sik;Lee, Chong-Heon;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.383-390
    • /
    • 2001
  • Various base isolation systems, which are widely used, are compared for aseismic performances of multi-span continuous bridge. They are the P-F, RB, LRB, R-FBI and EDF systems. Sensitivity analyses are carried out to determine the design parameters of various devices. The design parameters, natural period of the isolated bridge and friction coefficient of the bearing, are determined by the reciprocal relationship between displacement and bending moment of the structure. Then the relative effectiveness of the bearings is described. Bridge with the R-FBI system shows the smallest peak displacement of deck whereas bridge with the EDF system shows the smallest peak bending moment of the lower end of pier in numerical examples. Furthermore, the peak responses of bridge with the friction type bearing are less sensitive to substantial variations in the frequency range and intensity of the ground excitation than those with the rubber type bearing.

  • PDF

SEISMIC RESPONSE CHARACTERISTICS OF THE MULTI-SPAN CONTINUOUS GBRIDGE WITH SHEAR KEYS (전단키와 있는 다경간 연속교의 지진응답특성)

  • 이지훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.120-127
    • /
    • 1998
  • This paper deals with the dynamic responses of the multi-span continuous bridge with longitudinal shear keys. It is motivated by a need to understand the effects of longitudinal shear keys which may be used for the reduction of the longitudinal seismic force in continuous bridges. The results show that (1) The force reduction of fixed pier is proportional to the ratio of gap size and elastic maximum displacement of the bridges without shear keys ; (2) The thermal movement has little effect on the response of the continuous bridges with shear keys. Also the simplified equation is proposed to calculate the maximum response of the continuous bridges with longitudinal shear keys. The equation requires only the elastic analysis results of the bridge and the gap size between superstructure and shear keys.

  • PDF