• 제목/요약/키워드: Mu-Scan

검색결과 242건 처리시간 0.024초

전기 수력학 인쇄공정을 이용한 실리콘 태양전지 전극용 Ni 잉크 제조 및 인쇄 공정 연구 (Electrohydrodynamic Continuous Jet Printing of Ni Ink for Crystalline Silicon Solar Cells)

  • 이영우;김지훈
    • 한국전기전자재료학회논문지
    • /
    • 제28권9호
    • /
    • pp.593-597
    • /
    • 2015
  • Ni ink for electrohydrodynamic (EHD) continuous jet printing has been developed by using Ni nanoparticles mixed with conhesiveness provider. EHD continuous jet printing was used in order to realize $20{\mu}m$ pattern width. Ink stability was investigated by using Turbi-scan which monitors agglomeration and precipitation of nanoparticles in the ink for three days. The Turbi-scan results showed that the formulated Ni ink had been stable for 3 days without any indication of precipitation across the entire ink. Antireflection coating (ARC) layer in crystalline solar cell wafers was removed by laser ablation technique leading to the formation of 84 grooves where the Ni ink was printed by EHD continuous jet printing. The printability and microstructure of EHD-jet-printed Ni lines were investigated by using optical and electron microscopes. 84 Ni lines with the width less than $20{\mu}m$ were successfully printed by one-time printing without any misalignment and fill the laser-ablated ARC grooves.

효소 고정화 방법에 따른 콜레스테롤 센서의 감도 특성 (The senstivity characteristics of cholesterol sensor by immobilization methods of the enzyme)

  • 송민정;윤동화;진준형;민남기;홍석인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1935-1937
    • /
    • 2003
  • 최근 콜레스테롤 센서는 전극 상에 효소를 고정화 하는 방식을 이용하여 센서의 집적도를 높이는 시도가 이루어지고 있다. 이러한 전극 상의 효소고정화 방식으로 entrapment, cross liking, covalently binding 등이 있다. 본 논문에서는 이러한 효소 고정화 방식-전도성 고분자인 P3MT를 사용하여 entrap시키는 방법과 silanization을 이용한 covalent bonding 시키는 방법-에 따른 전기화학 센서의 감도 특성에 관한 연구를 수행하였다. 전도성 고분자를 사용한 고정화 방법은 cyclic voltammograms으로 scan rate 10 mA/s, potential 0.5-1.3V의 조건하에서 P3MT를 Polymerization하고, 효소 고정화를 위해 chromoampermeter로 potential 0.6V에서 900초 동안 수행하였다. silanization을 이용한 covalent bonding 시키는 방법은 nitric acid로 Pt 전극표면을 산화시키고, APTER로 silanization 공정을 시행하였다. 효소 고정화를 위해 전해질로는 0.1M Phosphate buffer solution을 사용하여 cyclic voltammograms으로 scan rate 50 mA/s 전위 0.0-0.7V의 조건 하에서 수행하였다. 이 결과 전도성 고분자를 이용한 고정화 방법에서의 senstivity가 0.89 ${\mu}A/mM{\cdot}cm^2$이고, silanization을 이용한 효소 고정화 방법에서는 1.51 ${\mu}A/mM{\cdot}cm^2$였다. 이처럼 후자의 방법에서 더 좋은 감도 특성이 나타났다. 따라서, silanization을 이용한 고정화 방법이 센서 제작 방식으로 더 적합하다고 사료된다.

  • PDF

미세단층촬영기를 이용한 중년 한국인 하악 제1소구치의 내 외부 형태학 연구 (A Study of the Internal and External Morphology in the Mandibular first Premolar of the Middle-Aged Korean Using a Microcomputed Tomography)

  • 전경진;이호중;이종엽
    • 비파괴검사학회지
    • /
    • 제25권4호
    • /
    • pp.254-261
    • /
    • 2005
  • 지금까지 한국인의 치아 통계는 매우 부족한 상태이고, 대부분 치아형태의 정보를 얻기 위해 방사선학적 방법을 이용하거나, 치아를 절단하는 등의 방법으로 연구를 해왔다. 이와 같은 방법은 오랜 시험 기간을 필요로 하고 정밀도가 낮고 파괴적인 방법을 주로 이용한 것이므로, 이제는 한국인의 표준 치아에 대한 정밀한 데이터를 얻기 위해 새로운 비파괴적인 시험이 필요하다. 이를 위하여 각각의 하악 제1소구치를 미세단층촬영기(Micro-CT, SkyScan, Belgium)를 이용하여 $21.31{\mu}m$의 해상도로 교합면에 대한 수평면으로 0.022mm 로 Scan을 하였다. 이를 통하여 내 외부 형태학적 중요부위를 측정하였으며, 영구 치아의 평균 치수표로 사용했었던 G. V. Black(1836-1915)에 의해 제시된 수치와 비교하였다.

펄스길이에 따른 이중편파변수의 민감도 분석 (Sensitivity Analysis of Polarimetric Observations by Two Different Pulse Lengths of Dual-Polarization Weather Radar)

  • 이정은;정성화;김종성;장근일
    • 대기
    • /
    • 제29권2호
    • /
    • pp.197-211
    • /
    • 2019
  • The observational sensitivity of dual-polarization weather radar was quantitatively analyzed by using two different pulse widths. For this purpose, test radar scan strategy which consisted of consecutive radar scan using long (LP: $2{\mu}s$) and short (SP: $1{\mu}s$) pulses at the same elevation angle was employed. The test scan strategy was conducted at three operational S-band dual-polarization radars (KSN, JNI, and GSN) of Korea Meteorological Administration (KMA). First, the minimum detectable reflectivity (MDR) was analyzed as a function of range using large data set of reflectivity ($Z_H$) obtained from JNI and GSN radars. The MDR of LP was as much as 7~22 dB smaller than that of SP. The LP could measure $Z_H$ greater than 0 dBZ within the maximum observational range of 240 km. Secondly, polarimetric observations and the spatial extent of radar echo between two pulses were compared. The cross-polar correlation coefficient (${\rho}_{hv}$) from LP was greater than that from SP at weak reflectivity (0~20 dBZ). The ratio of $Z_H$ (> 0 dBZ) and ${\rho}_{hv}$(> 0.95) bin to total bin calculated from LP were greater than those from SP (maximum 7.1% and 13.2%). Thirdly, the frequency of $Z_H$ (FOR) during three precipitation events was analyzed. The FOR of LP was greater than that of SP, and the difference in FOR between them increased with increasing range. We conclude that the use of LP can enhance the sensitivity of polarimetric observations and is more suitable for detecting weak echoes.

전극함몰형 태양전지의 제조를 위한 레이저 scribing (Laser scribing for buried contact solar cell processing)

  • 조은철;조영현;이수홍
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권6호
    • /
    • pp.593-599
    • /
    • 1996
  • Laser scribing of silicon plays an important role in metallization including the grid pattern and the front surface geometry which means aspect ratio of metal contacts. To make a front metal electrode of buried contact solar cell, we used ND:YAG lasers that deliver average 3-4W at TEM$\_$00/ mode power to sample stage. The Q-switched Nd:YAG laser of 1.064 gm wavelength was used for silicon scribing with 20-40.mu.m width and 20-200.mu.m depth capabilities. After silicon slag etching, the groove width and depth for buried contact solar cell are -20.mu.m and 30-50.mu.m respectively. Using MEL 40 Nd:YAG laser system, we can scribe the silicon surface with 18-23.mu.m width and 20-200.mu.m depth controlled by krypton arc lamp power, scan speed, pulse frequency and beam focusing. We fabricated a buried contact Silicon Solar Cell which had an energy conversion efficiency of 18.8 %. In this case, the groove width and depth are 20.mu.m and 50.mu.m respectively.

  • PDF

하이드로겔 렌즈와 실리콘-하이드로겔 렌즈가 각막 두께에 미치는 영향 (Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness)

  • 서정익
    • 한국임상보건과학회지
    • /
    • 제5권4호
    • /
    • pp.1021-1025
    • /
    • 2017
  • Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied. Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan II(ver. 3.14) Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was $33.63{\mu}m$, the nasal was $34.29{\mu}m$, the temporal was $27.17{\mu}m$, the inferior was $27.17{\mu}m$, the superior was $18.90{\mu}m$, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was $33.63{\mu}m$, the mid-peripheral was $28.19{\mu}m$, the peripheral was $24.18{\mu}m$, and change rates were 6.28%, 4.76%, and 3.79%, respectively. Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.

밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향 (Effect of milling tool wear on the internal fit of PMMA implant interim prosthesis)

  • 신미선
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.63-69
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the effect of CAD/CAM system milling tool wear on the marginal and internal fit of PMMA implant interim prosthesis three-dimensional manner. Methods: A total of 20 crowns were fabricated with CAD/CAM method. Their designs were unified to first molar of the left maxilla. The Customized abutments were prepared and scanned with on optical model scanner. Five crowns were milled by the newly replaced tool (1st milling), and 15 crowns were milled by 2nd, 3rd, 4th milling tool. The marginal and internal fit of 20 interim crowns were measured using the triple-scan protocol. Results: Statistically significant difference was found between the $1^{st}$ milling group ($51.8{\pm}14.6{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($128.6{\pm}43.8{\mu}m$, $146.2{\pm}38.1{\mu}m$, respectively) at the distal margins. In the mesial margins, There was a statistically significant difference between the $1^{st}$ milling group ($63.6{\pm}25.9{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($137.2{\pm}25.9{\mu}m$, $186.8{\pm}70.6{\mu}m$, respectively). In the distal line angle, significant difference was found between the $1^{st}$, $2^{nd}$, $3^{rd}$ milling groups and the $4^{th}$ milling group. In the mesial axial wall, significant difference was found between the $1^{st}$ milling group ($52.2{\pm}20.3{\mu}m$) and the $3^{rd}$, $4^{th}$ milling groups ($22.8{\pm}8.8{\mu}m$, $7.8{\pm}5.7{\mu}m$). Conclusion: As a result of the experiment, decrease of the marginal and internal fit was statistically significant as the number of machining cycles increased. In order to produce clinically excellent restorations, it is recommandable to consider the condition of the milling tool wear, when designing the restoration with CAD program.

심장풀스캔에서 방사능 계측법에 의한 좌심실 용적의 측정 -조직 감쇄의 보정에 의한 연구- (Left Ventricular Volume Measurement by Count Method with Attenuation Correction in Gated Blood Pool scan)

  • 범희승;정준기;이명철;조보연;고창순;김지열
    • 대한핵의학회지
    • /
    • 제21권1호
    • /
    • pp.33-37
    • /
    • 1987
  • Attenuated end-diastolic and end-systolic left ventricular counts which obtained from cardiac gated blood pool scan were corrected using experimentally calculated attenuation coefficient $(\mu=0.13/cm)$ and depth of center of left ventricle. This method was confirmed to be correct experimentally using phantom balloon. To compare the accuracy of attenuated and attenuation-corrected left ventricular volume measurement, authors studied 10 patients with ischemic heart disease who underwent both gated blood pool scan and X-ray contrast ventriculography within a week. The attenuated and attenuation-corrected left ventricular volume measured by count method correlated with contrast ventriculographic volumes; however, attenuation corrected measurement was correlated more closely.

  • PDF

광간섭 단층촬영법을 이용한 우량 참외 종자 실시간 감별 시스템 개발 (Development of Real-time Screening System for Superior Melon Seeds Using Optical Coherence Tomography)

  • 한승훈;이창호;이승열;정희영;김지현
    • 센서학회지
    • /
    • 제22권4호
    • /
    • pp.262-267
    • /
    • 2013
  • We developed a real-time screening system using optical coherence tomography (OCT) to distinguish the fruitful melon seeds efficiently. Cross-section images of melon seeds infected with Cucumber green mottle mosaic virus (CGMMV) showed an additional layer that did not appear in normal seeds. Additional layer appeared under $100{\sim}300{\mu}m$ from the surface of the seed. OCT can visualize the micro-structural and morphological changes of the internal seed structure. Real-time OCT seed screening system provided the real-time, non-destructive, cross-section image and quantitative information such as A-scan analysis of selected region in the cross-section image. We can distinguish the viral infection seeds while monitoring the averaged A-scan analysis graph in real-time by considering the second peak value of the graph which refers to the layer that occurred owing to the virus. Real-time OCT seed screening system could assist to distinguish the disease caused by CGMMV.

3차원 모바일 그래픽 응용을 위한 스캔 변환 프로세서의 설계 (Design of Scan Conversion Processor for 3-Dimensional Mobile Graphics Application)

  • 최병윤;하창수
    • 한국정보통신학회논문지
    • /
    • 제11권11호
    • /
    • pp.2107-2115
    • /
    • 2007
  • 본 논문에서는 3개의 정점으로 표현된 삼각형을 화면 좌표, 깊이 좌표, 색 등의 픽셀 정보로 바꾸는 스캔 변환 프로세서를 설계하였다. 설계된 스캔 변환 회로는 삼각형 변을 따라 스팬 라인을 생성한 후, 스팬 라인을 픽셀로 변환하는 스캔 라인 방식을 사용하였다. 그리고 좌변-상변 픽셀 채움 규칙을 지원함에 의해서 인접한 삼각형의 공유 변에 대한 픽셀이 중복 처리와 미처리 되는 것을 방지한다. 스캔 변환 프로세서 는 약 21,400개의 게이트로 구성되며, $0.35{\mu}m$ CMOS 공정 조건에서 약 80 Mhz의 동작 주파수를 가진다. 스캔 변환 프로세서는 최대 80 Mpixels/sec의 픽셀 생성 율을 갖고 있어 3차원 모바일 그래픽 분야에 적용 가능하다.