• Title/Summary/Keyword: Moving Device

Search Result 653, Processing Time 0.031 seconds

A Study of PPG Wave and Pulse Measurement on Radial Artery Using Digital Potentiometer and Exponentially Weighted Moving Average Filter (디지털 가변저항과 지수가중 이동평균필터를 통한 요골동맥에서의 PPG 파형과 맥박 측정에 관한 연구)

  • Jung, In-Bok;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.962-967
    • /
    • 2014
  • In this paper, through a digital potentiometer and exponentially weighted moving average filter, pulse and PPG waveform measurable device was fabricated in radial artery. If this device is not proper about signal size in analog part, MCU can judge easily by adjusted amplification through digital potentiometer, using exponentially weighted moving average filter is able to filter out more clear value of ADC. I presumed pulse rate as value of measuring time between point of maximum contraction from sensing signal in radial artery of wrist. Therefore, this means can measure stable pulse rate and PPG waveform, finger as well as radial artery, whether signal size of each person is different finger as well as radial artery.

Dynamic behavior of a scroll compressor with radial compliance device (반경방향 순응기구를 갖는 스크롤 압축기의 동적 거동)

  • 김현진;김재호;이진갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.33-43
    • /
    • 1998
  • Dynamic behavior of a scroll compressor has been investigated analytically. The equations of motion of moving elements of the scroll compressor such as the orbiting scroll, anti-rotation device, slider bush, and the crank shaft with eccentric crank pin have been set up. As the solutions of these equations, reaction forces between the moving elements, and also between the moving elements and the compressor frame have been calculated. The reaction forces from the moving elements to the frame are the unbalanced forces, which produce accelerations of the compressor body. These accelerations can be used as a measure of the compressor vibration. The major contributions to the unbalanced forces come from the orbiting movement of the orbiting scroll.

  • PDF

A Study of External Storage Device File Outflow (외장형 저장장치의 파일유출에 관한 연구)

  • Song, Yu-Jin;Lee, Jae-Yong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.2
    • /
    • pp.59-64
    • /
    • 2011
  • A lot of computer users use external memory device. But, same time file efflux incidents are also increasing. There are two ways people use for efflux file. One is moving it after checking file which is running on computer and the other is checking file name only. Checking from running file case, we can identify vestige with running information of applied program but, the case of moving as external device without running file there is no evidence running applied program. So there are a lot of difficulty with forensic investigation. In this paper we suggest the way to help forensic investigation which is method of getting external memory device information of volume and time through its awareness method and connection information and moving to external device without running file after compare the external memory device volume information through link file analysis and getting information of link file formation & access time from link file.

Development of a Robotic Transplanter for Pot-Seedlings of Plant Factory (식물공장용 포트묘 로봇 이식기 개발)

  • 류관희;김기영;류영선;한재성;신태웅
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.277-284
    • /
    • 1998
  • This study was conducted to develop m automatic pot-seedling transplanter for plant factory. The transplanter consists of a gripper, row-spacing control device, nursing tray transfer system, growing trough transfer system, and gripper moving device. The gripper picks up pot-seedling. The gripper moving device moves the gripper between nursing tray and growing-flat. Nursing trays are moved to workspace by the nursing tray transfer system. The growing trough transfer system was developed to move growing trough to workspace. The row-spacing control device was used to adjust the distance between adjacent plants traversely. The results of this study are as follows. The transplanting capacity of the developed transplanter was 7.1 seconds per cycle or 1.18 second per pot-seedling. Successful planting was 98.9% without seedlings and 95.8% with seedlings.

  • PDF

Series tuned mass dampers in train-induced vibration control of railway bridges

  • Kahya, Volkan;Araz, Onur
    • Structural Engineering and Mechanics
    • /
    • v.61 no.4
    • /
    • pp.453-461
    • /
    • 2017
  • This paper presents the series multiple tuned mass dampers (STMDs) to suppress the resonant vibrations of railway bridges under the passage of high-speed trains (HSTs). A STMD device consisting of two spring-mass-damper units connected each other in series is installed on the bridge. In solution, bridge is modeled as a simply-supported Euler-Bernoulli beam with constant cross-section, and vehicle is simulated as a series of moving forces with constant speed. By the assumed mode method, the governing equations of motion of the beam-TMD device coupled system traversed by a moving train are obtained. The optimum values for the parameters of the STMD device are obtained for the criterion based on the minimization of the maximum dynamic displacement of the beam at its midspan. Single TMD and multiple TMDs in parallel are also considered for demonstration of the STMD device's performance. The results show that STMDs are effective in bridge vibration suppression and robust to parameters' change in the main system and the absorber itself.

A development of double-moving system for composite die using multi-axis shuttle unit in the sheet metal forming (판재성형 가공에서의 다축 단동 유닛을 이용한 복합금형용 Double-moving System 개발)

  • Kim, Dong-wook;Choi, Kyu-Kwang
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.39-43
    • /
    • 2016
  • Most of automobile parts manufactured through sheet metal forming are mass-produced by using press mold. In recent years, automation and speeding up of press lines have been expanding to maximize product productivity using a press die. The proportion of the moving time in the press line is high, and therefore requires high-speed and automated equipment for the moving process. In this paper, to provide the double-moving system can be the moving time reduction and increased productivity. Developed transport system consists of the material supply, the material feeding device and the PLC controller and the devices are positioned between each of the pressing process. In this paper, the double-moving system including developed units using a multi-axial single-acting through this reduced the C/T(cycle time) and improved the productivity.

Dose perturbation measurements during the liver treatment with internal organ motion: Mathematical modeling and Experimental simulation (호흡에 의한 내부 움직임의 영향이 있는 간에서의 실험적 선량 측정)

  • Chung, Jin-Bum;Kim, Yon-Lae;Chung, Won-Kyun;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.115-118
    • /
    • 2004
  • Respiratory motion in the thorax and abdomen is an important limiting factor in high-precision radiation therapy. The lung tumor and tumor(pancreas, stomach) in abdomen therefore are internal motion due to breathing. We will perform to measurement of dose distributions for these moving tumors. In preliminary study, we investigated displacement of moving tumor such as liver, lung tumor in abdomen with previously reported papers. With reference data, internal movements of tumor are displayed with phantom and moving control device(MCD), which appear three dimension (3-D) motion such as x, y and z axis. These devices are used to access dose delivered in tumor with and without internal motion. The MCD and phantom were used to evaluate a delivered dose under similar condition, although there are not same internal tumor motion. In future, we will obtain the exact evaluation of dose if improved in programed software of moving control device and measure precise internal motion using image modality such as fluoroscopy, simulator in based on this study.

  • PDF

About the Necessity for Development of Autonomous Mobility Device for Children with Severe Developmental Retardation

  • Matsuo, Kiyomi;Murata, Tomoyuki;Koga, Takanori;Kubo, Atsuko;Yoshida, Yuichi;Karakawa, Yosuke;Kawaguchi, Hiroshi;Tanaka, Toru;Masaki, Jun;Taketomi, Toshikatsu;Kitajima, Takeo
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.1-4
    • /
    • 2009
  • In this paper, I will report the cases of children who are able to study at kindergarten or elementary school because they learned how to move by themselves using a moving aid before school age, and I will also discuss the development of a mobility device which allows severely disabled preschoolers to practice moving around by themselves safely and easily at home and institutions.

  • PDF