• Title/Summary/Keyword: Motion Study

Search Result 9,788, Processing Time 0.04 seconds

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Repair of Large to Massive Rotator Cuff Tears in the Elderly Patients (65세 이상 고령 환자의 대형 및 광범위 회전근 개 파열에 대한 봉합술)

  • Jung, Hong Jun;Chun, Jae Myeung;Jeon, In-Ho;Kwon, Jun;Ha, Sang-Ho;Yang, Sung Wook;Lee, Ji-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Purpose: The objective of this study is to evaluate the functional outcome and identify prognosis of retear patients in patients aged 65 years or over undergoing surgical repair for a large to massive full-thickness rotator cuff tear. Materials and Methods: From 1995 September to 2010 March, 147 patients aged 65years or over (40 male, 107 female, with an average age of 69.6) undergoing surgical repair for large to massive full thickness rotator cuff tear (large 67 cases, massive 80 cases). For functional evaluation, preoperative and postoperative 1 year range of motion and muscle power checked. For subjective evaluation, American shoulder and elbow surgeons score and Constant score were checked. For anatomical evaluation, 87 patients were checked shoulder MRI at the time of the postoperative 1 year. Results: ASES score improved from to 50.4 to 88.9, Constant score improved from 47.1 to 75.2. Supraspinatus power improved from 51.1% to 80.8%, external rotator muscle power improved from 64.5% to 83.1%. Forward elevation improved from 117.4 degrees to 153 degrees, external rotation improved from 23.6 degrees to 41.8 degrees. Follow up MRI showed re-tear in 23%, all re-tear patients were from massive tear except one patient. All re-tear patients showed improved clinical outcomes, but supraspinatus and external rotator muscle power were not improved. Conclusions: Patients aged 65 years or over undergoing surgical repair for a large to massive full-thickness rotator cuff tear showed successful outcomes over 90 percent. Re-tear patients also showed successful clinical outcomes. In elderly patients with large to massive full thickness rotator cuff tear, aggressive surgical repair leads good clinical outcomes.

Comparison of Clinical Results in Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Autograft and Tibialis Anterior Tendon Allograft (자가 슬괵건과 동종 전경골건을 이용한 전방 십자 인대 재건술의 임상적 결과 비교)

  • Lee, Hee-Young;Choi, Chul-Jun;Choi, Chong-Hyuk
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.109-114
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the clinical results of ACL reconstruction between two groups using hamstring tendon autograft and tibialis anterior tendon allograft. Materials and Methods: Between January 2006 and June 2007, we analyzed 68 cases of ACL reconstruction, 32 cases using hamstring tendon autograft and 36 cases using tibialis anterior tendon allograft, with a minimum follow-up of 24 months. For the clinical evaluation, we evaluated the Lysholm score, anterior laxity by Telos device and KT-2000 arthrometer. Results: The mean diameter of graft were 8.0 mm (7.0~9.0 mm) in autograft group and 9.1 mm (8.0~10.0 mm) in allograft group. In all cases, the range of motion was above 135 degrees. The average side to side difference in Telos stress test decreased from $7.3{\pm}1.0$ mm to $2.4{\pm}1.1$ mm in autograft group and from $7.4{\pm}1.2$ mm to $2.3{\pm}1.3$ mm in allograft group. The average Lysholm knee score improved from $72.6{\pm}3.4$ to $92.3{\pm}3.5$ in autograft group and from $72.3{\pm}3.5$ to $91.6{\pm}3.3$ in allograft group. There was no significant difference between two groups in clinical results. Conclusion: Both hamstring tendon autograft and tibialis anterior tendon allograft groups showed satisfactory clinical results, with no significant difference in outcomes between the groups. We suggest that both hamstring tendon autograft and tibialis anterior tendon allograft will be considered as acceptable graft for anterior cruciate ligament reconstruction.

  • PDF

The Effect of Meniscectomy on Clinical Result After ACL Reconstruction (전방십자인대 재건술에서 반월상 연골 절제술의 영향)

  • Cho, Hyung-Jun;Lee, Jung-Hwan;Bae, Dae-Kyung;Song, Sang-Jun;Yoon, Kyoung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.1
    • /
    • pp.7-12
    • /
    • 2010
  • Purpose: To evaluate the effects of total or subtotal meniscectomy on anterior cruciate ligament reconstruction. Materials and Methods: We reviewed the 455 cases of arthroscopic ACLR (anterior cruciate ligament reconstruction) from February, 2003 to February, 2007 and followed-up more than 1 year. The 93 cases were enrolled. The 45 cases who underwent only ACLR were included and the 48 cases who underwent ACLR with total or subtotal meniscectomy were included in this study except grade 3 or 4 chondral lesion, partial meniscetomy or meniscal repair. We divided the patient into 4 groups which were isolated ACLR group (group I, 45cases), ACLR with lateral meniscectomy group (group II, 10cases), ACLR with medial meniscectomy group (group III, 28cases) and ACLR with both medial and lateral meniscectomy group (group IV, 10cases). The clinical evaluation was done by range of motion (ROM), IKDC subjective score, Lysholm score, anterior drawer test, Lachman test, Pivot shift test and KT-1000 arthrometer. Results: At final follow up, group IV was inferior than group I in IKDC subjective score and Lysholm score, and inferior than group II in IKDC subjective score. In KT-1000 arhtometric test, group I had better results than group III and group IV. Also in anterior drawer test and Lachman test, group 1 had better result than group III and group IV. In pivot shift test, there was no significant difference among four groups. Conclusion: Medial or both medial and lateral meniscectomy had greater laxity in anterior drawer test, Lachman test and KT-1000 arthrometric test and both medial and lateral meniscectomy had a lower subjective score than both meniscus intact group.

  • PDF

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

A Control Method for designing Object Interactions in 3D Game (3차원 게임에서 객체들의 상호 작용을 디자인하기 위한 제어 기법)

  • 김기현;김상욱
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.3
    • /
    • pp.322-331
    • /
    • 2003
  • As the complexity of a 3D game is increased by various factors of the game scenario, it has a problem for controlling the interrelation of the game objects. Therefore, a game system has a necessity of the coordination of the responses of the game objects. Also, it is necessary to control the behaviors of animations of the game objects in terms of the game scenario. To produce realistic game simulations, a system has to include a structure for designing the interactions among the game objects. This paper presents a method that designs the dynamic control mechanism for the interaction of the game objects in the game scenario. For the method, we suggest a game agent system as a framework that is based on intelligent agents who can make decisions using specific rules. Game agent systems are used in order to manage environment data, to simulate the game objects, to control interactions among game objects, and to support visual authoring interface that ran define a various interrelations of the game objects. These techniques can process the autonomy level of the game objects and the associated collision avoidance method, etc. Also, it is possible to make the coherent decision-making ability of the game objects about a change of the scene. In this paper, the rule-based behavior control was designed to guide the simulation of the game objects. The rules are pre-defined by the user using visual interface for designing their interaction. The Agent State Decision Network, which is composed of the visual elements, is able to pass the information and infers the current state of the game objects. All of such methods can monitor and check a variation of motion state between game objects in real time. Finally, we present a validation of the control method together with a simple case-study example. In this paper, we design and implement the supervised classification systems for high resolution satellite images. The systems support various interfaces and statistical data of training samples so that we can select the most effective training data. In addition, the efficient extension of new classification algorithms and satellite image formats are applied easily through the modularized systems. The classifiers are considered the characteristics of spectral bands from the selected training data. They provide various supervised classification algorithms which include Parallelepiped, Minimum distance, Mahalanobis distance, Maximum likelihood and Fuzzy theory. We used IKONOS images for the input and verified the systems for the classification of high resolution satellite images.

Ultrasound-Guided Local Steroid Injection Therapy for Acute Calcific Tendinitis of Shoulder (초음파를 이용한 급성 극상근 석회화 건염의 스테로이드 국소 주사 요법)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Kang, Min-Ku
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.85-89
    • /
    • 2009
  • Purpose: To analyze the clinical outcome after ultrasound guided multiple dry needlings and local steroid injection for acute calcific tendinitis of shoulder. Materials and Methods: Twenty patients with acute episode of pain by calcific tendinitis of shoulder with average age 58.2 (50~70 years) and follow-up of 18 months in average (range, 12~24) were included in study. There were 18 patients with right and 2 with left sided involvement. All patients had calcific deposits in the supraspinatus tendon. All patients underwent standardized nonoperative treatment protocol, consisting of 5~12 MHz high resolution ultrasound guided multiple dry needlings with 18 guage needle, followed by 2% lidocaine 1cc and 40 mg/ml depomedrol 1cc injection at site of calcific tendinitis. The outcome was assessed by UCLA shoulder score, range of motion and VAS score. A statistical analysis with ANOVA and Tukey's post-hoc test with the significance level at 5% was performed using SAS 9.1 software (SAS Institute, Cary, NC). Results: All patients got continuous relief of pain right after the procedures until final follow-up. Before the procedures, the UCLA scores were fair in 15 patients and poor in 5. After the procedures, the UCLA scores were excellent in 16 patients and good in 4. All cases revealed no limitation of shoulder function. The average VAS score decreased from 8.9 before the procedures to 0.5 at final follow-up (p<0.0001). No complication was encountered. Conclusion: An ultrasound guided local steroid injections following multiple dry needlings would be one of the useful treatment modality for the acute calcific tendinitis of shoulder.

  • PDF

The Follow-up Results of Anterior Cruciate Ligament Reconstruction Using The Flexible Reamer (유연성 연마기를 이용한 관절경적 전방 십자 인대 재건술의 추시 결과)

  • Chae, In-Jung;Wang, Joon-Ho;Choi, Gi-Won;Song, Dong-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.18-23
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the clinical results of the function and stability of ACL reconstruction using the flexible reamer. Materials and Methods: We reviewed 98 patients who taken ACL reconstruction using the flexible reamer from March, 1999 to May, 2004. And the follow-up period was more than 12 months in all cases. We used the subjective tests including Lysholm knee score and 2000 International Knee Documentation Committee(IKDC) subjective knee score, and the objective tests such as anterior drawer test, Lachman test, pivot shift test, and KT-2000 arthrometer to evaluate the clinical results. Results: In the range of motion of the affected knee, the extension deficit more than 5 degree was 8 cases preoperatively and 1 case postoperatively. The flexion deficit more than 5 degree was 12 cases preoperatively and 2 cases postoperatively. The mean Lysholm knee score was 61.3 point(${\pm}3.5$ SD) preoperatively and 87.7 point(${\pm}2.0$ SD) postoperatively. The mean 2000 International Knee Documentation Committee(IKDC) subjective knee score was 49 point(${\pm}3.3$ SD) preoperatively and 84 point (${\pm}2.2$ SD) postoperatively. 93 cases were more than grade II in Lachman test preoperatively and 5 cases postoperatively. 71 cases were more than grade II in pivot shift test preoperatively but 89 cases were negative postoperatively. The mean maximal manual difference by KT-2000 arthrometer was 6.8 mm(${\pm}1.9$ SD) preoperatively and 1.8 mm(${\pm}0.8$ SD) postoperatively. Conclusion: ACL reconstruction using the flexible reamer achieved the ideal isometric point of femur and anatomic graft placement, so we could obtain good results, especially in rotational stability.

  • PDF

Dosimetric Evaluation of Amplitude-based Respiratory Gating for Delivery of Volumetric Modulated Arc Therapy (진폭 기반 호흡연동 체적변조회전방사선치료의 선량학적 평가)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Park, Jeong Hoon;Min, Chul Kee;Shin, Dong Oh;Choi, Sang Hyoun;Park, Seungwoo;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.127-136
    • /
    • 2015
  • The purpose of this study is to perform a dosimetric evaluation of amplitude-based respiratory gating for the delivery of volumetric modulated arc therapy (VMAT). We selected two types of breathing patterns, subjectively among patients with respiratory-gated treatment log files. For patients that showed consistent breathing patterns (CBP) relative to the 4D CT respiration patterns, the variability of the breath-holding position during treatment was observed within the thresholds. However, patients with inconsistent breathing patterns (IBP) show differences relative to those with CBP. The relative isodose distribution was evaluated using an EBT3 film by comparing gated delivery to static delivery, and an absolute dose measurement was performed with a $0.6cm^3$ Farmer-type ion chamber. The passing rate percentages under the 3%/3 mm gamma analysis for Patients 1, 2 and 3 were respectively 93.18%, 91.16%, and 95.46% for CBP, and 66.77%, 48.79%, and 40.36% for IBP. Under the more stringent criteria of 2%/2 mm, passing rates for Patients 1, 2 and 3 were respectively 73.05%, 67.14%, and 86.85% for CBP, and 46.53%, 32.73%, and 36.51% for IBP. The ion chamber measurements were within 3.5%, on average, of those calculated by the TPS and within 2.0%, on average, when compared to the static-point dose measurements for all cases of CBP. Inconsistent breathing patterns between 4D CT simulation and treatment may cause considerable dosimetric differences. Therefore, patient training is important to maintain consistent breathing amplitude during CT scan acquisition and treatment delivery.