Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

사이버나이프에서 폐종양 추적 시스템의 정확도 분석 (Verification of X-sight Lung Tracking System in the CyberKnife)

  • 허현도;최상현;김우철;김헌정;김성훈;조삼주;민철기;조광환;이상훈;최진호;임상욱;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제20권3호
    • /
    • pp.174-179
    • /
    • 2009
  • 사이버나이프 로봇 방사선 수술 시스템은 환자를 치료하는 동안 환자의 내부 기준 마커를 이용하여 종양의 위치를 실시간으로 추적 할 수 있는 시스템이다. 최근 폐종양 치료의 경우 기준 마커의 삽입 없이 폐종양의 밀도 차이를 이용하여 실시간 종양 추적을 할 수 있는 폐종양추적시스템이 개발되어 치료에 적용되고 있다. 최근 개발되어 국내 최초 도입된 폐종양 추적치료시스템의 위치 추적 정확도의 분석은 동적흉부 팬톰과 GafChromic film을 이용하였다. 폐종양추적시스템을 이용하여 종양의 위치 추적 정확도는 평균 오차 $0.85{\pm}0.22$ mm로 분석되었다. 기준마커 삽입 없이 폐종양추적시스템을 이용하여 폐종양 치료에 매우 유용한 것으로 판단되었다.

  • PDF

자체 제작한 QA Phantom을 이용한 양성자 PPS (Patient Positioning System)의 정확성 평가 (Evaluation on the Accuracy of the PPS in the Proton Therapy System, Which Uses the Self Made QA Phantom)

  • 이지은;김재원;강동윤;최재혁;염두석
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.115-121
    • /
    • 2012
  • 목 적: 양성자 치료는 DIPS (Digital Imaging Positioning System)를 이용하여 기준이 되는 DRR (Digital Reconstruction Radiography) 영상과 당일 치료 과정에서 얻은 X-ray 영상의 해부학적 구조를 비교하여 교정 값을 얻어 PPS (Patient Positioning System)를 교정 후 치료한다. PPS는 환자 셋업의 정확성을 위해 6방향(X축 Lateral, Y축 Longitudinal, Z축 Vertical, Rotation, Pitch, Roll)의 이동을 기반으로 움직인다. 따라서 DIPS의 교정 값과 PPS 움직임 구현성의 정확성 평가가 필요하다. 이에 자체 제작한 PPS QA 팬텀을 이용하여 PPS의 정확성을 평가하고자 한다. 대상 및 방법: 환자의 해부학적 구조를 대신 할 납 볼이 부착된 PPS QA 팬텀을 기준점에 셋업 한다. 임의의 수치 값으로 PPS 6 방향의 움직임을 만들어 PPS QA 팬텀을 이동시킨다. DIPS로 얻은 교정 값을 적용 후 기준점과 기준점으로 돌아온 PPS QA 팬텀과의 교정 값이 허용 범위 내에 들어오는지 평가한다. 결 과: 기준점에 위치한 PPS QA 팬텀의 X축, Y축, Z축의 3개의 좌표를 함께 1 cm에서 5 cm까지 1 cm씩 이동한 후 기준점과의 평균 교정 값은 PPS 6축에서 각각 0.04 cm, 0.026 cm, 0.022 cm, $0.22^{\circ}$, $0.24^{\circ}$, $0^{\circ}$이다. PPS QA 팬텀의 6방향의 이동 좌표계를 모두 1과 2만큼 이동 시켰을 때 평균 교정 값은 1 이동 시 0.06 cm, 0.01 cm, 0.02 cm, $0.1^{\circ}$, $0.3^{\circ}$, $0^{\circ}$이었고, 2만큼 이동 시에 0.02 cm, 0.04 cm, 0.01 cm, $0.3^{\circ}$, $0.5^{\circ}$, $0^{\circ}$이었다. 결 론: 교정 값을 평가한 결과 Lateral, Longitudinal, Vertical의 경우 허용 범위인 0.5 cm Rotation, Pitch, Roll의 경우 허용 범위 $1^{\circ}$ 안에 모두 들어오는 것을 알 수 있었다. 하지만 더욱 정확한 양성자 치료를 위해 DIPS의 이미지 질 개선과 DIPS 매칭 시스템의 발전 노력, 정기적인 장비 관리를 함으로써 현재 발생하는 기계적인 오차를 더욱 줄여나가야 하겠다.

  • PDF

Geant4 코드를 사용한 인체팬텀 선량평가 검증 (Verification of Dose Evaluation of Human Phantom using Geant4 Code)

  • 장은성;최지훈
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.529-535
    • /
    • 2020
  • Geant4는 C++ 언어사용에서 windows 운영체계와 호환이 가능해져, DICOM이나 소프트웨어를 연계하는 인터페이스 기능이 가능해졌다. 기하학적 고형물에 의해 인체 장기를 나타내는 팬텀은 치료나 진단에서 선량 계획과 같은 의학 용도에 널리 사용된다 방사선 방호 목적을 위해서는 에너지가 몇 keV의 일때 설명의 유효성을 보여주는 것일 여전히 필요하다. 본 연구에서는 Geant4 시뮬레이션을 통해 저 keV부터 고 keV까지 다양하게 에너지를 선택하여 인간 팬텀중 일부분을 선택하여 광자 병렬 평면 필드에서 조사했을 때 그 장기에 대한 방사선량을 구하고 Zankl의 승인된 방법에 의해 얻은 결과에 대해 결과를 비교 검증하고자 한다. 몬테카롤로 코드를 사용하여 장기 선량을 평가하는 것의 중요성은 시뮬레이션의 다양한 묘사 및 특성에 의해 중성자, 양성자, 파온 등과 같은 빔의 여러 가지 유형의 입자와 Gev와 같은 높은 에너지에도 적합하다는 것을 확인하였다.

IVR장치의 성능 평가 기준 개발 (Establishment of Quality Control System for Angiographic Unit)

  • 강병삼;손진현;김승철
    • 한국콘텐츠학회논문지
    • /
    • 제11권1호
    • /
    • pp.236-244
    • /
    • 2011
  • 성능이 저하된 IVR 장치의 지속적 사용은 환자 및 시술자의 방사선 피폭을 증가시킬 뿐 아니라, 잘못된 영상정보를 제공함으로써 환자에게 심각한 영향을 끼칠 수 있다. 따라서 이번 연구에서는 IVR장치의 성능평가를 위한 적절한 시험방법 및 검사기준을 마련하고자 하였다. IVR장치의 국내현황 및 규격을 조사하였으며, 표준팬텀을 이용하여 국내 IVR장치의 성능을 현장 측정함으로써, 국내 실정에 맞는 적절한 IVR 장치의 화질 및 성능평가 기준을 설정하였다. 장치의 기본적 성능에 관한 검사를 위해 관전압시험, 관전류 시험, 반가층 시험을 실시하며, NEMA stndard XR-21 Phantom을 표준팬텀으로 사용하여 화질 및 선량 평가를 하도록 하였다. 표준팬텀을 이용한 검사항목은 image-field geometry, spatial resolution, low-contrast iodine detectability, wire resolution, phantom entrance dose이다. 또한 매일, 매주, 1개월, 3개월, 6개월 및 1년 주기의 평가항목을 설정하였다. 장치의 성능기준은 진단용방사선안전관리 규정을 준용하여 kVp시험은 평균오차 ${\pm}10%$, mA시험은 평균오차 ${\pm}15%$, 반가층시험은 80kVp에서 최소 2.3mmAl으로 설정하였다. 표준팬텀의 검사기준은 image-field geometry에서 최소 acceptable이 나와야 하며, spatial resolution은 Image Intensifier 나 detector 크기기준으로 34-40cm은 0.8 lp/mm, 28-33cm은 1.0lp/mm, 22-27cm은 1.2 lp/mm이상이 나와야 한다. low contrast iodine detectability는 최소농도 200mg/cc 이상 보여야 하며, phantom entrance dose는 10R/min을 초과해서는 안 된다. Wire resolution은 정지 상태에서 최소 0.012인치까지 보여야 하며, 움직일 때 최소 0.022인치까지 보여야 한다.

핵자기 공명 영상에서 새로운 유속 흐름제거 방법 (Novel Flow Suppression Technique in MRI)

  • 노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.92-97
    • /
    • 1992
  • The pulsatile nature of blood flow makes artefacts in 2D Fourier transform image. Spatial presaturation is known to be effective in eliminating flow artefacts when the spin echo acquisition is employed. However. this method requires additional RF pulse and spoiling gradient for presaturation. In this paper a new flow saturation technique which does not require additional saturation-RF and gradient is proposed. The proposed technique is equivalent to the existing saturation technique but the elimination of the flow component is achieved by a pair of tailored $90^{\circ}-180^{\circ}$ RF pulses in tile spin echo sequence. By use of two tailored RF pulses with opposite phase polarity, a linear phase gradient is generated for those moving materials and consequently all the spins of moving materials become dephased thereby no signal is observable. Computer simulations and experimental results obtained using both a phantom and a human volunteer with a 2.0 T whole body system are also presented.

  • PDF

완전 데이터 적응형 MLS 근사 알고리즘을 이용한 Interleaved MRI의 움직임 보정 알고리즘 (Motion Artifact Reduction Algorithm for Interleaved MRI using Fully Data Adaptive Moving Least Squares Approximation Algorithm)

  • 남혜원
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.28-34
    • /
    • 2020
  • In this paper, we introduce motion artifact reduction algorithm for interleaved MRI using an advanced 3D approximation algorithm. The motion artifact framework of this paper is data corrected by post-processing with a new 3-D approximation algorithm which uses data structure for each voxel. In this study, we simulate and evaluate our algorithm using Shepp-Logan phantom and T1-MRI template for both scattered dataset and uniform dataset. We generated motion artifact using random generated motion parameters for the interleaved MRI. In simulation, we use image coregistration by SPM12 (https://www.fil.ion.ucl.ac.uk/spm/) to estimate the motion parameters. The motion artifact correction is done with using full dataset with estimated motion parameters, as well as use only one half of the full data which is the case when the half volume is corrupted by severe movement. We evaluate using numerical metrics and visualize error images.

인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가 (Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom)

  • 장은성;강수만;이철수
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.33-39
    • /
    • 2009
  • 목 적: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하면 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. Detected offsets은 실제로 적용된 인체팬톰(Rando phantom) 위치의 오차와 비교되어 진다. 이후, 인체 팬톰은 detected 오차에 근거하여 couch를 움직여 위치선정 되었다. 또한 인체팬톰 위치 결정의 실측값과 이론값 오차값들을 비교하였으며, OBI를 사용하고 있는 KV X선영상의 2D와 CBCT의 3D 타켓 위치 정확성 평가하고자 한다. 대상 및 방법: 신체 내부 구조가 모사된 팬톰(The Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)을 사용하여 실제방사선 치료와 동일한 과정을 따라 모의치료(SIMULATION) 및 치료계획(RTP)을 시행한 후 치료 데이블 위에 인체 팬톰을 셋업한다. 정확히 위치가 재현된다고 가정되는 인체팬톰에 대해 3가지 방법으로 실험을 했는데 X, Y, Z축의 변화에 따라 셋업 오차를 측정했고 각각의 실험은 10회씩 반복되어 오차의 표준 편차를 구했다. DigiPas DWL-80G는 기울기의 각을 결정하기 위해 사용하였으며, 2D/2D 및 3D/3D정합의 실측치와 측정치를 비교 분석 하였다. 결 과: 온보드 영상장치로 획득한 정면 및 측면 kv x선 영상과 모의치료시 디지털 재구성 기준영상과의 2차원/2차원 정합시, 팬톰의 X, Y, Z 편차 평균값은 lat 0.12 cm, long -0.66 cm, vert 0.07 cm이며, 각도의 변화를 주었을 때 편차의 평균값은 lat -0.5 cm, long -0.3 cm, 팬톰의 몸을 약간 튼 상태에서의 편차 평균값은 각각 lat -0.5 cm, long 0.2 cm, vert -0.6 cm으로 나타났다. 또한 콘빔CT로 획득한 영상과 모의치료 시 획득한 CT영상을 비교하는 3차원/3차원 정합에서 팬톰의 3가지 방법에서 편차의 평균 detection error와 표준편차는 lateral $0.5{\pm}0.4\;mm$, longitudinal $0.8{\pm}0.5\;mm$, vertical $0.4{\pm}0.3\;mm$로 각각 0-10 mm의 범위이다. Residual error에 해당되는 positioning couch shift 변수는 $0.6{\pm}0.3\;mm$, $0.5{\pm}0.3\;mm$, $0.3{\pm}0.1\;mm$이다. 20-50 mm까지 longitudinal shift에 의한 평균 detection error는 각각 lateral $0.4{\pm}0.2\;mm$, longitudinal $0.3{\pm}0.2\;mm$, vertical $0.3{\pm}0.3\;mm$이다. Residual error는 $0.6{\pm}0.3\;mm$, $0.6{\pm}0.2\;mm$, $0.4{\pm}0.1\;mm$이다. Detection error는 모두 0.0~0.6 mm 범위이다. Residual error는 0.3~0.9 mm 범위로 나타났다. 결 론: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하여 표적위치의 정확성을 평가하였다. 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. 그러므로 OBI 및 CBCT를 이용한 2D/2D 및 3D/3D 정합은 모의 치료 시와 환자 치료 시 정확한 정합을 함으로써 error를 최소화 할 것으로 평가된다.

  • PDF

2.45 GHz On-Body 시스템에서 인체 내부 장기에 따른 채널 모델 특징 연구 (Study of Channel Model Characterization of Human Internal Organ in On-Body System at 2.45 GHz)

  • 전재성;최재훈;김선우
    • 한국전자파학회논문지
    • /
    • 제25권1호
    • /
    • pp.62-69
    • /
    • 2014
  • 본 논문에서는 WBAN(Wireless Body Area Network) On-body 시스템에서 표면 지향 안테나를 사용하여 인체 내부 기관에 의한 영향을 분석하였다. 인체 내부 기관의 영향을 확인하기 위하여 인체 상반신 모델과 실제 인체에 안테나를 부착하여 수신 신호의 세기를 측정하였다. 실험은 인체에 대한 고유 영향을 보기 위하여 무반향실에서 움직임 없이 수행하였고, VNA(Vector Network Analyzer)를 이용하여 수신 신호 세기를 측정하였다. 측정된 데이터를 이용하여 인체 모델과 상반신 모델의 수신 신호 세기를 비교하였고, 인체 내부 기관이 안테나 수신 신호 세기에 미치는 효과를 분석하였다.

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF