• Title/Summary/Keyword: Motion artifact

Search Result 148, Processing Time 0.022 seconds

The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals

  • Lee, Han-Wook;Lee, Ju-Won;Jung, Won-Geun;Lee, Gun-Ki
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.6
    • /
    • pp.701-706
    • /
    • 2007
  • The measurement accuracy for heart rate or $SpO_2$ using photoplethysmography (PPG) is influenced by how well the noise from motion artifacts and other sources can be removed. Eliminating the motion artifacts is particularly difficult since its frequency band overlaps that of the basic PPG signal. Therefore, we propose the Periodic Moving Average Filter (PMAF) to remove motion artifacts. The PMAF is based on the quasi-periodicity of the PPG signals. After segmenting the PPG signal on periodic boundaries, we average the $m^{th}$ samples of each period. As a result, we remove the motion artifacts well without the deterioration of the characteristic point.

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Correction of Artifacts due to Patient Arm Motion in PET/CT: Scatter-Limit Correction (PET/CT 검사에서 움직임에 의한 인공물의 산란제한보정법 적용 영상 평가)

  • Bahn, Young Kag;Lee, Seung Jae;Kim, Jung Yul;Oh, Sin Hyun;Nam-Koong, Hyuk;Park, Hoon-Hee;Kang, Chun Koo;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.44-48
    • /
    • 2012
  • Purpose : Arm motion can give rise to striking cold artifact on PET/CT. We investigated that evaluation of scatter-limit correction and correct the patient arm motion artifact in Discovery 600 PET/CT. Materials and Methods : To evaluate a radioactivity uptake (Bq/ml) and a standard uptake value (SUV), the scatter limit correction and scatter correction were compared using 1994 NEMA Phantom$^{TM}$ in Discovery 600 PET/CT (GE Healthcare, Mi, We). Arm motion phantom study was involved a central 20 cm diameter cylinder simulating the neck and 2 peripheral 10 cm diameter cylinders simulating arms. The positions of the arms were altered so as to introduce different amounts of misalignment. The evaluation of arm motion phantom study used the radioactivity uptake and SUV in scatter correction and scatter limit correction. Results : The statistical significance of radioactivity uptake and SUV did not show the differences in comparisons of the scatter limit correction and the scatter correction that not show (p<0.05). Radioactivity uptake of the scatter correction was up to 3.1 kBq/ml in the 0.04 kBq/ml. It was approximately 98.7% undervalued in the arm motion phantom study. However, Radioactivity uptake of the scatter limit correction was up to 3.0 kBq/ml in the 2.11 kBq/ml. It was approximately 30% undervalued in arm motion phantom study. SUV of the scatter correction was 1.05 to 0.006 and underestimated about 98%. However, an applying SUV of the scatter limit correction changed the value as 0.67 which is underestimated about 25%. Radioactivity uptake and SUV of the scatter limit correction was increased approximately 60%, or more than the scatter correction. Conclusion : It is considered that if the patient arm motion artifact was occurred the scatter limit correction will be applicable to give an accurate diagnosis.

  • PDF

ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed (침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정)

  • Lim, Y.G.;Kim, K.K.;Park, K.S.;Jeong, D.U.
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF

A study on non-invasive SaO$_2$ measurement algorithm to improve on effect of the motion artifact (동잡음의 영향을 개선한 비관혈식 산소포화도 측정 알고리즘에 대한 연구)

  • 이준하
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2000
  • Pulse oximetry is a non-invasive optical method which measures arterial oxygen saturation with two different wavelength. We can obtain the pulsating component of the arterial blood superimposed on DC level attenuated by venous blood, skin and other nonpulsatile components. This study is based on computing algorithm of oxygen saturation using the integral ratio of pulsatile components. In this algorithm, we used the half cycle of the pulsatile signal rely on arterial contraction. It's period is about 1/4 in 1 cycle. In the result, Our algorithm with 1/4 period of 1 cycle is similar to existing model. Because of removal that A part have low amplitude and possession in long term from calculating, the effect of the motion-artifact is decrease.

  • PDF

Development of a truncation artifact reduction method in stationary inverse-geometry X-ray laminography for non-destructive testing

  • Kim, Burnyoung;Yim, Dobin;Lee, Seungwan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1626-1633
    • /
    • 2021
  • In an industrial field, non-destructive testing (NDT) is commonly used to inspect industrial products. Among NDT methods using radiation sources, X-ray laminography has several advantages, such as high depth resolution and low computational costs. Moreover, an X-ray laminography system with stationary source array and compact detector is able to reduce mechanical motion artifacts and improve inspection efficiency. However, this system, called stationary inverse-geometry X-ray laminography (s-IGXL), causes truncation artifacts in reconstructed images due to limited fields-of-view (FOVs). In this study, we proposed a projection data correction (PDC) method to reduce the truncation artifacts arisen in s-IGXL images, and the performance of the proposed method was evaluated with the different number of focal spots in terms of quantitative accuracy. Comparing with conventional techniques, the PDC method showed superior performance in reducing truncation artifacts and improved the quantitative accuracy of s-IGXL images for all the number of focal spots. In conclusion, the PDC method can improve the accuracy of s-IGXL images and allow precise NDT measurements.

Noise Reduction of PPG Signal During Free Movements Using Adaptive SFLC(Scaled Fourier Linear Combiner) (적응 SFLC(Scaled Fourier Linear Combiner)를 이용한 활동 중의 PPG 신호의 잡음 감소)

  • Kim, Sung-Min;Cha, Eun-Jong;Kim, Deok-Won;Yoo, Jae-Ha;Kim, Dong-Yon;Kim, Soo-Chan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.138-141
    • /
    • 2006
  • Blood flow is one of vital signals related to human physiological information. Photoplethysmograph (PPG) has been used to measure indirectly heart rate, blood oxygen saturation ($SpO_2$), and so on. Because PPG signal is weak and sensitive to motion artifacts, it is very important to continuously obtain stable PPG signal during free movement. In this study, we applied the scaled Fourier linear combiner (SFLC) using both the adaptive filter and FLC to remove effectively the motion artifacts as well as background noise in the real time without additional signal correlated with motion from a accelerometer. The proposed method would be useful to reduce the movement and background noise which are not synchronized with heart rate.

Noble measurement method for color breakup artifact in FPDs

  • Lee, Jong-Seo;Jun, Tae-Jong;Lee, Joo-Young;Han, Jung-Suk;Souk, Jun-H
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.92-97
    • /
    • 2006
  • Motion artifact of Display devices has a huge interest from industries and users recently. Among those artifacts, color break up (CBU) is one of the key degrading characteristic in field sequential type displays. Unfortunately, there are no objective measurement methods for CBU. Here we introduce two different kinds of CBU and its measurement methods. The CBU characteristic of LCD, DLP, and PDP was measured and compared.

  • PDF

Effect of Module Design for a Garment-Type Heart Activity Monitoring Wearable System Based on Non-Contact Type Sensing (비접촉식 심장활동 모니터링 기능 의복형 웨어러블 시스템의 모듈 효과 탐색)

  • Koo, Hye Ran;Lee, Young-Jae;Gi, Sunok;Lee, Seung Pyo;Kim, Kyeng Nam;Kang, Seung Jin;Lee, Jeong-Whan;Lee, Joo Hyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.3
    • /
    • pp.369-378
    • /
    • 2015
  • Various forms of wearable bio-signal monitoring systems have been developed recently. Acquisition of stable bio-signal data for health care purposes needs to be unconscious and continuous without hindrance to the users' daily activities. The garment type is a suitable form of a wearable bio-signal monitoring system; however, motion artifacts caused by body movement degrade the signal quality during the measurement of bio-signals. It is crucial to stabilize the electrode position to reduce motion artifacts generated when in motion. The problems with motion artifacts remain unresolved despite their significant effect on bio-signal monitoring. This research creates a foundation for the design of garment-type wearable systems for everyday use by finding a method to reduce motion artifacts through modular design. Two distinct garment-type wearable systems (tee-shirt with a motion artifact-reducing module (MARM) and tee-shirt without a MARM) were designed to compare the effects of modular design on the measurement of heart activity in terms of electrode position displacement, signal quality index value, and morphological quality. The tee-shirt with MARM showed superior properties and yielded higher quality signals than the tee-shirt without MARM. In addition, the tee-shirt with MARM showed a better repeatability of the heart activity signals. Therefore, a garment design with MARM is an efficient way to acquire stable bio-signals while in motion.

Image Registration for High-Quality Vessel Visualization in Angiography (혈관조영영상에서 고화질 혈관가시화를 위한 영상정합)

  • Hong, Helen;Lee, Ho;Shin, Yeong-Gil
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.201-206
    • /
    • 2003
  • In clinical practice, CT Angiography is a powerful technique for the visualziation of blood flow in arterial vessels throughout the body. However CT Angiography images of blood vessels anywhere in the body may be fuzzy if the patient moves during the exam. In this paper, we propose a novel technique for removing global motion artifacts in the 3D space. The proposed methods are based on the two key ideas as follows. First, the method involves the extraction of a set of feature points by using a 3D edge detection technique based on image gradient of the mask volume where enhanced vessels cannot be expected to appear, Second, the corresponding set of feature points in the contrast volume are determined by correlation-based registration. The proposed method has been successfully applied to pre- and post-contrast CTA brain dataset. Since the registration for motion correction estimates correlation between feature points extracted from skull area in mask and contrast volume, it offers an accelerated technique to accurately visualize blood vessels of the brain.

  • PDF