• Title/Summary/Keyword: Motion capture analysis

Search Result 212, Processing Time 0.027 seconds

Impact of Firefighters' Protective Clothing and Equipment on Upper Body Range of Motion (소방용 방화복 및 방화 장비에 따른 상반신 관절 각도의 동작 범위 연구)

  • Kim, Seonyoung;Park, Huiju
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.635-645
    • /
    • 2015
  • This study analyzed the range of motion of upper body in different configurations of firefighters' protective clothing and equipment. The purpose of this study was to understand the influence of firefighters' protective clothing and equipment over upper body motion in order to improve design of firefighters' protective clothing and equipment. 12 firefighters' upper body range of motion was analyzed while performing standing and walking trials in five different garment configurations including turnout ensemble, fire boots and the self-contained breathing apparatus. Analysis of upper body range of motion included spinal joints of L5S1, L4L3, T1C7, and C1Head. During standing trials, garment configurations caused a significant difference in range of motions at joints of L5S1, L4L3, T1C7, and C1Head. Analysis on the mean of range of motions at L5S1 and L4L3, showed that firefighters' waist bent forward significantly to a greater extent while they wore a self-contained breathing apparatus. A significantly increased range of motion was found for T1C7 and C1Head while carrying a self-contained breathing apparatus, which indicated an increase in the extension of the trunk and neck backward to stand upright and look squarely. A significant difference in range of motion was also found for L5S1 and L4L3 during walking trials.

A Two-dimensional Numerical Study of Hummingbird's Flight Mechanisms and Flow Characteristics (벌새의 비행메커니즘과 유동특성에 대한 2차원 수치해석 연구)

  • Lee, Hyun-Do;Kim, Jin-Ho;Kim, Chong-Am
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.729-736
    • /
    • 2009
  • In order to understand flow characteristics and flight mechanism of hummingbird's flapping flight, two-dimensional numerical analysis is carried out on the flapping motion of hummingbird, Selasphorus rufus. Hummingbird's flapping wing motion is realistically modeled from wind tunnel experimental data to perform numerical analysis. Numerical simulation shows that, as freestream velocity changes, wing trajectory is also adjusted and it substantially affects lift and thrust generation mechanism. According to this tendency, flight domain is separated as "low speed" and "high speed" regime, and each flight domain is studied for physical understanding. As a result, the lift generation during downstroke can be explained by the well-known effects, such as leading edge vortex effect, delayed stall, wake capture and so on. In addition, the lift generation during upstroke, the unique character of hummingbird, is also examined by detailed flow analysis. The thrust generation mechanism is investigated by examining the hummingbird's wing bone structure, vortex generation pattern and the resulting pressure gradient.

Immediate Effects of Low-Dye Taping on the Ankle Motion and Ground Reaction Forces in the Pronated Rear-Foot During Gait

  • Kim, Sung-shin;Chung, Jae-yeop
    • Physical Therapy Korea
    • /
    • v.23 no.1
    • /
    • pp.72-79
    • /
    • 2016
  • Background: Increased foot pronation causes biomedchanical changes at the lower limbs, which may result in musculoskeletal injuries at the proximal joints. Pronation rear-foot leads to plantar fasciitis, Achilles tendonitis, and posterior tibial tendonitis pathologically. According to the recent meta-analysis, They showed that therapeutic adhesive taping is more effective than foot orthoses and motion control footwear, low-Dye (LD) taping has become the most popular method used by physiotherapists. Objects: The purpose of this study was to determine the immediate effects of LD taping results in different ankle motion and ground reaction force (GRF) as before and after applied LD taping on pronated rear-foot during gait. Methods: Twenty-four participants were recruited for this study. The gait data were recorded using an 8-camera motion capture system and two force platforms. At first, the experiments were carried out that participants walked barefoot without LD taping. And then they walked both feet was applied LD taping. Results: The ankle inversion minimum was significantly greater after LD taping than before LD taping (p=.04); however, in the GRF, there were no significant differences in the inversion maximum or total motion of the stance phase (p=.33, p=.07), or in the vertical (p=.33), posterior (p=.22), and lateral (p=.14) peak forces. Conclusion: The application of taping to pronation rear-foot assists in increased ankle inversion.

The Examination of Reliability of Lower Limb Joint Angles with Free Software ImageJ

  • Kim, Heung Youl
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.583-595
    • /
    • 2015
  • Objective: The purpose of this study was to determine the reliability of lower limb joint angles computed with the software ImageJ during jumping movements. Background: Kinematics is the study of bodies in motion without regard to the forces or torques that may produce the motion. The most common method for collecting motion data uses an imaging and motion-caption system to record the 2D or 3D coordinates of markers attached to a moving object, followed by manual or automatic digitizing software. Above all, passive optical motion capture systems (e.g. Vicon system) have been regarded as the gold standards for collecting motion data. On the other hand, ImageJ is used widely for an image analysis as free software, and can collect the 2D coordinates of markers. Although much research has been carried out into the utilizations of the ImageJ software, little is known about their reliability. Method: Seven healthy female students participated as the subject in this study. Seventeen reflective markers were attached on the right and left lower limbs to measure two and three-dimensional joint angular motions. Jump performance was recorded by ten-vicon camera systems (250Hz) and one digital video camera (240Hz). The joint angles of the ankle and knee joints were calculated using 2D (ImageJ) and 3D (Vicon-MX) motion data, respectively. Results: Pearson's correlation coefficients between the two methods were calculated, and significance tests were conducted (${\alpha}=1%$). Correlation coefficients between the two were over 0.98. In Vicon-MX and ImageJ, there is no systematic error by examination of the validity using the Bland-Altman method, and all data are in the 95% limits of agreement. Conclusion: In this study, correlation coefficients are generally high, and the regression line is near the identical line. Therefore, it is considered that motion analysis using ImageJ is a useful tool for evaluation of human movements in various research areas. Application: This result can be utilized as a practical tool to analyze human performance in various fields.

The Effect Analysis of Postural Stability on the Inter-Segmental Spine Motion according to Types of Trunk Models in Drop Landing (드롭착지 동작 시 체간모델에 따른 척추분절운동이 자세안정성 해석에 미치는 영향)

  • Yoo, Kyoung-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.375-383
    • /
    • 2014
  • The purpose of this study was to assess the inter-segmental trunk motion during which multi-segmental movements of the spinal column was designed to interpret the effect of segmentation on the total measured spine motion. Also it analyzed the relative motion at three types of the spine models in drop landing. A secondary goal was to determine the intrinsic algorithmic errors of spine motion and the usefulness of such an approach as a tool to assess spinal motions. College students in the soccer team were selected the ten males with no history of spine symptoms or injuries. Each subject was given a fifteen minute adaptation period of drop landing on the 30cm height box. Inter-segmental spine motion were collected Vicon Motion Capture System (250 Hz) and synchronized with GRF data (1000 Hz). The result shows that Model III has a more increased range of motion (ROM) than Model I and Model II. And the Lagrange energy has significant difference of at E3 and E4 (p<.05). This study can be concluded that there are differences in the three models of algorithm during the phase of load absorption. Especially, Model III shows proper spine motion for the inter-segmental joint motion with the interaction effects using the seven segments. Model III shows more proper observed values about dynamic equilibrium than Model I & Model II. The findings have shown that the dynamic stability strategy of Model III toward multi-directional spinal motion supports for better function of the inter-segmental motor-control than the Model I and Model II.

The Effect of Elastic Taping on the Quadriceps Femoris to the Gait Cycle (대퇴사두근에 대한 탄력테이핑 적용이 보행주기에 미치는 효과)

  • Jung, Byeong-Ok;Ma, Sang-Yeol;Park, Jae-Young
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.2
    • /
    • pp.53-60
    • /
    • 2008
  • Background: The purpose of present study was to investigate the effect of quadriceps femoris taping in normal gait using 3D motion capture technique. Method: Twenty healthy volunteers, have no musculoskeletal problems, were recruited as subjects for this study. In experimental group, 10 males (mean age : 23.6${\pm}$.40) and 10 females (mean age : 21.3${\pm}$.36) were included. Methods of therapeutic taping that taping of patellar inferior and medial gliding and quadriceps. To obtain the dynamic data, we captured the motion of subject attached markers without taping during repeated gaits five times or more in 7 m Capture volume of gait analysis center. The result was obtained as a mean value in three times. After taping on quadriceps femoris, the same procedure was carried out. Statistical analyses were performed using statistical software packagess SPSS WIN 12.0(SPSS, Chicago, IL, USA). Differences were tested for statistical significance using paired t-test, independent t-test, chi-squared test for comparisons between the male and female. Results: The date of 20 subjects who carried out the whole experimental course were statistically analyzed. 1. gait velocity was showed that female group had more significantly increased than male group(p<.05). 2. step length was showed that female group had more significantly increased than male group(p<.05). 3. step width was showed that female group had more significantly increased than male group(p<.05). Conclusion: Elastic taping on quadriceps femoris promoted cadence, gait velocity, step length and step width in normal subject group.

  • PDF

Evaluation of Seat Pan Inclination During Sit-to-stand for Development of Elderly Lifting-chair

  • Hong, Jae-Soo;Kim, Jong-Hyun;Chun, Keyoung-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.357-363
    • /
    • 2011
  • Objective: The aim of this study is to set the design direction of the lift chair's tilting seat for development. Background: Great attention has been shown to the development of senior friendly product, because of increasing elderly population rapidly in Korea. Therefore, we need to study on sit-to-stand(STS) motion of elderly systematically for developing lift chair that is one of senior friendly products. Method: In this study, we analyzed joint moment(knee, hip) and muscle activity (Erector spinae, Rectus femoris, Vastus lateralis) on STS motion of elderly(female, 60~70: 7) and young people(female, 20~30: 7) using 3 dimension motion capture camera, force plate, wireless EMG. Results: The results of muscle activity showed a similar trend but the results of joint moment were a lot of differences between the young and the elderly. Conclusion: The results of knee joint moment suggest the angle(10~30deg)-adjustable seat that can be better than to find the optimal seat's angle. Application: The method and results of this study are expected to develop senior friendly product and verification as well as be available to various application.

Muscular Activity Analysis in Lower Limbs from Motion and Visual Information of Luge Simulator based Virtual Reality (가상현실 루지 시뮬레이터의 동작과 영상정보별 인체 근육활성도 분석)

  • Kang, Seung Rok;Kim, Ui Ryung;Kim, Kyung;Bong, Hyuk;Kwon, Tae Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.9
    • /
    • pp.825-831
    • /
    • 2015
  • In this paper, capture motion and visual information from a virtual reality luge simulator to analyze muscular activity in the lower limbs. The Luge Simulator consists of a motion platform with a pneumatic module for weight distribution. We recruited luge athletes and healthy subjects and made real-time surface EMG measurements to estimate the muscular activity in the lower limbs according to the motion protocol of a simulator, and a test was conducted for each subject. The results indicated that the rectus femoris had the highest muscular activity according to the level of the slope and velocity of the luge. The soleus muscle showed a high level of activity during a turn in the luge according to the direction. We found that the development of a virtual reality sports simulator based on physical reaction results could bring positive effects to optimize reality and human cenesthesia.

Analysis of Motion and Pressure for Circular Friction Massage (전문수기마사지 동작 중 원형강찰법에 대한 동작 및 가압력 분석)

  • Kim, Y.H.;Ryu, J.S.;Son, J.S.;Hwang, S.H.;Sohn, R.H.;Cha, I.H.;Song, J.H.;Song, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.487-493
    • /
    • 2010
  • In this study, the circular friction massage technique was performed on the trapezius, the levator scapulae, and the deltoid muscles to collect the information on massage pressures and positions, and thus to utilize it in professional massage system design. Massage motion was measured with the 3-D motion capture system and finger pressures were simultaneously obtained with grip sensors. Massage motions, pressure patterns, and pressure times were different on each muscle, and the motion trajectory was similar to the ellipsoidal shape. The trapezius had higher pressure, longer massage time, and larger impulse than other muscles. These results could be useful to design a massage system based on biomechanical analysis. In order to improve massage effect, it is also strongly recommended that the tip of the system be similar with that of a human thumb in shape and material.

Posture features and emotion predictive models for affective postures recognition (감정 자세 인식을 위한 자세특징과 감정예측 모델)

  • Kim, Jin-Ok
    • Journal of Internet Computing and Services
    • /
    • v.12 no.6
    • /
    • pp.83-94
    • /
    • 2011
  • Main researching issue in affective computing is to give a machine the ability to recognize the emotion of a person and to react it properly. Efforts in that direction have mainly focused on facial and oral cues to get emotions. Postures have been recently considered as well. This paper aims to discriminate emotions posture by identifying and measuring the saliency of posture features that play a role in affective expression. To do so, affective postures from human subjects are first collected using a motion capture system, then emotional features in posture are described with spatial ones. Through standard statistical techniques, we verified that there is a statistically significant correlation between the emotion intended by the acting subjects, and the emotion perceived by the observers. Discriminant Analysis are used to build affective posture predictive models and to measure the saliency of the proposed set of posture features in discriminating between 6 basic emotional states. The evaluation of proposed features and models are performed using a correlation between actor-observer's postures set. Quantitative experimental results show that proposed set of features discriminates well between emotions, and also that built predictive models perform well.