• 제목/요약/키워드: Motor Acoustic Noise

검색결과 169건 처리시간 0.026초

2상 스테핑 모터 드라이버의 성능개선 (Performance Improvement of Stepping Motor Driver)

  • 김일환;오태석
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.91-97
    • /
    • 2004
  • This paper describes the design of a 2-phase stepping motor driver using CPLD(Complex Programmable Logic Device). The driver IC such as L297(SGS-Thomson Microelectronics), which is mostly used has some difficulties in PWM control because of the switching noise of power MOSFETs. It causes current ripple and acoustic noise. To improve theses characteristics, we proposed a new current control method that the output PWM frequency is almost constant using a digital filter. Also we proposed constant current method for 1-2 phase(half step) excitation. The proposed method is implemented with CPLD(Xilinx, XC9572-PC44). Experimental results show the effectiveness of the proposed method.

  • PDF

랜덤 PWM을 이용한 왕복동식 압축기의 전자기소음 저감 (Electromagnetic Noise Reduction of Reciprocating Compressor using Random PWM)

  • 조관열;양순배;김학원
    • 전력전자학회논문지
    • /
    • 제5권2호
    • /
    • pp.200-207
    • /
    • 2000
  • 근래 에어컨, 냉장고 및 세탁기와 같은 가전 전기제품에도 전력소비의 저감, 저속운전에 의한 소음저감 및 인간에게 보다 안락한 기능을 제공하기 위하여 인버터 시스템의 적용이 증가되고 있다. 그러나 인버터 시스템은 PWM에 의해 불필요하게 발생되는 전자기소음의 저감과 소음의 질에 대한 감성소음의 개선이 요구된다. 본 논문에서는 브러쉬없는 직류전동기로 구동되는 왕복동식 압축기에 대하여 고정 PWM과 랜덤 PWM의 전자기소음 분석을 통하여 인버터 냉장고에 랜덤 PWM을 적용함으로써 전자기소음의 저감 및 감성소음의 개선효과가 있음을 실험을 통하여 검증하였다.

  • PDF

인버터-유도전동기 구동시스템의 소음 저감을 위한 PWM 방식 (A PWM Strategy for Noise Reduction of Inverter-Induction Motor Drive System)

  • 서영민;이주훈;윤인식;박영진;홍순찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.398-402
    • /
    • 1999
  • In PWM inverter fed traction motor drive systems, the switching frequency is restricted and thus the electromagnetic acoustic noise is generated. To reduce such an audible noise, we propose the modified RSF(Randomized Switching Frequency)-PWM method. In the proposed RSF-PWM method, both triangular wave and sawtooth wave are used in one period as carrier waves. Because the proposed method has inherently the same property as sinusoidal PWM method, there is no problem of linearity. To verify the validity of the modified RSF-PWM method, computer simulations are carried out.

  • PDF

2상 여자방식에 의한 SRM의 운전특성에 관한 연구 (Study on Driving Characteristics of SRM by 2-Phase Exictation Method)

  • 문재원;오석규;안진우;황영문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.193-196
    • /
    • 1998
  • A new excitation method of switched reluctance motor drive is described in this paper. This excitation method produces reluctance torque by mutual action between two phases as well as conventional self reluctance torque due to two phase excitation at a time. In other words, the change of self inductance and mutual inductance are used to produce torque. This paper suggests the operational principle, the mechanism of torque product of switched reluctance motor with two phase excitation. The acoustic noise characteristics of two phase excitation method are described against that of conventional excitation method.

  • PDF

자기 공명 영상법에서의 소음 분석에 관한 연구 (Study on Analysis of Acoustic Noise in MRI)

  • 박세혁;정성택;정순철;조장희;문치웅;이정한;신창희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.550-554
    • /
    • 1997
  • Acoustic or sound noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as unctional MRI (fMRI). Our recent observations in MRI or the visual and motor cortex show very different results with sound noise in comparison with the results obtained without sound noise. Although a number of ideas has been suggested in the literature about the possible elimination or reduction of sound noise, progress has been slow due to the basic role of gradient pulsing in MR imaging. Therefore, we report on some typical behavior of sound noise observed from MRI scanners and the analyses of their characteristics. Data are obtained both from a commercial MRI scanner (GE Signa 1.5-T EPI system).

  • PDF

자기감응 액추에이터를 이용한 능동소음제어 (Active Noise Control Using Sensory Actuator)

  • 고병식
    • 대한기계학회논문집A
    • /
    • 제20권5호
    • /
    • pp.1573-1581
    • /
    • 1996
  • This paper present as experimental demonstratio of DSP and a sensory actuator that is used to actively control sound transmission/radiation through a vibrating plate. A plane acoustic wave incident on a clamped, thin circular plate was used as a noise source, and a sensory actuator bounded to the plate was used to control and sense vibration of the plate. The sound transmission reduction problem was tranformed as a structural vibration control problem that actively control the structural vibration modes coupled to acoustic modes. The results show that the first structural vibration mode is controlled with a reduction of 78 percent in the displacement and velocity of the plate. This corresponds to a 13dB reduction in the acoustic response. These experimental results indicate that a sensory actuator bounded to the plate can be employed to attenuate the sound transmitted to radiated from the plate.

외부 유동에 의한 흡차음재 공간내의 소음 예측 (Predicting Noise inside a Trimmed Cavity Due to Exterior Flow)

  • 정찬희;;최의성;조문환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.466-471
    • /
    • 2014
  • The interior vehicle noise due to the exterior aerodynamic field is an important topic in the acoustic design of a car. The air flow detached from the A-pillar and impacting the side windows are of particular interest as they are located close to the driver / passenger and provides a lower insulation index than the trimmed car body parts. This paper presents a numerical analysis method for a simplified vehicle model. The internal air cavity including trim component are included in the simulation. The car body includes the windshield and two side windows. The body is made of aluminum and trimmed with porous layers. The methodology proposed in this paper relies on two steps: the first step involves the computation of the exterior flow and turbulence induced non-linear acoustic field using PowerFlow. The second step consists in the computation of the vibro-acoustic transmission through the window using the finite element vibro-acoustic solver Actran. Additionally in order to validate the numerical process, an experimental set-up has been created based on the simplified vehicle. The vibration of the windshield and windows, the total wind noise level results and the relative contributions of the different windows are then presented and compared to measurements. The influence of the flow yaw angle (different wind orientation) is also assessed.

  • PDF

전동차 외부소음 저감 방안 검토 (Review of the mitigations the exterior noise level of EMU)

  • 박길배;박희준;기호철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.666-671
    • /
    • 2014
  • To reduce the exterior noise level of EMU, there are several ways have been evaluated. The noise sources for the exterior noise level are the traction motor, driving gear and wheel/rail rolling noise. In this article, the ways to mitigate the noise issue for EMU have been investigated and especially the way to protect the noise radiation from the bogie area and wheel/rail rolling noise. The way to evaluate the effect of the side skirt has been reviewed. To install the side skirt, the interface between the side skirt and the carbody and bogie should be examined and the acoustic design of the side skirt will be evaluated.

  • PDF

3온스 물 삼킴검사 이후 정상 노년층의 음질 변화: 음향학적 분석 (Voice quality of normal elderly people after a 3oz water-swallow test: An acoustic analysis)

  • 이솔희;최홍식;최성희;김향희
    • 말소리와 음성과학
    • /
    • 제10권2호
    • /
    • pp.69-76
    • /
    • 2018
  • The elderly are at increased risk of developing dysphagia due to aging and illnesses. The aim of the current study was to analyze, via an acoustic study, the change in the voice quality of normal elderly people after a 3oz water-swallow test. Subjects included a group of 60 normal elderly people (age: $mean{\pm}SD=76.9{\pm}6.66$) and 60 healthy young adults (age: $mean{\pm}SD=25.1{\pm}2.36$). Every participant produced a five-second /a/ phonation pre- and post-swallowing, and the fractioned two-second sections were analyzed using the MDVP (multi dimensional voice program) analysis. The elderly group demonstrated a post-swallowing increase in the following related acoustic parameters: fundamental frequency, fundamental frequency variation, amplitude-variation, and noise in both two-second sections. However, the younger group showed an increase only in frequency related acoustic parameters (i.e., STD ) in the first two-second section. The significant changes in values in the post-swallowing parameters might indicate temporary irregularities in pitch and amplitude along with higher amounts of noise in the voice. The results could be attributed to water residues in the vocal fold and vocal tract, as well as a deterioration of the motor and sensory functions caused by anatomical and physiological changes that result from aging.

A Simplified Modulation Strategy for Three-leg Voltage Source Inverter Fed Unsymmetrical Two-winding Induction Motor

  • Sinthusonthishat, Saliltip;Chuladaycha, Nontawat
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1337-1344
    • /
    • 2013
  • This paper presents a simplified modulation strategy for the three-leg VSI fed two-winding induction motor. The strategy provides independent unbalanced voltage control for the main and auxiliary windings. This make the motor can be reversed rotation through the range of motor speed operation without limitation of voltage boost of the auxiliary winding. To study the advantages of the proposed drive, the experimental results such as voltage stresses, hysteresis band of the currents in locus, and also acoustic noise levels of the three-leg VSI are compared with those of the conventional two-leg topology. The results obviously show that the proposed technique achieves superior performance compared with the traditional scheme in case of dramatic increase of DC bus utilization, effective reduction of harmonic voltages content, and also significant enhancement of motor efficiency.