• Title/Summary/Keyword: Motor Loading

Search Result 181, Processing Time 0.025 seconds

Water Lubrication System Supported by High-density Hydrophilic Polymer Brush

  • Kobayashi, Motoyasu;Ishihara, Kazuhiko;Takahara, Atsushi;Suzuki, Atsushi;Kaido, Masataka;Zhe, Wang
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.343-343
    • /
    • 2006
  • Surface-initiated atom transfer radical polymerization of 2-methacryloyloxyethyl phosphorylcholine (MPC) was carried out to produce high-density poly(MPC) brush on silicon wafer. Frictional properties of poly(MPC) was investigated by by sliding a glass ball (${\phi}\;10\;nm$) on the substrates over a distance of 20 mm at a sliding velocity of 90 mm/min under loading of 0.49 N at 298 K. Higher friction coefficients were observed in dry N2 atmosphere and in toluene condition, whereas the friction coefficients decreased to 0.02 in humid air and in water. It is supposed that water-swollen poly(MPC) brush works as a lubricant to moderate the interaction between brush and probe.

  • PDF

A safety evaluation on the loading test of EMU′s carbody having stainless and aluminum (스테인리스와 알루미늄으로 제작된 전동차의 구조체 하중시험에 대한 안전성 평가)

  • 정종덕;김원경;윤성철;편장식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1525-1529
    • /
    • 2003
  • This paper describes the result of carbody load test. The purpose of the test is to evaluate an safety which carbody structure shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load and operating condition. Carbody material applied a stainless steel and an aluminum alloy, The stainless steel model is the carbody of a motor car which is delivering to KNR line 1 in 2002 and the aluminum alloy model is the carbody of a motor car which is delivering to GWANGJU line 1 in 2003.

  • PDF

Variation of electromagnetic noise of 3 phase induction motor between un-loaded and loaded running (3상 유도전동기의 무부하 및 부하 운전시 전자기 소음의 변화)

  • Kwon, B.H.;Ahn, J.R.;Chun, T.W.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.9-11
    • /
    • 2008
  • When a squirrel cage induction motor is loaded, the electromagnetic noise can increase depending on the load current. It is due to the air gap harmonic fluxes from the rotor current induced during loading. This unfavorable noise can be anticipated by calculating the radial force waves in the air gap, vibration mode shapes of them, and stator core natural frequencies of each mode. With the experimental tests with the different rotor slot numbers, the variation of electromagnetic noise is studied between on-loaded and loaded running.

  • PDF

Optimal Design of 100W Class Single Phase Series Commutator Motor (100W급 단상직권 정류자 전동기의 최적설계)

  • Seo, Young-Taek;Lee, Woo-Suk;Gong, Jung-Sik;Oh, Chul-Soo;Bae, Sang-Han
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.720-722
    • /
    • 2000
  • Single phase series commutator motors is widely used in various home appliances, such as vacuum cleaner, electric mixers, electrical tools, etc. This paper deals with the characteristics of single phase series commutator motors of which parameters varied with stator turns and stack length to find optimal electric and magnetic loading. We try to measure these data through the experiments with several prototype motors. The experimental results show some specific stator turns and stack length with which this motor has the highest efficiency.

  • PDF

A safety evaluation on the loading test of EMU′s carbody having stainless and aluminum (도시철도차량의 스테인리스와 알루미늄 구조체 하중시험에 대한 안전성평가)

  • 정종덕;김원경;홍용기;윤성철;이장욱
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.156-161
    • /
    • 2002
  • This paper describes the result of carbody load test. The purpose of the test is to evaluate an safety which carbody structure shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load and operating condition. Carbody material applied a stainless steel and an aluminum alloy, The stainless steel model is the carbody of a motor car which is delivering to KNR line 1 in 2002 and the aluminum alloy model is the carbody of a motor car which is delivering to GWANGJU line 1 in 2003. This strength test is based on "performance test standard for Electrical Multiple Unit, noticed by Ministry of Construction & Transportation, in 2000" and reference code is UIC 566 and JIS E 7105.

  • PDF

Design and Drive Characteristics of Low Voltage 8/6 SRM for Fan Application (팬구동용 저압 8/6 SRM의 설계 및 구동 특성)

  • Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1371-1376
    • /
    • 2014
  • In this paper, 4-phase switched reluctance motor(SRM) with 8-stator and 6-rotor pole structure is proposed for a high speed fan with a low voltage. The air blower has unidirectional rotation characteristics and requires a low torque ripple and noise as well as high efficiency. To achieve the requirements, voltage and current according to loading condition of limited specification is considered. Design process is to select the bore diameter, pole arc, york of stator and rotor to get a high torque and efficiency. To verify the validity of the proposed structure, finite element method(FEM) is employed to get the performances. And the converter for the proposed SRM is employed a 1.5q power converter for cost effectiveness. Prototype SRM is manufactured and tested, and the test results show this design is within the specification and good for the air blower applications.

A Design of Load Shedding System Considering both Angular Stability and Voltage Stability in Industrial Power System (산업용 전력계통의 주파수 안정도와 전압 안정도를 고려한 부하차단 설계)

  • Kim, Bong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.103-109
    • /
    • 2004
  • This paper has presented, taking an example of a gas separation plant, dynamic analysis on frequency decline caused by the over-loading at the generator and the knee point causing voltage instability due to reactive power required by re-acceleration of large induction motors, resulting in phenomena of failure in the conventional frequency load shedding. In order to resolve the voltage instability problem, a design of load shedding system employing under-voltage relays has been proposed to the industrial power system containing large induction motors in addition to the conventional load shedding employing frequency relays. For the purpose of dynamic analysis, models of gas turbine and governor, synchronous generator, brushless exciter, and induction motor are introduced.

Design and Characteristic Analysis of LSM for High Speed Train System using Magnetic Equivalent Circuit

  • Ham, Sang-Hwan;Cho, Su-Yeon;Kang, Dong-Woo;Lee, Hyung-Woo;Chan, Hong-Soon;Lee, Ju
    • International Journal of Railway
    • /
    • v.3 no.1
    • /
    • pp.14-18
    • /
    • 2010
  • This paper describes design and characteristic analysis of long primary type linear synchronous motor (LSM) for high speed train system. LSM is designed using loading distribution method and magnetic equivalent circuit. For characteristic analysis of LSM, analytical and numerical methods are applied. Analytical method for solving the magnetic field distribution of the analytic model is based on the Maxwell’s equations. Using the characteristic equation and magnetic equivalent circuit, we analyze the effect of variation of parameters, and then we validate the result by comparing with numerical method by finite element method (FEM). We compare the analytical method with numerical method for analyzing the effect by variable parameters. This result will be useful of design and forecast of performance without FEM.

  • PDF

Effects of Low Grade Axial Loading on Discogenic Low Back Pain: A Case Report

  • Chang, Duncan;Boby, Arantxa;Madonna, James
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.4
    • /
    • pp.1683-1686
    • /
    • 2018
  • Low back pain (LBP) is the most common reason for seeking physical therapy (PT) care. Recent studies suggest that axial loading can have a positive impact on the intervertebral disc by improving its tensile strength. Further, whole body vibration (WBV) appears to improve spinal muscle relaxation. Therefore, this case study describes the use of axial loading using a mini-trampoline in a female with chronic LBP. This case report is a single subject design. This patient is a 29-year-old female with a six-month history of low back pain following a motor vehicle accident. MRI found herniated discs at L4 and L5, clinical tests were positive for pain in the L4 and L5 dermatome and myotome the slump test was positive for neural tension, and LBP was constant at 4-6/10 over the past four months. She received axial loading exercises using a mini-trampoline and performed six sessions that were, scheduled twice a week for three weeks. Her Oswestry Disability Index (ODI) score improved from 40% at the time of her first visit to 22% at her final visit. Pain measure on the Numeric Pain Rating Scale (NPRS) after the first treatment was 7/10, and her pain after the final treatment was 0/10. These changes in the pain scores are clinically significant and exceed the minimal clinically important difference (MCID). This patient had a significant improvement in her pain using the NPRS and the ODI. This case study suggests that axial loading may be an effective treatment for some individuals with discogenic chronic low back pain.

A study on Development of Actuator for Biped Walking Robot (직립보행로봇 Actuator 개발에 관한 연구)

  • Moon, Jin-Soo;Kim, Cheul-U
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.73-80
    • /
    • 2005
  • Biped robot requires that an energy source and a control part should be installed on the body to realize active system. So, we choose the DC motor having high torque in compact size in this study. In the DC motor serve system, we choose power amplifier with analog configuration, developed the module combined the controller and the driver. We applied this module to robot actuator and studied the response characteristics in an action and a return. Main controller with serve system, loading PIC micro controller, can be load on the robot with light weight.