• 제목/요약/키워드: Moving average filter (MAF)

검색결과 8건 처리시간 0.026초

Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

  • Han, Yang;Luo, Mingyu;Chen, Changqing;Jiang, Aiting;Zhao, Xin;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1904-1917
    • /
    • 2016
  • The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of phase-locked loops (PLLs). This is of vital significance for the grid-integration and stable operation of power electronic converters to electric power systems. However, the open-loop bandwidth is drastically reduced after incorporating a MAF into the PLL structure, which makes the dynamic response sluggish. To overcome this shortcoming, some new techniques have recently been proposed to improve the transient response of MAF-based PLLs. In this paper, a comprehensive performance comparison of advanced MAF-based PLL algorithms is presented. This comparison includes HPLL, MPLC-PLL, QT1-PLL, and DMAF-PLL. Various disturbances, such as grid voltage sag, voltage flicker, harmonics distortion, phase-angle and frequency jumps, DC offsets and noise, are considered to experimentally test the dynamic performances of these PLL algorithms. Finally, an improved positive sequence extraction method for a HPLL under the frequency jumps scenario is presented to compensate for the steady-state error caused by non-frequency adaptive DSC, and a satisfactory performance has been achieved.

A Hybrid Filtering Stage Based Quasi-type-1 PLL under Distorted Grid Conditions

  • Li, Yunlu;Wang, Dazhi;Han, Wei;Sun, Zhenao;Yuan, Tianqing
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.704-715
    • /
    • 2017
  • For three-phase synchronization applications, the synchronous reference frame phase-locked loop (SRF-PLL) is probably the most widely used technique due to its ease of implementation and satisfactory phase tracking performance under ideal grid conditions. However, under unbalanced and distorted grid conditions, its performance tends to worsen. To deal with this problem, a variety of filtering stages have been proposed and used in SRF-PLLs for the rejection of disturbance components at the cost of degrading the dynamic performance. In this paper, to improve dynamic performance without compromising the filtering capability, an effective hybrid filtering stage is proposed and incorporated into the inner loop of a quasi-type-1 PLL (QT1-PLL). The proposed filtering stage is a combination of a moving average filter (MAF) and a modified delay signal cancellation (DSC) operator in cascade. The time delay caused by the proposed filtering stage is smaller than that in the conventional MAF-based and DSC-based PLLs. A small-signal model of the proposed PLL is derived. The stability is analyzed and parameters design guidelines are given. The effectiveness of the proposed PLL is confirmed through experimental results.

Heart Rate Estimation Based on PPG signal and Histogram Filter for Mobile Healthcare

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of information and communication convergence engineering
    • /
    • 제8권1호
    • /
    • pp.112-115
    • /
    • 2010
  • The heart rate is the most important vital sign in diagnosing heart status. The simple method to measure the heart rate in the mobile healthcare device is using the PPG signal. In developing the mobile healthcare device using the PPG signal, the most important issue is the inaccuracy of the measured heart rate because the PPG signal is distorted from the user's motions. To improve the problem, this study proposed the new method that is to estimate the heart rate without an additional sensor in real life. The proposed method in this study is using the histogram filter. In order to evaluate the performance of the proposed method, the study compares its results with the moving average method in motion environment. According to the experimental results, the performance of the proposed method was more than 40% better than the performances of the MAF.

Design and Implementation of a Robust Predictive Control Scheme for Active Power Filters

  • Han, Yang;Xu, Lin
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.751-758
    • /
    • 2011
  • This paper presents an effective robust predictive control scheme for the active power filter (APF) using a smith-predictor based current regulator, which show superior features when compared to proportional-integral (PI) controllers in terms of an enhanced closed-loop bandwidth and an improved current tracking accuracy. A moving average filter (MAF) is implemented using a field programmable gate array (FPGA) for signal pre-processing to eliminate the switching ripple contamination. An adaptive linear neural network (ADALINE) is used for individual harmonic estimation to achieve selective compensation purpose. The effectiveness and validity of the devised control algorithm are confirmed by extensive simulation and experimental results.

차량 주행 상태에 따른 연료량 유동의 안정 지침에 대한 연구 (A Study on Stable Indication for a Sloshing of Fuel-quantity according to Driving State of Vehicle)

  • 허진;박종명;이선봉
    • 한국자동차공학회논문집
    • /
    • 제20권3호
    • /
    • pp.37-44
    • /
    • 2012
  • In this paper, the application of robust fuel gauge algorithm in the external environment to general fuel gauge system is proposed. The proposed fuel gauge system is composed of two modules which are Moving Average Filter (MAF) and Inclination Filter (IF). They are used to show correctly the amount of fuel in the external environment which are curve road, slope or acceleration/deceleration driving. In parallel, verification and validation processes using Software In the Loop Simulation (SILS) in personal computer and Hardware In the Loop Simulation (HILS) similar to actual vehicle environments are established. Through this research, it turned out to be possible to operation of gauge become correct of external environment.

MBOK DS-UWB 시스템을 위한 주파수 영역 등화기 알고리즘의 설계 (Design of a Frequency Domain Equalizer Algorithm for MBOK DS-UWB System)

  • 강신우;임세빈;최형진
    • 한국통신학회논문지
    • /
    • 제32권10A호
    • /
    • pp.1034-1041
    • /
    • 2007
  • 본 논문에서는 고속 무선 통신을 위한 IEEE 802.15.TG3a PHY proposal 중에서 MBOK DS-UWB (M-ary bi-orthogonal keying direct sequence UWB) 시스템의 수신기를 위한 개선된 방식의 FD MMSE (frequency domain minimum mean square error) equalizer 알고리즘을 제안한다. 기존 FD MMSE equalizer 알고리즘에서는 모든 전송 패킷에 CP (cyclic prefix)를 삽입해야 하므로 일반적인 SC (single carrier) 시스템에 적용할 경우 구조적인 제한이 발생한다. 본 논문에서는 이러한 문제점을 해결하기 위해 CP를 사용하지 않는 FD MMSE equalizer 알고리즘을 제안하였으며, 보다 정확한 채널 추정 및 보상을 위하여 MAF (moving average filter) 및 moving FFT 기법을 사용하여 수신 성능의 안정성을 증대시킴으로써 실내 무선 채널 환경에 보다 적합하도록 설계하였다. IEEE 802.15.TG3a 무선 채널 모델 환경에서의 성능 평가를 수행하고 일반적인 FDE 및 TD (time domain) MMSE-RAKE 수신기와의 성능 비교를 통해, 제안한 FD MMSE equalizer 알고리즘의 우수성을 입증하였다.

섬유근접센서를 이용한 장기투약자의 복약 관리 시스템 기초 연구 (A Preliminary Study on the Medication Management System of the Patients Requiring a Long-term using Textile Proximity Sensor)

  • 임도휘;호종갑;유수한;이유정;민세동
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 춘계학술발표대회
    • /
    • pp.883-886
    • /
    • 2016
  • 본 논문에서는 장기투약자의 복약 관리 시스템 개발의 기초 연구로 Textile proximity pressure sensor를 개발하였고, 약통의 무게 감지를 통하여 약의 복용 여부를 판별하는 연구를 수행하였다. 실험은 총 2가지로, 약의 개수에 따른 baseline검출 실험과 약 한알의 무게 도출 실험을 수행하였다. 잡음을 제거하기 위해 5 point의 이동평균필터(MAF: Moving average filter)를 적용하였다. 본 논문을 통해 얻은 결과는 차후 장기 투약이 필요한 환자로 하여금 규칙적으로 약을 복용하도록 하여 만성질환의 완치율을 높이는 데 기여할 수 있을 것으로 판단된다.

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF