• Title/Summary/Keyword: Movement evaluation

Search Result 1,111, Processing Time 0.03 seconds

Extra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motion

  • Lee, Hyun Su;Choi, Chansoo;Kim, Chan Hyeong;Han, Min Cheol;Yeom, Yeon Soo;Nguyen, Thang Tat;Kim, Seonghoon;Choi, Sang Hyoun;Lee, Soon Sung;Kim, Jina;Hwang, JinHo;Kang, Youngnam
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.103-109
    • /
    • 2019
  • Background: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.

Applying the Metaverse Platform and Contents in Practical Engineering Education (공학교육 현장에서의 메타버스 플랫폼 및 콘텐츠 활용)

  • Lee, Yongsun;Lee, Taekhee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.31-43
    • /
    • 2022
  • Recently, metaverse is rapidly expanding its area as a platform that can be applied to various fields. In particular, the function that allows many users to interact in a three-dimensional space allows VR/AR-based educational content to be used as a more advanced concept. Due to the nature of engineering education, it is often based on three-dimensional objects. In the case of a three-dimensional object, it is difficult to explain through two-dimensional videos or documents, and it becomes more difficult to express when the process of changing the object is included. The three-dimensional space of the metaverse can improve this difficulty based on real-time rendering. Another characteristic of engineering education is that there are many invisible elements. Although it is involved in the movement of objects due to electromagnetic fields, magnetic fields, and forces, it is the main reason for increasing learning difficulty because it is invisible. These problems can also help learning because they can be visually represented in the metaverse space. In this paper, the results of the establishment of the metaverse platform for engineering education and the real-time lecture contents produced based on it are described, and the applied results and lecture evaluation are discussed. Lectures using a total of 9 metaverse contents were conducted, and 90% of the positive lecture evaluation results were obtained.

Research on optimal safety ship-route based on artificial intelligence analysis using marine environment prediction (해양환경 예측정보를 활용한 인공지능 분석 기반의 최적 안전항로 연구)

  • Dae-yaoung Eeom;Bang-hee Lee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.05a
    • /
    • pp.100-103
    • /
    • 2023
  • Recently, development of maritime autonomoust surface ships and eco-friendly ships, production and evaluation research considering various marine environments is needed in the field of optimal routes as the demand for accurate and detailed real-time marine environment prediction information expands. An algorithm that can calculate the optimal route while reducing the risk of the marine environment and uncertainty in energy consumption in smart ships was developed in 2 stages. In the first stage, a profile was created by combining marine environmental information with ship location and status information within the Automatic Ship Identification System(AIS). In the second stage, a model was developed that could define the marine environment energy map using the configured profile results, A regression equation was generated by applying Random Forest among machine learning techniques to reflect about 600,000 data. The Random Forest coefficient of determination (R2) was 0.89, showing very high reliability. The Dijikstra shortest path algorithm was applied to the marine environment prediction at June 1 to 3, 2021, and to calculate the optimal safety route and express it on the map. The route calculated by the random forest regression model was streamlined, and the route was derived considering the state of the marine environment prediction information. The concept of route calculation based on real-time marine environment prediction information in this study is expected to be able to calculate a realistic and safe route that reflects the movement tendency of ships, and to be expanded to a range of economic, safety, and eco-friendliness evaluation models in the future.

  • PDF

Evaluation of Data-based Expansion Joint-gap for Digital Maintenance (디지털 유지관리를 위한 데이터 기반 교량 신축이음 유간 평가 )

  • Jongho Park;Yooseong Shin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.1-8
    • /
    • 2024
  • The expansion joint is installed to offset the expansion of the superstructure and must ensure sufficient gap during its service life. In detailed guideline of safety inspection and precise safety diagnosis for bridge, damage due to lack or excessive gap is specified, but there are insufficient standards for determining the abnormal behavior of superstructures. In this study, a data-based maintenance was proposed by continuously monitoring the expansion-gap data of the same expansion joint. A total of 2,756 data were collected from 689 expansion joint, taking into account the effects of season. We have developed a method to evaluate changes in the expansion joint-gap that can analyze the thermal movement through four or more data at the same location, and classified the factors that affect the superstructure behavior and analyze the influence of each factor through deep learning and explainable artificial intelligence(AI). Abnormal behavior of the superstructure was classified into narrowing and functional failure through the expansion joint-gap evaluation graph. The influence factor analysis using deep learning and explainable AI is considered to be reliable because the results can be explained by the existing expansion gap calculation formula and bridge design.

Evaluation and Management of Frailty, and Its Association With Pain (노쇠의 평가와 관리, 그리고 통증과의 연관성)

  • Kang Joon Lee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • Frailty is a clinical syndrome as an increased vulnerability to stressors, leading to a decrease in physiologic reserves and a decline in the ability to maintain a good homeostasis. This condition leads to an increased risk of hospitalization, disability and mortality. Frailty occurs due to various causes and requires a multidimensional approach. It is also important to detect and manage it early. Frailty is also deeply related to neuropsychiatric problems such as pain and depression. In evaluating frailty, it is desirable to comprehensively consider not only physical areas such as disease, nutrition, movement, and sensory functions, but also psychosocial areas, and representative scales include Fried's physical frailty phenotype and Rockwood's frailty index. Physical activity and appropriate protein intake are important for frailty management, and inappropriate drug use should be reduced and oral care, cognitive function, and falls should also be noted. Frailty and pain can affect each other, and pain can promote frailty. Evidence has been published that hormone and protein abnormalities, immune system activity and inflammatory response, and epigenetic mechanisms work in common in the field of frailty and pain. More extensive and high-quality research should be conducted in the future, and the quality of life will be improved if the results are applied to the suppression and treatment of old age and pain.

Performance Evaluation of Smartphone Camera App with Multi-Focus Shooting and Focus Post-processing Functions (다초점 촬영과 초점후처리 기능을 가진 스마트폰 카메라 앱의 성능평가)

  • Chae-Won Park;Kyung-Mi Kim;Song-Yeon Yoo;Yu-Jin Kim;Kitae Hwang;In-Hwang Jung;Jae-Moon Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.2
    • /
    • pp.35-40
    • /
    • 2024
  • In this paper, we validate the practicality of the OnePIC app implemented in the previous study by analyzing the execution and storage performance. The OnePIC app is a camera app that allows you to get a photo with a desired focus after taking photos focused on various places. To evaluate performance, we analyzed distance focus shooting time and object focus shooting time in detail. The performance evaluation was measured on actual smartphone. Distance focus shooting time for 5 photos was around 0.84 seconds, the object detection time was around 0.19 seconds regardless of the number of objects and object focus shooting time for 5 photos was around 4.84 seconds. When we compared the size of a single All-in-JPEG file that stores multi-focus photos to the size of the JPEG files stored individually, there was no significant benefit in storage space because the All-in-JPEG file size was subtly reduced. However, All-in-JPEG has the great advantage of managing multi-focus photos. Finally, we conclude that the OnePIC app is practical in terms of shooting time, photo storage size, and management.

Assessment of External Radiation Dose for Workers in Domestic Water Treatment Facility According to the Working Type (국내 수처리시설 종사자 작업유형에 따른 외부피폭방사선량 평가)

  • Seong Hun Jeon;Seong Yeon Lee;Hyeok Jae Kim;Min Seong Kim;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.151-160
    • /
    • 2023
  • The International Atomic Energy Agency (IAEA) proposes 11 industries that handle Naturally Occurring Radioactive Material (NORM) that are considered to need management. A water treatment facility is one of the above industries that takes in groundwater and produces drinking water through a water treatment process. Groundwater can accumulate natural radionuclides such as uranium and thorium in raw water by contacting rocks or soil containing natural radionuclides. Therefore, there is a possibility that workers in water treatment facilities will be exposed due to the accumulation of natural radionuclides in the water treatment process. The goal of this study is to evaluate the external radiation dose according to the working type of workers in water treatment facilities. In order to achieve the above goal, the study was conducted by dividing it into 1) analysis of the exposure environment, 2) measurement of the external radiation dose rate 3) evaluation of the external radiation dose. In the stage of analyzing the exposure environment, major processes that are expected to occur significantly were derived. In the measurement stage of the external radiation dose rate, a map of the external radiation dose rate was prepared by measuring the spatial radiation dose rate in major processes. Through this, detailed measurement points were selected considering the movement of workers. In the external radiation dose evaluation stage, the external radiation dose was evaluated based on the previously derived external radiation dose rate and working time. As a result of measuring the external radiation dose rate at the detailed points of water treatment facilities A to C, it was 1.90×10-1 to 3.75×100 μSv h-1, and the external radiation dose was analyzed as 3.27×10-3 to 9.85×10-2 mSv y-1. The maximum external radiation dose appeared during the disinfection and cleaning of activated carbon at facility B, and it is judged that natural radionuclides were concentrated in activated carbon. It was found that the external radiation dose of workers in the water treatment facility was less than 1mSv y-1, which is about 10% of the dose limit for the public. As a result of this study, it was found that the radiological effect of external radiation dose of domestic water treatment facility workers was insignificant. The results are expected to contribute as background data to present optimized safety management measures for domestic NORM industries in the future.

The Effect of Spiral Balance Taping on Postoperative Sequelae in Breast Cancer : Case study (스파이랄 발란스 테이핑이 유방암 환자의 수술 후 후유증에 미치는 영향 : 사례연구)

  • Su-Ji Kang;Dae-Hee Lee;Cheul Jang;Back-Vin Lim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose : Cancer survivors often suffer from postoperative sequelae. the diagnosing and provision of manual therapy using spiral taping significantly improves the quality of life of cancer patients. The aim of this case study is to investigate the immediate effects of spiral taping on pain, range of motion (ROM), chemotherapy-induced peripheral neuropathy (CIPN), and lymphedema following breast cancer surgery. Methods : The taping techniques were performed as follows by spiral taping. The measurements were taken before, in the middle, and after taping using a mobile phone camera, tape measure, and a numerical rating score (NRS). The evaluation employed a single-group pre-post design based on a primitive experimental design. Results : Out of four patients, all four exhibited Reverse circle flow energy (RCFE), Passive cervical right (Rt) rotation test, anterior-posterior movement pattern, nerve type (+), cold energy (CE), sangcho acupuncture point, blood clot, hwal point. Comparing before and after treatment, almost all values were reduced to zero after treatment in terms of pain complaints. The lack of range of motion (ROM) caused by the shortened tissue after surgery did not increase. The range of motion (ROM) lost due to pain returned to normal. The circumference of lymphedema did not show a tendency. The symptoms of CIPN improved. Conclusion : There was a significant change in joint range of motion, with pain decreasing, but there were structural limitations in the tissue due to total resection, and the chemotherapy-induced peripheral neuropathy scale. It was effectively treated surgical site pain, axillary membrane syndrome-induced pain, and unexplained pain. While there was a treatment effect for lymphedema in the evaluation of circumference values, there was no significant change in circumference. There was a significant effect on chemotherapy-induced peripheral neuropathy, particularly in treating numbness in the feet, which is a side effect of TC anticancer drugs. This case study found that spiral balance taping provides a rapid therapeutic effect for most side effects in patients who have undergone total breast cancer resection. However, the generalization is limited due to the small sample size, and further research is needed to determine the extent to which the effects of one treatment are maintained.

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

Application Strategies of Eye-tracking Method in Nightscape Evaluation (야간경관 평가에서의 아이트래킹 분석 적용 연구)

  • Kang, Youngeun;Kim, Mintai
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.87-97
    • /
    • 2015
  • There's a trend towards vitalization of nightscape planning businesses nationally and locally as well for city image making and activation of regional economy, but there is still no systematic nightscape planning going on for lack of relevant researches and objective evaluations. This study aims to suggest the guideline for nightscape planning by conducting an eye tracking experiment and survey for recognizing the characteristics of a nightscape. Furthermore, the authors intended to verify the eye-tracking method as a tool for landscape evaluation. The research site was restricted in the campus of Virginia Tech, VA, and those were selected by experts' survey among various types of nightscape images. The variables for analyzing the characteristics of nightscape images selected were 'preference', 'safety(fear)' and 'clearness'. 'Fixation duration', 'saccade duration', 'scan path length', and 'pupil size' were selected as the eye movement measurements. The results of this study are as follows: The first outcome found was that there were significant differences among the characteristics(preference, safety and clearness) of a nightscape by MANOVA, and these variables were correlated positively by Pearson's correlation. Secondly, there were differences on fixation duration, saccade duration and scan path depending on the nightscape setting statistically. Also, the eye tracking measurement in an open setting was recorded lower than enclosed settings. In the result of a heat map, we found the meaning of the fixated areas on both viewing without intention and viewing intentionally. It turned out that the fixated areas were consistent with the areas the subjects felt preferred and clarity in all of the nightscape images, which means people usually focus on what they prefer and see clearly in a certain nightscape. Based on this result and previous studies, the authors could make a conclusion that eye tracking method can apply to evaluate nightscape settings in terms of analyzing the whole characteristics and finding specific points for the detailed analysis as well. Therefore, these results can contribute by suggesting nightscape planning, implication of the landscape evaluation, and implication of the eye tracking study.