• Title/Summary/Keyword: Moving average filter (MAF)

Search Result 8, Processing Time 0.021 seconds

Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

  • Han, Yang;Luo, Mingyu;Chen, Changqing;Jiang, Aiting;Zhao, Xin;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1904-1917
    • /
    • 2016
  • The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of phase-locked loops (PLLs). This is of vital significance for the grid-integration and stable operation of power electronic converters to electric power systems. However, the open-loop bandwidth is drastically reduced after incorporating a MAF into the PLL structure, which makes the dynamic response sluggish. To overcome this shortcoming, some new techniques have recently been proposed to improve the transient response of MAF-based PLLs. In this paper, a comprehensive performance comparison of advanced MAF-based PLL algorithms is presented. This comparison includes HPLL, MPLC-PLL, QT1-PLL, and DMAF-PLL. Various disturbances, such as grid voltage sag, voltage flicker, harmonics distortion, phase-angle and frequency jumps, DC offsets and noise, are considered to experimentally test the dynamic performances of these PLL algorithms. Finally, an improved positive sequence extraction method for a HPLL under the frequency jumps scenario is presented to compensate for the steady-state error caused by non-frequency adaptive DSC, and a satisfactory performance has been achieved.

A Hybrid Filtering Stage Based Quasi-type-1 PLL under Distorted Grid Conditions

  • Li, Yunlu;Wang, Dazhi;Han, Wei;Sun, Zhenao;Yuan, Tianqing
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.704-715
    • /
    • 2017
  • For three-phase synchronization applications, the synchronous reference frame phase-locked loop (SRF-PLL) is probably the most widely used technique due to its ease of implementation and satisfactory phase tracking performance under ideal grid conditions. However, under unbalanced and distorted grid conditions, its performance tends to worsen. To deal with this problem, a variety of filtering stages have been proposed and used in SRF-PLLs for the rejection of disturbance components at the cost of degrading the dynamic performance. In this paper, to improve dynamic performance without compromising the filtering capability, an effective hybrid filtering stage is proposed and incorporated into the inner loop of a quasi-type-1 PLL (QT1-PLL). The proposed filtering stage is a combination of a moving average filter (MAF) and a modified delay signal cancellation (DSC) operator in cascade. The time delay caused by the proposed filtering stage is smaller than that in the conventional MAF-based and DSC-based PLLs. A small-signal model of the proposed PLL is derived. The stability is analyzed and parameters design guidelines are given. The effectiveness of the proposed PLL is confirmed through experimental results.

Heart Rate Estimation Based on PPG signal and Histogram Filter for Mobile Healthcare

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.1
    • /
    • pp.112-115
    • /
    • 2010
  • The heart rate is the most important vital sign in diagnosing heart status. The simple method to measure the heart rate in the mobile healthcare device is using the PPG signal. In developing the mobile healthcare device using the PPG signal, the most important issue is the inaccuracy of the measured heart rate because the PPG signal is distorted from the user's motions. To improve the problem, this study proposed the new method that is to estimate the heart rate without an additional sensor in real life. The proposed method in this study is using the histogram filter. In order to evaluate the performance of the proposed method, the study compares its results with the moving average method in motion environment. According to the experimental results, the performance of the proposed method was more than 40% better than the performances of the MAF.

Design and Implementation of a Robust Predictive Control Scheme for Active Power Filters

  • Han, Yang;Xu, Lin
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.751-758
    • /
    • 2011
  • This paper presents an effective robust predictive control scheme for the active power filter (APF) using a smith-predictor based current regulator, which show superior features when compared to proportional-integral (PI) controllers in terms of an enhanced closed-loop bandwidth and an improved current tracking accuracy. A moving average filter (MAF) is implemented using a field programmable gate array (FPGA) for signal pre-processing to eliminate the switching ripple contamination. An adaptive linear neural network (ADALINE) is used for individual harmonic estimation to achieve selective compensation purpose. The effectiveness and validity of the devised control algorithm are confirmed by extensive simulation and experimental results.

A Study on Stable Indication for a Sloshing of Fuel-quantity according to Driving State of Vehicle (차량 주행 상태에 따른 연료량 유동의 안정 지침에 대한 연구)

  • Hur, Jin;Park, Jong-Myeong;Lee, Seon-Bong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.37-44
    • /
    • 2012
  • In this paper, the application of robust fuel gauge algorithm in the external environment to general fuel gauge system is proposed. The proposed fuel gauge system is composed of two modules which are Moving Average Filter (MAF) and Inclination Filter (IF). They are used to show correctly the amount of fuel in the external environment which are curve road, slope or acceleration/deceleration driving. In parallel, verification and validation processes using Software In the Loop Simulation (SILS) in personal computer and Hardware In the Loop Simulation (HILS) similar to actual vehicle environments are established. Through this research, it turned out to be possible to operation of gauge become correct of external environment.

Design of a Frequency Domain Equalizer Algorithm for MBOK DS-UWB System (MBOK DS-UWB 시스템을 위한 주파수 영역 등화기 알고리즘의 설계)

  • Kang, Shin-Woo;Im, Se-Bin;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10A
    • /
    • pp.1034-1041
    • /
    • 2007
  • In this paper, we propose a FD USE (frequency domain minimum mean square error) equalizer algorithm for MBOK DS-UWB (M-ary bi-orthogonal keying direct sequence UWB) systems considered as a PHY proposal for high-speed wireless communication in IEEE 802.15.TG3a. The conventional FD MMSE equalization scheme has a structural limit due to insertion of the cyclic prefix (CP) in all transmit packets, but the proposed scheme is able to equalize the channel effect without CP. In order to overcome channel estimation error by multipath delay, we introduce a moving FFT and a moving average scheme. Compared with conventional FD MMSE equalizer and the traditional TD (time domain) MMSE-RAKE receiver, the proposed FD MMSE equalizer has better BER performance and we demonstrate this result by computer simulation.

A Preliminary Study on the Medication Management System of the Patients Requiring a Long-term using Textile Proximity Sensor (섬유근접센서를 이용한 장기투약자의 복약 관리 시스템 기초 연구)

  • Im, Do Hwi;Ho, JongGab;Yoo, Su Han;Lee, Yoo Jung;Min, Se Dong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.883-886
    • /
    • 2016
  • 본 논문에서는 장기투약자의 복약 관리 시스템 개발의 기초 연구로 Textile proximity pressure sensor를 개발하였고, 약통의 무게 감지를 통하여 약의 복용 여부를 판별하는 연구를 수행하였다. 실험은 총 2가지로, 약의 개수에 따른 baseline검출 실험과 약 한알의 무게 도출 실험을 수행하였다. 잡음을 제거하기 위해 5 point의 이동평균필터(MAF: Moving average filter)를 적용하였다. 본 논문을 통해 얻은 결과는 차후 장기 투약이 필요한 환자로 하여금 규칙적으로 약을 복용하도록 하여 만성질환의 완치율을 높이는 데 기여할 수 있을 것으로 판단된다.

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF