• Title/Summary/Keyword: Motion-Limiting Devices

Search Result 8, Processing Time 0.026 seconds

Design Methods of the Longitudinal Motion-Limiting Devices in Multi-Span Continuous Bridges (다경간연속교의 교축방향 이동제한장치의 설계방법)

  • 전귀현;이지훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.145-154
    • /
    • 1998
  • The motion-limiting devices can be used for reducing the maximum and residual displacements of the multi-span continuous bridges with inelastic elements such as isolation bearings and plastic hinges formed in piers. For the design of motion-limiting device, the nonlinear time history analysis is required. But the time history analysis is time consuming and very complex. This study suggests the simple design procedure of the motion-limiting devices using the equivalent elastic analysis method and the acceleration-displacement spectrum concept. The suggested design procedure can be used very effectively for determining the location and gap size of the motion-limiting devices.

  • PDF

Seismic Response Characteristics of the Bridges with Motion-Limiting Devices (이동제한장치가 있는 교량의 지진응답특성)

  • 이지훈;전귀현
    • Computational Structural Engineering
    • /
    • v.11 no.4
    • /
    • pp.331-340
    • /
    • 1998
  • 본 연구에서는 이동제한장치가 있는 연속교의 지진응답특성을 고찰하였다. 일점고정연속교에 있어서 이동제한장치는 교각이 탄성거동을 하는 경우 교축방법 수평력 분산기능이 있으며 교각하부에 소성힌지가 발생하거나 내진분리베어링이 있는 경우에는 최대변위 및 비탄성거동에 따른 잔류변위제한에 매우 효과적이다. 상부구조와 이동제한장치의 충돌시 발생하는 충격력은 완충재의 사용으로 상당히 감소시킬 수 있다. 이동제한장치의 설치위치 및 이격거리는 이동제한장치가 설치될 하부구조의 강성 및 강도와 온도변화, 급제동력, 작은 지진발생시 충돌여부, 신축이음장치유간 등을 고려하여 결정되어야 한다.

  • PDF

Dose perturbation measurements during the liver treatment with internal organ motion: Mathematical modeling and Experimental simulation (호흡에 의한 내부 움직임의 영향이 있는 간에서의 실험적 선량 측정)

  • Chung, Jin-Bum;Kim, Yon-Lae;Chung, Won-Kyun;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.115-118
    • /
    • 2004
  • Respiratory motion in the thorax and abdomen is an important limiting factor in high-precision radiation therapy. The lung tumor and tumor(pancreas, stomach) in abdomen therefore are internal motion due to breathing. We will perform to measurement of dose distributions for these moving tumors. In preliminary study, we investigated displacement of moving tumor such as liver, lung tumor in abdomen with previously reported papers. With reference data, internal movements of tumor are displayed with phantom and moving control device(MCD), which appear three dimension (3-D) motion such as x, y and z axis. These devices are used to access dose delivered in tumor with and without internal motion. The MCD and phantom were used to evaluate a delivered dose under similar condition, although there are not same internal tumor motion. In future, we will obtain the exact evaluation of dose if improved in programed software of moving control device and measure precise internal motion using image modality such as fluoroscopy, simulator in based on this study.

  • PDF

Visualization of Electro-osmotic Flow Instability in a T-shape Microchannel (T자형 마이크로 채널 내부 전기삼투 유동의 불안정성 가시화)

  • Han, Su-Dong;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.2
    • /
    • pp.45-50
    • /
    • 2005
  • Electro-osmotic flow (EOF) instability in a microchannel has been experimentally investigated using a micro-PIV system. The micro-PIV system consisting of a two-head Nd:Yag laser and cooled CCD camera was used to measure instantaneous velocity fields and vorticity contours of the EOF instability in a T-shape glass microchannel. The electrokinetic flow instability occurs in the presence of electric conductivity gradients. Charge accumulation at the interface of conductivity gradients leads to electric body forces, driving the coupled flow and electric field into an unstable dynamics. The threshold electric field above which the flow becomes unstable and rapid mixing occurs is about 1000V/cm. As the electric field increases, the flow pattern becomes unstable and vortical motion is enhanced. This kind of instability is a key factor limiting the robust performance of complex electrokinetic bio-analytical devices, but can also be used for rapid mixing and effective flow control fer micro-scale bio-chips.

  • PDF

Analog active valve control design for non-linear semi-active resetable devices

  • Rodgers, Geoffrey W.;Chase, J. Geoffrey;Corman, Sylvain
    • Smart Structures and Systems
    • /
    • v.19 no.5
    • /
    • pp.487-497
    • /
    • 2017
  • Semi-active devices use the building's own motion to produce resistive forces and are thus strictly dissipative and require little power. Devices that independently control the binary open/closed valve state can enable novel device hysteresis loops that were not previously possible. However, some device hysteresis loops cannot be obtained without active analog valve control allowing slower, controlled release of stored energy, and is presents an ongoing limitation in obtaining the full range of possibilities offered by these devices. This in silico study develops a proportional-derivative feedback control law using a validated nonlinear device model to track an ideal diamond-shaped force-displacement response profile using active analog valve control. It is validated by comparison to the ideal shape for both sinusoidal and random seismic input motions. Structural application specific spectral analysis compares the performance for the non-linear, actively controlled case to those obtained with an ideal, linear model to validate that the potential performance will be retained when considering realistic nonlinear behaviour and the designed valve control approach. Results show tracking of the device force-displacement loop to within 3-5% of the desired ideal curve. Valve delay, rather than control law design, is the primary limiting factor, and analysis indicates a ratio of valve delay to structural period must be 1/10 or smaller to ensure adequate tracking, relating valve performance to structural period and overall device performance under control. Overall, the results show that active analog feedback control of energy release in these devices can significantly increase the range of resetable, valve-controlled semi-active device performance and hysteresis loops, in turn increasing their performance envelop and application space.

A Biomechanical Analysis of an Interspinous Distraction Device for Treatment of Lumbar Spinal Stenosis (요추부 협착증 치료를 위한 극돌기 삽입술의 생체역학적 효과 분석)

  • Lee Hui-Sung;Chen Wen Ming;Song Dong-Ryul;Kwon Soon-Young;Lee Kwon-Yong;Lee Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.210-217
    • /
    • 2006
  • Many types of interspinous distraction devices (IDDs) have been recently developed as an alternative surgical treatment to laminectomy and fusion with pedicle screws for the treatment of the lumbar spinal stenosis (LSS). They are intended to keep the lumbar spine in a slightly flexed posture to relieve pain caused by narrowing of the spinal canal and vertebral foramen. However, their biomechanical efficacies are not well known. In this study, we evaluated the kinematic behaviors and changes in intradiscal pressure (IDP) of the porcine lumbar spine implanted with IDD. For kinematics analysis, five porcine lumbar spines (L2-L6) were used and the IDD was inserted at L4-L5. Three markers (${\phi}{\le}0.8mm$) were attached on each vertebra to define a rigid body motion for stereophotogrammetric assessment of the spinal motion in 3-D. A moment of 7.5Nm in flexion-extension, lateral bending, and axial rotation were imparted with a compressive force of 700N. Then, IDD was implanted at L3-L4. IDPs were measured using pressure transducer under compression (700N) and additional extension moment (700N+7.5Nm). In kinematic behaviors, insertion of IDD resulted in statistically significant decrease 42.8% at the implanted level in extension. There were considerable changes in ROM at the adjacent levels, but statistically insignificant. In other motions, there were no significant changes in ROM as well regardless of levels. IDPs at the surgical level (L3-L4) under compression and extension moment decreased by 12.9% and 18.8% respectively after surgery (p<0.05). At the superiorly adjacent levels, IDPs increased by 19.4% and 12.9% under compression and extension, respectively (p<0.05). Corresponding changes at the inferiorly adjacent levels were 29.4% and 6.9%, but they were statistically insignificant (p>0.05). The magnitude of pressure changes due to IDD, both at the operated and adjacent levels, were far less than the previously reported values with conventional fusion techniques. Our experimental results demonstrated the IDDs can be very effective in limiting the extension motion that may cause narrowing of the spinal canal and vertebral foramens while maintaining kinematic behaviors and disc pressures at the adjacent levels.

A frequency tracking semi-active algorithm for control of edgewise vibrations in wind turbine blades

  • Arrigan, John;Huang, Chaojun;Staino, Andrea;Basu, Biswajit;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • v.13 no.2
    • /
    • pp.177-201
    • /
    • 2014
  • With the increased size and flexibility of the tower and blades, structural vibrations are becoming a limiting factor towards the design of even larger and more powerful wind turbines. Research into the use of vibration mitigation devices in the turbine tower has been carried out but the use of dampers in the blades has yet to be investigated in detail. Mitigating vibrations will increase the design life and hence economic viability of the turbine blades and allow for continual operation with decreased downtime. The aim of this paper is to investigate the effectiveness of Semi-Active Tuned Mass Dampers (STMDs) in reducing the edgewise vibrations in the turbine blades. A frequency tracking algorithm based on the Short Time Fourier Transform (STFT) technique is used to tune the damper. A theoretical model has been developed to capture the dynamic behaviour of the blades including the coupling with the tower to accurately model the dynamics of the entire turbine structure. The resulting model consists of time dependent equations of motion and negative damping terms due to the coupling present in the system. The performances of the STMDs based vibration controller have been tested under different loading and operating conditions. Numerical analysis has shown that variation in certain parameters of the system, along with the time varying nature of the system matrices has led to the need for STMDs to allow for real-time tuning to the resonant frequencies of the system.

Ecological Characteristics of Termite(Reticulitermes speratus kyushuensis) for Preservation of Wooden Cultural Heritage (목조문화재의 보존을 위한 한국산 흰개미의 생태적 특성 연구)

  • Lee, Kyu-Shik;Jeong, So-Young
    • Korean Journal of Heritage: History & Science
    • /
    • v.37
    • /
    • pp.327-348
    • /
    • 2004
  • In this study, after analyzing several local climate characteristics of South Korea, I validated distribution, invasion, foraging, underground activities, attack season as ecological characteristics and also temperature, relative humidity, and tree species as preference characteristics of Korean termites (Reticulitermes speratus kyushuensis Morimoto). Especially, southern part of the Korean peninsula is a suitable area for inhabitation and motion of termites holding same ecological characteristic like R. speratus kyushuensis. Busan is a neighboring district at field distribution north limiting temperature of Coptotermes formosanus Shiraki and Chuncheon is a passing area through the Korean Peninsula of field distribution north limiting temperature of Reticulitermes speratus Kolbe. The termite attack of wood devices was about 34.5% for 3 years in the forest of Jongmyo. Although the attack rate of termite increased each year, the detection rate decreased and the missing rate was high by degrees. I confirmed a foraging habits which is a part of termite colony was a role of continuous decomposition and another was a role of new food hunt as experimental results. The foraging termites were found under ground at Jongmyo in Seoul from April to November in the 2001 and the most active period was on July and August. The termite invasion rate of bait station increased in every monitoring. Through the increasing attack rate of bait station during 2nd monitoring (November, 2000) and 3rd monitoring(March, 2001), I confirmed that termites moved into the deep underground in winter, and were working continuously to forage. R. speratus kyushuensis inhabiting at the Korean Peninsula is a species which has food consumption rate with higher temperature. The termite revealed the greatest amount of food(filter paper) at $30^{\circ}C$(90% RH), but showed increasing death rate at over $32^{\circ}C$. Also, survival rate of this termite was 97% at 84% RH($30^{\circ}C$), but killed 100% at 52% RH($30^{\circ}C$) and 70% RH($30^{\circ}C$). For wood feeding, this was observed the preference in a pine tree(Pinus densiflora) above all others. Survival of termites was high(87%) at a pine tree, but low(13.5%) at a paulownia tree(Paulownia coreana). In this study, I presented the biological characteristic of termite(R. speratus kyushuensis Morimoto) and confirmed the deterioration degree of termite on wooden cultural heritage in Korea. Depending on climate and soil temperature, each area in the southern part of the Korea Peninsula, has some different active period and different distribution of R. speratus kyushensis. With these results, I expect that this report helps to prepare the integrated pest management(IPM) of the termite on wooden cultural heritage in Korea, and it may help to reduce the economical loss from termite damage in Korea.