• Title/Summary/Keyword: Multi-Conductors

Search Result 57, Processing Time 0.042 seconds

A Study of Voltage Distribution on Coils and Turns in Inverter Fed Induction Motor (인버터 구동 유도전동기의 코일과 턴에서의 전압 분포 연구)

  • Kwon, B.H.;Ahn, J.R.;Chun, T.W.;Kim, H.G.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.112-114
    • /
    • 2007
  • The voltage stress on line-end coil of the stator winding in the induction motor fed by a PWM inverter is analyzed, using the computer model based on multi-conductors transmission line. A method to calculate circuit parameters, especially, capacitance between the turns and ground is proposed. The voltage distributions inside coil at motor terminal depending on dv/dt are investigated through simulation studies.

  • PDF

Calculations of Load Current of Multi-Stage Cascaded Transmission Lines Excited by a Small Loop in the Near-Field Region (작은 루우프 안테나의 근거리장 영역내에 있는 다단 연쇄 접속 전송선로에 유기되는 부하 전류 계산)

  • 박영태;이상설
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.6
    • /
    • pp.836-842
    • /
    • 1990
  • The noise currents in the load of cascaded transmission lines excited by a nearly small loop are analyzed and the effective approxiamte method by which we can calculate these currents easily and the computation time can be significantly reduced is developed. Numerical results for n=3 are well agreed with those of Smith by the maximum difference of 3-4dB and show that the length of a segment of line regarded to be illuminated by uniform electric fields should be 1.3 times the distance from the loop to the point midway between the conductors.

  • PDF

Analysis of Current Distribution with Design Parameters of HTS Cable with Multi-Layer (다층 고온초전도 전력케이블의 설계 파라미터를 통한 전류분류 해석)

  • Lee, Jong-Hwa;Lim, Sung-Hun;Ko, Seok-Cheol;Park, Sig;Kang, Hyeong-Gon;Han, Byong-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.589-592
    • /
    • 2003
  • One important issue in the design and the optimization for conductor of a superconducting cable is the control of the current distribution flowing at each layers. In this paper, we calculated the self inductance of each layer and the mutual inductance between two layers from the magnetic field energy and investigated the effects of design parameters on the self and mutual inductances for 4-layer conductors with transport current distribution at each layer.

  • PDF

AC Loss Measurement and Analysis of Ag-sheathed Bi-2223 Conductors in Terms of Eddy Currents and Flux Creep

  • Jang, Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.211-215
    • /
    • 2003
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb] : Sr : Ca : Cu :O = 2:2:2:3) tapes [one untwisted (Tape I, twist-pitch of $\infty$ mm) and the other with a twist-pitch of 8mm (Tape II) ] were measured and compared. These samples, produced by the powder-in-tube (PIT) method, are multi-filamentary and have a Ag/Au and Ag matrix, respectively. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation.

A Study on Multi-conductor Bundle for EHV Transmission Line Considering Corona Noise Characteristics (코로나 잡음 특성을 고려한 초고압 송전선의 다중도체배열방식 연구)

  • 민석원;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.5
    • /
    • pp.508-515
    • /
    • 1990
  • This paper describes the corona characteristics of conductor bundle for EHV transmission line. To reduce the corona noise, the asymmetric conductor bundle to minimize the electric field of the conductor surface is proposed. The charge simulation method is used to formulate the electric field of conductor surface and the optimal arrangement of subconductor to minimize it is selected to apply the nonlinear successive quadratic programming. Through the analytical comparison and the corona cage test, it is proved that the asymmetric conductor bundle proposed in this paper can reduce the average maximum electric field of the phase conductors and the corona noise more than the conventional symmetric conductor bundle and asymmetric conductor bundle by GE.

  • PDF

Toughnening of Dielectric Material by Thermoplastic Polymer

  • Lee, Jung-Woo;Cho, Jae-Choon;Ra, Seung-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.207-208
    • /
    • 2007
  • Recently, high performance microelectronic devices are designed in multi-layer structure in order to make dense wiring of metal conductors in compact size. Imprint lithography have received significant attention due to an alternative technology for photolithography on such devices. In this work, we synthesized dielectric composite materials based on epoxy resin, and investigated their thermal stabilities and dynamic mechanical properties for thermal imprint lithography. In order to enhance the mechanical properties and toughness of dielectric material, various modified polyetherimide(PEI) was applied in the resin system. Curing behaviours, thermal stabilities, and dynamic mechanical properties of the dielectric materials cured with various conditions were studied using dynamic differential scanning calorimetry (DSC), thermo gravimetric analysis (TGA), and Universal Test Method (INSTRON).

  • PDF

A Study on AC Loss in the Two-parallel Solenoid Coil using Multi-stacked conductors (적층형 도체를 이용한 2병렬 솔레노이드 코일의 교류손실 연구)

  • Hwang, Young-Jin;Choi, Suk-Jin;Chang, Ki-Sung;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.820_821
    • /
    • 2009
  • 전력기기는 일반적으로 상용주파수인 60 Hz의 교류 전원하에서 운용된다. 따라서 고온초전도체를 전력기기에 응용하는데 있어 교류전류나 교류자장에 의한 교류손실 발생 문제는 전력기기의 경제적 운용과 관련하여 중요하게 부각되어 왔다. 또한 고온초전도체에서 발생하는 교류손실은 에너지의 열적 변환으로 인한 냉동부하 문제와도 관련되어 있기 때문에 전력기기의 안정적인 운용을 위해서도 반드시 연구되어야 할 부분이다. 특히 변압기와 같이 유도형 권선이 필요한 전력기기의 경우에는 무유도 권선 형태가 적용되는 다른 전력기기에 비해 교류 손실의 크기가 매우 크기 때문에 이를 줄이기 위한 방안에 대한 연구가 다각도로 이루어지고 있다. 본 연구에서는 임계전류와 인덕턴스의 크기는 동일하지만 권선 형태를 다르게 할 수 있는 유도형 솔레노이드 코일을 제작하였다. 그리고 제작된 솔레노이드 코일의 병렬연결 구조를 달리하여 각각의 구조에 대한 교류손실의 차이를 측정하고 분석하였다. 그리하여 측정된 결과를 토대로 고온초전도 선재를 이용한 솔레노이드 코일에서 교류손실을 줄이기 위한 구조적 방안을 제시하고자 한다.

  • PDF

Development Progress of a 300 kW-class HTS DC Induction Furnace (300 kW 급 대용량 초전도 직류 유도가열로 개발)

  • Choi, Jongho;Go, Byeong-Soo;Park, Hee-Chul;Park, Minwon;Yu, In-Keun;Kim, Seokho;Sim, Kideok;Jo, Sangho;Jo, Jinsik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1112-1113
    • /
    • 2015
  • In the end of 2014, Changwon National University and TECHSTEEL Co., Ltd. had initiated a project on the development of a 300 kW-class HTS DC Induction Furnace(HTS DC IF) for preheating non-ferrous metal billets funded by the Korea Institute of Energy Technology Evaluation and Planning for 3 years. This is the one of the most realistic commercial machines applying the coated conductors. In this paper, the development progress of a 300 kW-class HTS DC IF was introduced. The major characteristics of the furnace including its capacity, structure and operation scheme were presented. For ensuring the successful design, a pre-validation study was performed through the electromagnetic, heat transfer and solid mechanical analysis using a multi-physics FEM tool. The aluminum billet was heated up to $540^{\circ}C$ under 1 T of the magnetic flux density at the center of the billet, and the simulation results were described in detail.

  • PDF

Effect of Preparation Parameters of Sulfur Cathodes on Electrochemical Properties of Lithium Sulfur Battery

  • Zhao, Xiaohui;Kim, Dul-Sun;Ahn, Hyo-Jun;Kim, Ki-Won;Jin, Chang-Soo;Ahn, Jou-Hyeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.3
    • /
    • pp.169-174
    • /
    • 2010
  • Sulfur cathodes were prepared by ball milling method with different types of electronic conductors and binders in different ball milling time. The sulfur cell with a cathode prepared in 45 min ball milling time gave an initial discharge capacity of 794mAh/g with Super-P as an electronic conductor and poly(vinylidene fluoride) as a binder. The cathode with multi-walled carbon nanotube as an electronic conductor showed an initial discharge capacity of 944 mAh/g and a discharge capacity of 300 mAh/g after 20 cycles. Cathodes with poly(ethylene oxide) and poly(vinylidene fluoride) as binders showed different cycle performance.

Minimization of Crosstalk by Optimum Synthesis of Profiles of Multiple Coupled Data Transmission Lines on Microstrip (다중결합된 마이크로스트립 데이터 전송로 자태의 최적합성을 통한 누화 최소화)

  • 박의준
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.1-11
    • /
    • 1998
  • A line profile synthesis method is presented that minimizes the nearest-neighbor crosstalk peak level for high-speed pulse transmission in multi-coupled microstrip signal buses. We adopted the optimization technique for the reflected wave control on bus lines resulting in increasing the average spacing between strip conductors, since in a parallel-conductor bus the crosstalk energy is concentrated at the nearest neighbors of the driven line. The generalized S-matrix technique is applied for the input and output waveform prediction, and crosstalk characteristics of various nonuniform lines synthesized for increasing the average spacing are analyzed by comparing each other. Simulation results demonstrate that the Chebyshev taper with dips is adequate to significantly minimize the crosstalk peak level under the satisfactory waveform integrity since the profile is oriented to evenly reflect significant pulse spectra within the frequency range of pulse.

  • PDF