• 제목/요약/키워드: Motion measurement

검색결과 1,251건 처리시간 0.027초

컴퓨터 정액자동분석에 의한 동결융해 한우 정액의 운동특성 연구 (Motional kinematics of Frozen-thawed Korean native cattle semen use of computer aided semen analysis(CASA) system)

  • 이강남;이병천;김정태;박종임;신태영;황우석
    • 대한수의학회지
    • /
    • 제38권4호
    • /
    • pp.898-908
    • /
    • 1998
  • The aim of this experiments were to assess the time-interval change of motional characteristics in frozen-thawed semen of Korean native cattle (KNC) by using computer aided semen analysis (CASA) technology. Twenty-six KNC frozen semen straws were obtained from Korean KNC improvement department, livestock improvement main division, national livestock cooperatives federation in Korea. Specimens were allowed to thaw at $37^{\circ}C$ for 30 sec in water bath. Semen analysis was performed on semen image analysis system (SIAS, Medical supply, Korea) adjusted to the gate settings and used the semen droplet ($5{\mu}l$) placed on Makler counting chamber (Sefi medical instrument, Israel) prewarmed at $37^{\circ}C$. The same person used the same micropipette to fill the Makler counting chamber. A total of 150 or more of sperms were analysed in each specimen by a single trained person by scanning at least 5 to 10 fields. The measurement parameters in SIAS were as follows ; frame rate = 30 frames per sec, image capture = 1 sec, minimum motile speed = $10{\mu}m/s$, maximum countable sperm number = 400. Statistical analysis was done by Student t-test with use of the Sigma plot program on a IBM personal computer. The dancemean(DNM) and hyperactivated sperm(HYP) of frozen-thawed KNC semen kinematics were significantly decreased(p < 0.05) after 10 min of incubation at $37^{\circ}C$ water bath. But, wobble(WOB) of same sample semen was significantly increased(p < 0.05) after 10 min of incubation and significantly decrease(p < 0.05) after 60 min of same incubation. And, after 30 mim of incubation, significantly differences were found most of motion kinematics, motifity(MOT), curvilinear velocity(VCL), straight line velocity(VSL), average path velocity(VAP), amplitude of lateral head displacement(ALH), beat cross frequency(BCF), mean angular displacement(MAD), dance(DNC), on same sample semen. The DNM of KNC semen sample was variable kinematics after 30 min of incubation. Also, the linearity(LIN) and straightness(STR) was significantly decreased(p < 0.05) from 60 min of incubation. In conclusion, the AI within 30 min after thawing of frozen semen can be an effective method for obtaining high fertility rate in KNC reproductive program.

  • PDF

박동 혈액 순환 모의 시스템에서 시간 동기화된 혈압 및 혈액의 초음파 영상 측정 및 주기적 분석 (Time-synchronized measurement and cyclic analysis of ultrasound imaging from blood with blood pressure in the mock pulsatile blood circulation system)

  • 민수홍;김창수;팽동국
    • 한국음향학회지
    • /
    • 제36권5호
    • /
    • pp.361-369
    • /
    • 2017
  • 뇌혈관 질환의 발생 및 진행 기작을 이해하고 그 질환의 조기진단과 진행예측을 위해서는 경동맥 분지에서의 혈류역학 정보가 매우 중요하다. 본 논문에서는 정상인 경동맥 분지 탄성 모형 혈관과 생체 외 돼지혈액을 이용하여 모의박동 혈액 순환 시스템을 구축하여 혈류를 조절하면서 혈관과 혈액의 초음파 영상을 내부 압력과 시간 동기화하여 측정하였다. 박동 펌프의 박동률이 분당 20회, 40회, 60회(r/min)일 때의 초음파 영상의 에코 값, 혈류속도, 혈관 벽의 움직임, 혈압을 펌프의 5주기 동안 평균하여 한 주기의 데이터를 추출하였다. 결과로 박동률이 20 r/min, 40 r/min, 60 r/min일때 수축기 최고 혈류 속도는 각각 20 cm/s, 25 cm/s, 40 cm/s, 혈압 차는 각각 30 mmHg, 70 mmHg, 85 mmHg, 동맥벽은 각각 0.05 mm, 0.15 mm, 0.25 mm로 확장 하였다. 에코의 주기적 변화는 혈류속도와 압력과는 시간 지연이 있었으며 20 r/min에서는 변화량이 최소였다. 이러한 시간 동기화된 인자들의 주기적 변화는 전산혈류역학 실험의 정확한 입력정보와 검증을 위한 중요한 정보이며 경동맥 협착 질환의 발생 및 진행 기작을 밝히는데도 유용한 정보를 제공할 것이다.

정상인의 관상면에서의 관절와상완운동 및 견갑흉곽운동 (Normal Glenohumeral and Scapulothoracic Movement at the Coronal Plane)

  • 이용걸;임창무
    • Clinics in Shoulder and Elbow
    • /
    • 제1권1호
    • /
    • pp.93-99
    • /
    • 1998
  • 상지의 외전에 따른 관절와상완운동 및 견갑흉곽운동은 전체적으로 1.6:1의 비율로 일어나고 있었으며 외전초기에는 주로 관절와상완관절에서 운동이 일어나고 외전후기에는 관절와상완운동보 다도 견갑흉곽운동에서 약간 더 많은 운동이 일어 남을 알 수 있었다. 상지가 외전시 외회전운동은 약 70도정도가 일어나 상당히 많은 양의 외회전이 일어나고 있음을 알 수 있었으며 이 외회전운동은 외전초기에는 완만하게 일어나다 외전후기에 주로 일어나고 있음을 관찰할 수 있었다. 외전하는 동안 상완골두의 상방전위는 90도까지 3mm로 일정하게 일어나다 그 후로는 하방으로 다시전위되어 최대외전에서는 전위의 변화가 거의 없었으며 이 전위는 견봉상완간격의 변화와 밀접한관계가 있음을 알 수 있었다. 그러나 본 연구는 이차원적인 견관절운동에 대한 연구로 이를 참조하여 추후 삼차원적인 입체적 분석 및 다양한 방향에서의 견관절운동에 대한 좀 더 많은 연구와 관심이 필요할 것으로 사료되었다.

  • PDF

생체신호 측정을 위한 기능성 의류의 디자인 연구 -심전도 센싱 의류를 중심으로- (A Study on the Design of Functional Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing-)

  • 조하경;송하영;조현승;구수민;이주현
    • 감성과학
    • /
    • 제13권3호
    • /
    • pp.467-474
    • /
    • 2010
  • 최근 생체 신호 측정을 위한 기능성 의류는 동작 잡음에 의한 노이즈를 최대한 줄여 정확한 생체 신호를 측정 가능케 하는 것의 중요성에 대한 논의가 이루어지고 있다. 이에 본 연구는 영향 요인별 고려 사항을 반 영하여 3-리드(lead)방식의 은사 자수의 직물 전극을 개발하고, '일자형 절개 타입', '십자형절개 타입', '엑스형 절개 타입', '곡선 엑스형 절개 타입'의 총 네 가지 타입의 생체신호 센싱 스마트 의류의 시안을 설계하고 제작하였다. 디자인 시안은 민소매형태의 남성용 티셔츠로 신축성 있는 소재를 사용하여 인체 굴곡을 따라 의복과 전극이 밀착될 수 있도록 하였으며, 트랜스미터를 이용하여 메인 컴퓨터로 데이터가 무선 전송되게 하였다. 각 재모듈화형 의류 타입별 인체 동작에 의한 영향과 정지 및 동작 상태에서의 심전도 센싱 성능을 평가하기 위해 동작에 따른 전극의 변위를 측정하고, 심전도 측정 평가를 실시하여 SNR을 분석하였다. 본 실험 결과를 반영하여 의류 디자인 시안의 수정 및 보완 과정을 거친 후, 최종적으로 '연속-부착형', '삽입-분리형'의 두 가지 타입의 생체신호 센싱 스마트의류 디자인 모형의 모듈화 방안을 제시하였다.

  • PDF

다중빔 음향측심기 수심 정확도 개선 (Improvement of Multi-beam Echo Sounder's Depth Accuracy)

  • 최철웅;김연수;서용철
    • 한국측량학회지
    • /
    • 제23권1호
    • /
    • pp.1-8
    • /
    • 2005
  • 다중빔 음향측심기는 수심의 3∼4배되는 주사 폭으로 넓은 지역을 동시에 측량하므로 자료의 정밀도와 작업효율성이 단빔 음향측심기보다 상대적으로 높다. 그러나 빔의 생성 및 계측 원리가 정교하여 탐사선의 움직임에 영향을 많이 받기 때문에 부가장치의 정확한 조정 작업이 필수적으로 요구된다. 본 연구에서는 다중빔 음향측심기의 정확도 향상을 목적으로 평탄 해저지형에서 빔의 중앙과 ± 45°의 빔각을 이루는 지역의 수심단면을 가시·통계적으로 분서한 결과, 관성센서의 진동과 부가장치의 오정렬에 의한 오차가 발생하여 부가장치에 대한 조정이 필요하였다. 따라서 방진재를 관성센서에 부착하여 선체로부터 받는 진동을 저감시키고, 선체 자세요소와 부가장치의 오프셋 값을 정밀 계측하여 수평자세요소 값으로 변환·정렬시켰다. 그 결과, ±45° 빔각 지역의 수심 정확도는 IHO S44의 1등급 수로측량 수준에서 특등급 수로측량 수준으로 향상되었으며, 오정렬에 의한 중첩구역의 물결무늬 현상도 현저히 감소하였다.

3차원 시각 주의 모델과 이를 이용한 무참조 스테레오스코픽 비디오 화질 측정 방법 (3D Visual Attention Model and its Application to No-reference Stereoscopic Video Quality Assessment)

  • 김동현;손광훈
    • 전자공학회논문지
    • /
    • 제51권4호
    • /
    • pp.110-122
    • /
    • 2014
  • 최근 사용자에게 직접 입체감을 제공하는 3차원 영상기술에 대한 관심이 증대함에 따라 스테레오스코픽 비디오 화질 측정기술개발은 중요한 주제로 많은 연구자에게 관심을 받고 있다. 특히, 스테레오스코픽 비디오 화질 측정에 중요한 역할을 하는 인간시각특성을 고려한 연구가 활발히 진행되지 않고 있어 본 논문에서 스테레오스코픽 비디오를 시청할 때 자극되는 다수의 인간시각특성 요소인 깊이, 움직임, 컬러, 휘도, 대조 등을 고려하여 3차원 시각 주의 모델을 제안한다. 또한, 본 논문에서는 실제 3차원 영상 특정 영역의 화질 열화 정도를 측정하는데 제안된 3차원 시각 주의 모델을 사용하여 무참조 스테레오스코픽 비디오 화질 측정 방법을 제안하였다. 제안 방법을 검증하기 위해 주관평가를 실시하여 기존의 스테레오스코픽 비디오 화질 측정 방법보다 평균 평가점에서 더 높은 연관성을 보였다. 게다가, 3차원 시각 주의 모델을 이용하여 스테레오스코픽 비디오의 관심영역 추출 결과는 공간적, 시간적 요소를 고려하여 추출된 관심영역에 비해 실제 관심영역과 더욱 유사함을 주관적으로 보여 제안 방법의 효율성을 보였다.

근거중심의학에 근거한 퇴행성 슬관절염에 관한 침치료 임상선행연구 (A Pilot Study of Acupuncture Treatment for the Osteoarthritis of the Knee Joint on the EBM(Evidence Basement Medicine))

  • 임정아;이종덕;이상관;이성용;문형철;최선미;정영해;김성철
    • Journal of Acupuncture Research
    • /
    • 제23권1호
    • /
    • pp.187-215
    • /
    • 2006
  • Objectives : To determine whether the pragmatic acupuncture treatment provides more effective pain relief than treatment using the same acupuncture point to the all patients. Methods : We randomly allocated participants to treatment group 1 and 2. The group 1 is the pragmatic treatment group and the group 2 is using the same acupuncture point to the all patients. Primary outcomes were measured by the Western Ontario and McMaster Universities Osteoarthritis index(WOMAC) pain and function scores at 4, 8, and 14 weeks. Secondary outcomes were measured by 100mm VAS(Visual Analog Scale), ROM(Range of Motion) using Goniometer, and pain threshold using pressure algometer. Results : When patients were extension of the knee, they were statistically significant in improvement of the ROM in 14 weeks. Whole body condition and pain rate through VAS measurement were improved significantly in 14 weeks. Also pain score and function score of WOMAC were improved significantly in 14 weeks. We could get difference in pain score of two acupuncture groups significantly in 14 weeks. But we could not get difference in whole score of two acupuncture groups significantly. Local temperature using T.C thermometer was changed significantly in 14 weeks. But we could not get difference in whole score of two acupuncture groups significantly. Excluding above item, DITI, pain threshold, and ROM of the knee flexion were no difference in before and after treatment.

  • PDF

MRI을 이용한 홍삼 내부조직 판별 (Distinction of Internal Tissue of Red Ginseng Using Magnetic Resonance Image)

  • 김천석;정인찬;김세봉
    • Journal of Ginseng Research
    • /
    • 제32권4호
    • /
    • pp.332-336
    • /
    • 2008
  • 홍삼은 외부형태 및 내부조직품질에 의하여 등급이 분류되고, 3등급이하의 홍삼은 본삼으로 판매하지 않는다. 또한 등급에 따라 가격차이가 매우 큼으로 저급홍삼에 고급홍삼이 혼입되면 경제적 손실이 발생하고, 고급 등급의 홍삼에 하위등급의 홍삼이 혼입되면 클레임이 발생된다. 현재 슬${\hat{e}}{\ddot{u}}$을 이용한 육안검사는 검사자에 따라 기준이 통일되기 어렵고, 오차를 일으킬 가능성이 있어 홍삼의 비 파괴내부조직검사의 가능성을 조사하기 위하여 본 연구를 수행하였다. 홍삼시료의 수분함량은 $10{\sim}13%$에서 MR image를 획득 후 절단하여 MR image가 실제 절단면과 일치하는지 비교 관찰하였다. 홍삼 내부조직의 단면을 보기 위하여 동일한 조건의 Spin echo pulse sequence에서 시간, slice thickness, 온도별로 MR image를 얻었다. 홍삼은 수분함량이 낮기 때문에 MR 신호가 매우 미약하여 single point image(SPI) 측정방법으로는 약 30분 이상 시간이 소요되었다. 그러나 spin echo pulse sequence에서 내부조직을 구분할 수 있는 적당한 시간은 TE(Echo Time) 2.23 ms, TR(Repetition Time) 150 ms에서 약 9초 동안 측정으로 내부조직판별이 가능하였다. Slice thickness를 3, 5, 10 mm로 변화를 주어 측정한 결과 10 mm로 하였을 때 9초 이내에 내부조직 판별이 충분히 가능한 image를 얻을 수 있었다. 55로 약 30분간 시료를 가온 후 얻은 image가 상온에서 얻은 것보다 더 선명하였다. 이러한 원인은 온도를 가함으로서 수분의 활성이 높아져 MR 신호가 더 강해지는 것으로 생각된다. 이로서 짧은 시간에 홍삼의 MR Image를 획득하여 내부조직 특성을 비교 관찰할 수 있었다. 이러한 방법은 홍삼의 내부조직 평가에 활용가능성이 있을 것으로 판단된다.

외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술 (Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder)

  • 김승호;하권익;유재철;이용석;이희동
    • Clinics in Shoulder and Elbow
    • /
    • 제6권1호
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

복부생체전기신호를 이용한 운동 분석 시스템 개발 (Development of Exercise Analysis System Using Bioelectric Abdominal Signal)

  • 강경우;민철홍;김태선
    • 전자공학회논문지
    • /
    • 제49권11호
    • /
    • pp.183-190
    • /
    • 2012
  • 기존의 운동량 측정방법들은 가속도 센서나 GPS, 심장박동, 체온측정 등의 정보를 이용하였으나, 각기 측정방식 및 측정환경 등의 제한으로 인해 정확한 신체활동 측정 및 분석에 어려움이 있었다. 이러한 단점을 극복하기 위해 본 논문에서는, 운동 시 발생하는 생체전기신호를 이용하여 유산소운동은 물론 기존에 측정이 어려웠던 근력운동에 대한 분석도 가능한 시스템을 개발하였다. 운동을 분석하기 위해 두개의 전극이 부착된 허리벨트를 착용해 운동 중 복부에서 발생하는 생체전기신호를 기록했고, 측정된 생체전기신호는 각각 상체 움직임 및 근육활동을 대표할 수 있는 주파수 대역으로 분리한 후, 분리된 각 신호의 파워 값과 차분의 파워 값, 그리고 중간주파수 값들을 운동형태 구분을 위한 특징값으로 추출하였다. 일원분산분석과 다중비교 분석의 통계적 검증을 통하여 추출된 특징값들의 유의성을 검증하였고, 또한 SVM분류기를 이용하여 운동의 형태를 구분하였다. 여섯 가지의 세부운동들을 분류하기 위해 두 가지의 분류방법을 적용하였고, 그 결과 유산소운동과 근력운동으로 분류 시 100%, 유산소운동과 근력운동 및 복합운동으로 분류한 경우 92.7%의 구분율을 보이며 운동형태의 분류가 가능하였다. 또한 유산소운동 및 근력운동의 양을 각각 수치화하여 표현 가능하다. 본 시스템은 기존의 유산소운동 기반의 운동량 측정방식대비 추가적으로 근력운동의 분석이 가능해짐에 따라 보다 다양한 활동에 대해서도 분석이 가능하다.