• 제목/요약/키워드: Multi-Frequency Case

검색결과 232건 처리시간 0.028초

The Novel Method of Segmental Bio-Impedance Measurement Based on Multi-Frequency for a Prediction of risk Factors Life-Style Disease of Obesity (비만관련 생활습관병 위험인자 예측을 위한 다중 주파수 기반의 분할 체임피던스 측정법)

  • Kim, Eung-Seok;Noh, Yeon-Sik;Seo, Kwang-Seok;Park, Sung-Bin;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • 제31권5호
    • /
    • pp.375-384
    • /
    • 2010
  • The purpose of this study is to determine whether there is a correlation between the segmental bio-impedance measurement with the frequency modulations and the life-style disease of obesity. An obesity is not simply the factor for estimating the life-style disease of obesity, but also the risk factor occurring. There are many methods (BMI, WHR, Waist, CT, DEXA, BIA, etc.) for measuring a degree of obesity; the bio-impedance measurement is more economic and more effective than others. The physical examination, the blood test, the medical imaging diagnosis and the bio-impedancemeasurementswithmultiple frequencies for each body parts have been conducted for 77 people. The estimated value has been calculated through a segmental bio-impedance model based on multi-frequency that was created to reflect the highest correlation by analyzing correlation with linear regression analysis method for the measured bio-impedance and the risk factors. Then we compared with the clinical diagnosis. In case of high level cholesterol, low HDL-C and high LDL-C for life-style disease, the sensitivity is 80~100%and the specificity is 83~100%. This study has shown conclusively that bio-impedance can be a possible predictor to analyze the disease risk rate of population and individual health maintenance. And also the multi-frequency segmental bio-impedance can be used as early predictor to estimate the life-style disease of obesity.

The Prediction of Dynamic Fatigue Life of Multi-axial Loaded Structure (다축 하중 구조물의 동적 피로수명 예측)

  • Yoon, Moon Young;Kim, Kyeung Ho;Park, Jang Soo;Boo, Kwang Seok;Kim, Heung Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제30권2호
    • /
    • pp.231-235
    • /
    • 2013
  • The purpose of this paper is to compare with estimation of equivalent fatigue load in time domain and frequency domain and estimate the fatigue life of structure with multi-axial vibration loading. The fatigue analysis with two methods is implemented with various signals like random, sinusoidal signals. Also an equivalent fatigue life estimated by rainflow cycle counting in time domain is compared with results estimated with probability density function of each signal in frequency domain. In case of frequency domain, equivalent fatigue life can estimate through Dirlik's method with probability density function. And the work proposed in this paper compared the fatigue damage accumulated under uni-axial loading to that induced by multi-axial loading. The comparison is preformed for a simple cantilever beam, which is exposed to vibrations of several directions. For verification of estimation performance of fatigue life, results are compared to those of FEM analysis (ANSYS).

Optimal Switching Frequency in Limited-Cycle with Multiple Periods

  • Sun, Jing;Yamamoto, Hisashi;Matsui, Masayuki;Kong, Xianda
    • Industrial Engineering and Management Systems
    • /
    • 제11권1호
    • /
    • pp.48-53
    • /
    • 2012
  • Due to the customer needs of reducing cost and delivery date shorting, prompt change in the production plan became more important. In the multi period system (For instance, production line.) where target processing time exists, production, idle and delay risks occur repeatedly for multiple periods. In such situations, delay of one process may influence the delivery date of an entire process. In this paper, we discuss the minimum expected cost of the case mentioned above, where the risk depends on the previous situation and occurs repeatedly for multiple periods. This paper considers the optimal switching frequency to minimize the total expected cost of the production process. In this paper, first, the optimal switching frequency model is proposed. Next, the mathematic formulation of the total expectation is presented. Finally, the policy of optimal switching frequency is investigated by numerical experiments.

A Study on Fatigue Analysis of Non-Gaussian Wide Band Process using Frequency-domain Method (주파수 영역 해석 기법을 이용한 비정규 광대역 과정의 피로해석에 관한 연구)

  • Kim, Hyeon-Jin;Jang, Beom-Seon
    • Journal of the Society of Naval Architects of Korea
    • /
    • 제55권6호
    • /
    • pp.466-473
    • /
    • 2018
  • Most frequency domain-based approaches assume that structural response should be a Gaussian random process. But a lot of non-Gaussian processes caused by multi-excitation and non-linearity in structural responses or load itself are observed in many real engineering problems. In this study, the effect of non-Normality on fatigue damages are discussed through case study. The accuracy of four frequency domain methods for non-Gaussian processes are compared in the case study. Power-law and Hermite models which are derived for non-Gaussian narrow-banded process tend to estimate fatigue damages less accurate than time domain results in small kurtosis and in case of large kurtosis they give conservative results. Weibull model seems to give conservative results in all environmental conditions considered. Among the four methods, Benascuitti-Tovo model for non-Gaussian process gives the best results in case study. This study could serve as background material for understanding the effect of non-normality on fatigue damages.

Performance Analysis of Synchronous Downlink MC-CDMA with Precoding and Frequency Offset

  • Jang, Won-Mee;Lee, Moon-Woo
    • Journal of Communications and Networks
    • /
    • 제9권2호
    • /
    • pp.192-197
    • /
    • 2007
  • We analyze the performance of code division multiple access (CDMA) system with multicarrier (MC) that employs precoding in synchronous downlink channels. Even though considerable efforts are undergoing for frequency offset estimation and correction, it is inevitable for the system to bear the remaining frequency offset. Therefore it is important to predict accurately the system performance in the presence of the residual frequency offset. We obtain the bit error rate (BER) performance in terms of the number of users, the spreading factor, the number of sub-carriers, and frequency offset. We assume that the spreading factor is equal to the number of sub-carriers, although we can generalize the case. The simulation results show that the BER of MC-CDMA with precoding shows a performance that varies with frequency offset as well as system loading.

A Multi-Section Complex-Coupled DFB Laser with a Very Wide Range of Self-Pulsation Frequency and High Modulation Index (매우 넓은 영역의 Self-Pulsation 주파수와 높은 변조 지수를 가자는 다중 영역 복소 결합 DFB 레이저)

  • Kim, Boo-Gyoun;Kim, Tae-Young;Kim, Sang-Taek;Kim, Sun-Ho;Park, Kyung-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • 제17권2호
    • /
    • pp.191-197
    • /
    • 2006
  • We analyze the self-pulsation(SP) characteristics due to mode beating of two modes emitted in a multi-section complex-coupled (CC) DFB laser composed of two DFB sections and a phase control section between them. SP frequency due to mode beating of the two modes is determined by the difference of grating periods in the two CC DFB regions. As the difference of grating periods in the two CC DFB regions increases, the SP frequency increases from very low frequency to the THz region. In the case of a mode which is not located in the stop band of the other DFB region, the mode propagates into the other DFB region without a high reflection, so that output powers emitted in a multi-section CC DFB laser have high modulation indexes due to the large interaction between the two modes.

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

A Study on the Intenna Based on PIFA with Multi Element (Mulit Element를 이용한 PIFA 구조의 Intenna에 관한 연구)

  • Lim, Yo-Han;Chang, Ki-Hun;Yoon, Young-Joong;Kim, Yong-Jin;Kim, Young-Eil;Yoon, Ick-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제18권7호
    • /
    • pp.784-795
    • /
    • 2007
  • In this thesis, the Multi element antenna with wideband and enhanced gain characteristic is proposed to operate at both frequency range from 824 MHz to 896 11Hz for the CDMA and frequency range from 908.5 MHz to 914 MHz for the RFID band. The proposed antenna has tile size of $35{\times}15{\times}5mm^3$ in order to put it in the A model of S company and each element of the proposed antenna is folded to obtain the minimum size. To obtain the antenna with wideband and high gain characteristic, the radiator of the antenna is divided into 4 elements. As a result, bandwidth of the proposed antenna become broader and lower center frequency is appeared due to increased and lengthened current path. Moreover, the enhanced gain characteristic is verified because divided element structure that induct uniform current distribution can get increased antenna efficiency. To attain more uniform current distribution, modified structure of the feeding point that can deliver currents directly is designed. The antenna that alters the feeding structure has higher gain value. Each element is folded to increase the current paths considering the current directions to attain the miniaturization of the antenna. To measure the handset antenna, the handset case must be considered. Even though antenna is designed for predicted characteristic, the resonance frequency is shifted and antenna gain is deteriorated at predicted frequency while antenna is set in the handset case. 1.08 GHz of the resonant frequency is determined after frequency shift from 150 MHz to 200 MHz is confirmed and the maximum gain is measured as 3.1 dBi while antenna is not set in the handset. In case handset case is considered, the experimental results show that the impedance bandwidth for VSWR<2 is from 0.824 GHz to 0.936 GHz(110 MHz). This result appears that the proposed antenna can cover both CDMA and RFID band at once. The measured gain is from -3.4 dBi to -0.5 dBi and it has omni-directional pattern practically.

Active Vibration Control of Acoustically Loaded Flexible Plate Enclosure Using Multi-Channel Control Algorithm (다채널 제어알고리듬을 이용한 음향 가진된 밀폐계 평판의 능동진동제어)

  • Hong, Jin-Seok;Park, Su-Hong;Kim, Heung-Seop;O, Jae-Eung;Jeong, Jin-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제24권6호
    • /
    • pp.1390-1397
    • /
    • 2000
  • This paper presents the multi-channel active vibration control of a flexible plate of the acoustically loaded enclosure. The flexible plate was excited acoustically with sinusoidal and white noise input. The control was performed by two piezo ceramic actuators and two accelerometers. The experimental results were compared with the single channel control results. In the case of white noise input, 20 dB of vibration reduction was achieved below 300Hz frequency range. The experimental results demonstrate that multi-channel filtered-x LMS algorithm is effective than single-channel filtered-x LMS algorithm in active vibration control of plate.

An Improved Dynamic Model for Multi-Stepped Rotor System (다단 회전체 계의 동적 모델 개선에 관한 연구)

  • Hong Seong-Wook;Choi Seong-Hwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • 제15권2호
    • /
    • pp.107-113
    • /
    • 2006
  • This paper presents an efficient dynamic modeling method for multi-stepped rotor system using effective spring elements to take into account the structural weakening effect due to the steps. This paper demonstrates that the Timoshenko shaft model give rise to a significant error in the case of multi-stepped rotors. An effective bending spring model is introduced to represent the structural weakening effect in the presence of steps. The proposed modeling method is validated through a series of simulations and experiments. Finally, a spindle is dealt with as an analysis example.