• Title/Summary/Keyword: Motion artifact

Search Result 150, Processing Time 0.024 seconds

Cancellation of MRI Artifact due to Rotational Motion (회전운동에 기인한 MRI 아티팩트의 제거)

  • 김응규
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.4
    • /
    • pp.411-419
    • /
    • 2004
  • When the imaging object rotates in image plane during MRI scan, its rotation causes phase error and non-uniform sampling to MRI signal. The model of the problem including phase error non-uniform sampling of MRI signal showed that the MRI signals corrupted by rotations about an arbitrary center and the origin in image plane are different in their phases. Therefore the following methods are presented to improve the quality of the MR image which includes the artifact. The first, assuming that the angle of 2-D rotational motion is already known and the position of 2-D rotational center is unknown, an algorithm to correct the artifact which is based on the phase correction is presented. The second, in case of 2-D rotational motion with unknown rotational center and unknown rotational angle, an algorithm is presented to correct the MRI artifact. At this case, the energy of an ideal MR image is minimum outside the boundary of the imaging object to estimate unknown motion parameters and the measured energy increases when the imaging object has an rotation. By using this property, an evaluation function is defined to estimate unknown values of rotational angle at each phase encoding step. Finally, the effectiveness of this presented techniques is shown by using a phantom image with simulated motion and a real image with 2-D translational shift and rotation.

Cancellation of MRI Motion Artifact in Image Plane (촬영단면내의 MRI 체동 아티팩트의 제거)

  • Kim, Eung-Kyeu
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.309-312
    • /
    • 2000
  • In this work, a new algorithm for canceling MRI artifact due to translational motion in image plane is described. In the previous approach, the motions in the x direction and the y direction are estimated simultaneously. By analyzing their features, each x and y directional motion is canceled by different algorithms in two steps. First, it is noticed that the x directional motion corresponds to a shift of the x directional spectrum of the MRI signal. Next, the y directional motion is canceled by using a new constraint condition. This algorithm is shown to be effective by using a phantom image with simulated motion.

  • PDF

Filter Design to Eliminate Motion Artifact of Pulse Oximetery (펄스 옥시메터의 동잡음 제거 필터 설계)

  • 이주원;이종희;강익태;김경하;이건기
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.431-438
    • /
    • 2001
  • Oxygen saturation of blood is defined as ratio of total hemoglobins density to oxyhemoglobins density And the accuracy of pulse oxymeter that measures the oxygen saturation of blood by a noninvasive method is influenced by a measuring environment, breathing and motion of patient. Especially when patient moved his arms and fingers, it is difficult to eliminate motion artifact because the motion artifact signal has features that are overlap or closed at normal signal in frequency domain. We propose the filtering method that construct the filter banks and a matched falter to improve the Problem. When experimented by the proposed method, the ratio regulation of the proposed methods has 4.1% below than an adaptive filter (39.7%) and a moving average filter (11.2%). So. the Proposed method will be able to get a stable ratio of SpO2.

  • PDF

Development of Pneumography Impedance Based Respiration Measurement System Using Kalman Filter (칼만 필터를 이용한 흉곽 임피던스법 기반의 호흡 신호 계측시스템 개발)

  • Nam, Eun-Hye;Choi, Chang-Hyun;Kim, Yong-Joo;Shin, Dong-Ryeol
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.326-332
    • /
    • 2008
  • A respiration measurement system for vital signs was developed. Respiration signals were measured, processed, and analyzed. Four electrodes, attached on the surface of the skin, were used to monitor respiration signals by impedance pneumography. The measured signals were amplified, detrended, filtered, and transferred toan embedded module. The Kalman filter was used to remove motion artifact from the respiration signals. Experiments were conducted at stable condition and walking condition to evaluate the performance of the system. Respiration rates of five males and five females were measured and analyzed at each condition. The referenced respiration signal was determined by temperature of nose surroundings. The results showed that the respiration rates at the walking condition had more motion artifacts than the stable condition. The accuracies of the respiration measurement system with Kalman filter were found as 96% at the stable condition and 95% at the walking condition. The results showed that the Kalman filter was an effective tool to remove the motion artifact from the respiration signal.

Correction of MRI Artifact due to Planar Respiratory Motion (호흡운동에 의한 MRI 아티팩트의 수정)

  • 김응규;김규헌
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1863-1866
    • /
    • 2003
  • In this study, respiratory motion is modeled by a 2-Dimensional linear expanding-shrinking movement. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimated, a reconstruction algorithm based on superposition method was used to removed the MRI artifact. For the purpose of estimating unknown motion parameters, we applied the spectrum shift method to find the respiratory fluctuation function, the x directional expansion coefficient and its center, and also we used the minimum energy method to find the y directional expansion coefficient and its center. The effectiveness of this presented method is shown by Computer simulations.

  • PDF

MRI Artifact Correction due to Respiratory Motion (호흡운동에 따른 MRI 아티팩트 수정)

  • 김응규;김규헌
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.58-61
    • /
    • 2003
  • In this study, a planar respiratory motion is modeled by a 2-D linear expanding-shrinking movement. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimated, a construction algorithm based on superposition method was used to remove the MRI artifact. For the purpose of estimating unknown motion parameters, we used the spectrum shift method to find the respiratory fluctuation function, the x directional expansion coefficient and its center, and we also used the minimum energy method to find the y directional expansion coefficient and its center. Finally the effectiveness of this presented method is shown by computer simulations.

  • PDF

Motion Blur Measurement with a High-Speed Camera

  • Laur, Juergen;Becker, Michael E.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1135-1138
    • /
    • 2007
  • This paper presents motion picture artifacts measured with a high-speed camera. Measurement results of the high-speed camera on moving targets will be evaluated and compared with motion blur data derived from step responses measured on stationary test patterns with a spot-photodetector.

  • PDF

Rigid Motion Detection and Artifact Correction in MRI Imaging

  • 김용권;류승학;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.97-97
    • /
    • 2002
  • 목적: MRI system에서 얻어지는 기초 data는 k-space 즉, 촬영대상의 Fourier Transform된 data이다. MRI를 이용한 단층 영상 촬영에서 촬영도중 촬영대상이 움직일 경우 움직임으로 인해 artifact가 발생하게 된다. 이것은 영상의 질을 떨어뜨림은 물론, 심한 경우에는 영상을 판독하지 못할 정도로 영상의 질에 영향을 미치게 된다. 이 연구에서는 촬영대상의 움직임이 방향성이 한 방향일 경우 그 움직이는 양을 검출하고, 그 결과를 이용하여 움직임으로 인해 생기는 artifact를 보정하는 방법을 제시하고자 한다.

  • PDF

Algorithm for reduction of motion artifact generated in SpO2 measurement (산소포화도(SpO2) 측정시에 발생되는 motion artifact를 reduction하는 algorithm)

  • 한승헌;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.860-863
    • /
    • 2003
  • Pulse oximetry has gained wide spread clinical acceptance in the latter part of the 21st century. The principle of pulse oximetry is based on the red and infrared light absorption features and uses a light emitter with red and infrared LEDs that shines through a reasonably translucent site with good blood flow. There are two methods of sending light through the measuring site : transmission and reflectance. After the transmitted red and infrared signals pass through the measuring site and received at the photodetector, the red/infrared ratio is calculated. But, pulse of oximeters are so sensitive that they may detect pulses when pressure is too low to provide adequate tissue blood flow, that is, SpO2 may decrease due to O2 consumption by the finger of the pulsing but stagnant arterial blood at low pressure or with vasoconstriction. This project has the limitations of pulse oximetry. Therefore, this paper is focused on the resuction of motion artifact that caused by moving when someone measures with SpO2 system.

  • PDF

Effectiveness of a Turbo Direction Change for Reduction of Motion Artifact in Magnetic Resonance Enterography

  • Choi, Kwan-Woo;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.421-424
    • /
    • 2016
  • The purpose of this study is to evaluate an effectiveness of switching turbo direction to improve motion artifacts of small bowels and aorta. From June to October 2015, 60 patients suspected of having Crohn's disease were enrolled. The MR Enterography scans were performed using same protocol other than the turbo direction: with the Z phase encoding (group A) and with Y phase encoding (group B). Qualitative analysis of each group was performed to evaluate the effectiveness of switching turbo direction from Z to Y. As a result, the 5-point Likert scale for paired observers were $2.33{\pm}0.88$ for group A and $3.80{\pm}0.85$ for group B on dynamic contrast enhanced coronal images. In conclusion, group B is proved to be superior to group A and can lessen the motion artifacts derived from phase shifts.