• 제목/요약/키워드: Multi-Coil

검색결과 186건 처리시간 0.026초

3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향 (Effect of Temperature on T1 and T2 Relaxation Time in 3.0T MRI)

  • 김호현;권순용;임우택;강충환;김경수;김순배;백문영
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.63-68
    • /
    • 2013
  • Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials' temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to $45^{\circ}C$. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were $214.39{\pm}0.25$, $236.02{\pm}0.87$, $267.47{\pm}0.48$, $299.44{\pm}0.64$, $330.19{\pm}1.72$ ms. T2 relaxation times were $180.17{\pm}0.27$, $197.17{\pm}0.44$, $217.92{\pm}0.39$, $239.89{\pm}0.53$, $257.40{\pm}1.77$ ms. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p< 0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature's differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

  • PDF

여러 개의 모터에 의하여 제어되는 링-코어 자동 선별기 개발 ((Development of Ring Core Auto-Classifier by Multi-Motor Control))

  • 박인규
    • 전자공학회논문지SC
    • /
    • 제39권2호
    • /
    • pp.104-115
    • /
    • 2002
  • 인덕터 전기 부품을 구성하는 핵심 부품인 링-코어를 물질 특성, 인덕턴스 값 및 Q-값에 따라 10등급으로 분류하는 선별기를 설계하는 데 있어, 한번에 10개의 코어를 동시에 자동 분류할 수 있도록 설계한다. 동시에 10개의 코어를 자동 선별하려면 10개의 측정 장비가 필요한데, 이러한 측정 장비는 대단히 고가이므로, 하나의 측정 장비를 사용하여 10개의 링-코어를 검사한 후, 각각의 등급에 따라서 해당 그릇으로 저장하도록 한다. 이러한 시스템을 개발하는 데 있어서, 초당 0.5개의 생산 속도보다 빠른 속도인 초당 1개 정도로 측정 분류할 수 있는 속도가 필요하다. 시스템의 구성물은 먼저 작업 명령을 내려주고, 각종 생산 및 품질 통계를 관리하는 작업 PC와, 100개의 고무호스, 공급기, 측정기, 10개의 등급-상자, 1개의 메인-보드, 10개의 모터-제어-보드, 10개의 모터-드라이버-보드, 10개의 스텝-모터 등으로 구성되어 있다. 따라서 많은 고장, 오동작이 예상된다. 가장 중요한 사항은 일부의 모터 고장, 일부 모터 드라이버 보드 고장, 일부 모터 제어 보드 등의 고장이 발생하여도 작동이 멈추지 않도록 설계하는 것이다. 이를 위하여 센서 회로 추가 및 관련 소프트웨어 알고리즘을 개발한다.

펄스 와전류를 이용한 알루미늄 두께 평가 (Thickness Evaluation of the Aluminum Using Pulsed Eddy Current)

  • 이정기;서동만;이승석
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.15-19
    • /
    • 2005
  • 일반적인 와전류 검사는 단일 주파수 또는 매우 협소한 주파수 대역을 가지는 정현적 신호 사용하며, 알루미늄과 같은 도체에서 피로 균열 같은 결함을 검출하는데 사용되고 있다. 이에 반하여 펄스 와전류는 아주 넓은 주파수 대역폭을 가지는 펄스 신호를 사용한다. 이것은 여러 주파수를 동시에 사용하는 다중 주파수 와전류 검사를 한번에 수행할 수 있도록 하며, 일상적인 와전류 검사에 비하여 침투 깊이를 더 깊게 할 수 있다는 장점이 있다. 본 연구에서는 부식 또는 침식 등에 의한 금속 손실을 평가하기 위한 펄스 와전류 장치를 개발하였다. 개발된 장비는 최대 40 V의 구형 펄스를 발생시키는 펄스 발생기, 수신된 신호를 52 dB까지 증폭하는 증폭기, 16 bit 20MHz의 A/D 변환기, 윈도우 프로그램으로 운영되는 산업용 개인 컴퓨터로 구성하였다. 펄스 와전류 탐촉자는 구동 코일 안에 검출 코일을 삽입한 pancake 형태로 설계 제작하였다. 검출 코일의 출력 신호는 구동 코일에 전압을 끊을 때 갑자기 증가하고 신호의 후반부는 시간에 따라 지수적으로 감소하였으며, 감쇠율을 나타내는 지수 값은 알루미늄 두께가 두꺼울수록 증가하였다.

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

1.0 Tesla 자기 공명 진단 장치의 개발 (Development of 1.0 Tesla Compact MRI System)

  • 이흥규;오창현;안창범;장용호;신동희;이근남;장기현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교 (A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents)

  • 이재승;구은회;박철수;이선엽;최용석
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.235-243
    • /
    • 2009
  • 다양한 간 질환에 Ferucarbotran (SPIO)과 Gd-EOB-DTPA (Primovist) 조영제를 사용하여 자기공명영상 상에서 비교하여 간 질환의 특성 및 검출 과 그 질환에 따른 조영제 흡수관계를 알아보고자 한다. 실험대상은 국소 간 병변을 가진 50명의 환자 중 남자 25명, 여자 25명으로 평균나이는 50세이었다. 사용된 장비와 코일은 3.0T (General Electric Medical System, Excite HD) 자기공명영상장치와 8채널 채부코일이었다. 질환과 조영제 흡수관계를 비교하기 위하여 사용된 펄스 시퀀스는 Liver aquisition with volume acceleration (LAVA)와 Multi-Gradient rapid Echo (MGRE)이었다. 모든 검사기법은 일정한 데이터를 획득하기 위하여 Ferucarbotran (SPIO) 및 Gd-EOB-DTPA (Primovist) 조영제를 주입 전 후에 같은 위치를 선정하여 검사를 시행했다(p<0.05). 검사 결과는 Ferucarbotran와 Gd-EOB-DTPA의 대조도대 잡음비는 간세포암(HCC, 16 cases)이 $3.08{\pm}0.12$$7.00{\pm}0.27$이었다. 과다형성결절(Hyperplastic Nodule, 7 cases) 질환은 $3.62{\pm}0.13$, $2.60{\pm}0.23$, 전이(Metastasis, 13 cases)는 $1.70{\pm}0.09$, $2.60{\pm}0.23$, 초점성 결절성 과증식(Focal Nodular Hyperplasia, 6 cases)질환은 $2.12{\pm}0.28$, $5.86{\pm}0.28$, 농양(Abscess, 8 cases)은 $4.45{\pm}0.28$, $1.73{\pm}0.02$이었다. 또한, 각 질환에 대한 진단적 수행을 위해 ANOVA 검증을 하였다(p<0.05). 결론적으로, 두 조영제 효과로 2개 검사기법 모두가 간질환의 특성 및 검출과 그 질환에 따른 조영제 특성을 잘 보여주었다.

  • PDF