• 제목/요약/키워드: Motion Artifacts

검색결과 178건 처리시간 0.024초

Real-Time Heart Rate Monitoring System based on Ring-Type Pulse Oximeter Sensor

  • Park, Seung-Min;Kim, Jun-Yeup;Ko, Kwang-Eun;Jang, In-Hun;Sim, Kwee-Bo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.376-384
    • /
    • 2013
  • With the continuous aging of the populations in developed countries, the medical requirements of the aged are expected to increase. In this paper, a ring-type pulse oximeter finger sensor and a 24-hour ambulatory heart rate monitoring system for the aged are presented. We also demonstrate the feasibility of extracting accurate heart rate variability measurements from photoelectric plethysmography signals gathered using a ring-type pulse oximeter sensor attached to the finger. We designed the heart rate sensor using a CPU with built-in ZigBee stack for simplicity and low power consumption. We also analyzed the various distorted signals caused by motion artifacts using a FFT, and designed an algorithm using a least squares estimator to calibrate the signals for better accuracy.

A Robust Wearable u-Healthcare Platform in Wireless Sensor Network

  • Lee, Seung-Chul;Chung, Wan-Young
    • Journal of Communications and Networks
    • /
    • 제16권4호
    • /
    • pp.465-474
    • /
    • 2014
  • Wireless sensor network (WSN) is considered to be one of the most important research fields for ubiquitous healthcare (u-healthcare) applications. Healthcare systems combined with WSNs have only been introduced by several pioneering researchers. However, most researchers collect physiological data from medical nodes located at static locations and transmit them within a limited communication range between a base station and the medical nodes. In these healthcare systems, the network link can be easily broken owing to the movement of the object nodes. To overcome this issue, in this study, the fast link exchange minimum cost forwarding (FLE-MCF) routing protocol is proposed. This protocol allows real-time multi-hop communication in a healthcare system based on WSN. The protocol is designed for a multi-hop sensor network to rapidly restore the network link when it is broken. The performance of the proposed FLE-MCF protocol is compared with that of a modified minimum cost forwarding (MMCF) protocol. The FLE-MCF protocol shows a good packet delivery rate from/to a fast moving object in a WSN. The designed wearable platform utilizes an adaptive linear prediction filter to reduce the motion artifacts in the original electrocardiogram (ECG) signal. Two filter algorithms used for baseline drift removal are evaluated to check whether real-time execution is possible on our wearable platform. The experiment results shows that the ECG signal filtered by adaptive linear prediction filter recovers from the distorted ECG signal efficiently.

Cerebral Blood Flow Monitoring by Diffuse Speckle Contrast Analysis during MCAO Surgery in the Rat

  • Yeo, Chaebeom;Kim, Heejaung;Song, Cheol
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.433-439
    • /
    • 2017
  • The rodent model has been used frequently to understand stroke pathophysiology, due to its low cost and the large spectrum of genetic strains available. Here, we present a diffuse speckle contrast analysis system (DSCA) with a $1{\times}2$ optical switch that was used to non-invasively assess cerebral blood flow (CBF) changes in the rat during intraluminal suturing for middle cerebral artery occlusion (MCAO) surgery. The blood flow index (BFI) in the left hemisphere was lower than that in the right hemisphere because the left middle cerebral artery was occluded. Furthermore, the performance of the DSCA system was compared with that of commercial laser Doppler flowmetry. The changes in the BFI measured by the two systems were correlated strongly. The DSCA system was less sensitive to motion artifacts and able to measure relatively deep tissue flow in the rat's brain. In conclusion, the DSCA system secured CBF monitoring during surgery in a rodent model without craniotomy.

Application of Functional Near-Infrared Spectroscopy to the Study of Brain Function in Humans and Animal Models

  • Kim, Hak Yeong;Seo, Kain;Jeon, Hong Jin;Lee, Unjoo;Lee, Hyosang
    • Molecules and Cells
    • /
    • 제40권8호
    • /
    • pp.523-532
    • /
    • 2017
  • Functional near-infrared spectroscopy (fNIRS) is a noninvasive optical imaging technique that indirectly assesses neuronal activity by measuring changes in oxygenated and deoxygenated hemoglobin in tissues using near-infrared light. fNIRS has been used not only to investigate cortical activity in healthy human subjects and animals but also to reveal abnormalities in brain function in patients suffering from neurological and psychiatric disorders and in animals that exhibit disease conditions. Because of its safety, quietness, resistance to motion artifacts, and portability, fNIRS has become a tool to complement conventional imaging techniques in measuring hemodynamic responses while a subject performs diverse cognitive and behavioral tasks in test settings that are more ecologically relevant and involve social interaction. In this review, we introduce the basic principles of fNIRS and discuss the application of this technique in human and animal studies.

Electromyography 기법을 이용한 육상 크라우칭 스타트의 하체 근 동원 비교분석 (Electromyography Analysis of Muscle Activities of tower limb for Crouching Start Technique)

  • 신성휴;박기자
    • 한국운동역학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 2003
  • The purposes of this study were to analyze the muscle activities and the characteristics of muscle recruting patterns of lower limb for crouching start technique using four elite splint. The EMG technique was used to record muscle activities of both right and left sides of retus femoris, vastus medialis, biceps femoris, and gastrocnemius. Eight surface electrodes were placed on the surface of the selected muscles and one ground electrode was also attached on the back of neck(C7). One video camera was also used to record the crouching start motion to define 6 events and 5 phases for further analysis. The raw EMG data were filtered with band pass filter(10-350) to remove artifacts and then low pass filtered(4Hz) to find the linear envelope which resemble muscle tension curve. This filter EMG data were normalized to MVIC for the purpose of comparison between right and left sides muscle. The results of this study were as follows. All four subjects showed that vastus medialis muscle activity was comparatively higher than those of retus femoris, biceps femoris, gastrocnemius. And left side of muscle activity was comparatively higher than right side of muscle activity. Therefore, when the subjects starting out crouching start position, we recognized that the muscle of lower limb showed interaction effect by each muscle.

윤곽과 평면 영역을 고려한 영상복원 (Image Restoration Considering the Edge and Flat Region)

  • 전우상;이태홍
    • 한국멀티미디어학회논문지
    • /
    • 제5권4호
    • /
    • pp.399-404
    • /
    • 2002
  • 움직임에 의해 흐려지고 잡음으로 훼손된 영상을 복원하는 방법은 매우 어렵다. 기존의 방법은 영상의 국부적인 특성을 고려하지 않고 영상전체에 일률적으로 정칙화를 행함으로써 윤곽부분에서는 리플잡음을 초래하고 평면부분에서도 잡음증폭을 피할 수 없으며, 또한 시각적으로 효율적이지 못한 면이 있다 이러한 문제점을 개선하기 위하여, 본 논문에서는 훼손된 영상에 전처리를 하여 방향성을 검출한 다음 평면영역과 윤곽영역의 방향특성에 따라 적응적으로 처리하는 복원방법을 제안한다. 제안한 방법은 기존의 방법과 비교하여 시각적으로 중요한 해상도를 향상시킴으로써 윤곽부분 복원에 효율적임을 실험결과를 통해 알 수 있었으며 ISNR과 MSE 면에서도 우수하였다.

  • PDF

Wearable Approach of ECG Monitoring System for Wireless Tele-Home Care Application

  • Kew, Hsein-Ping;Noh, Yun-Hong;Jeong, Do-Un
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.337-340
    • /
    • 2009
  • Wireless tele-home-care application gives new possibilities for ECG (electrocardiogram) monitoring system with wearable biomedical sensors. Thus, continuously development of high convenient ECG monitoring system for high-risk cardiac patients is essential. This paper describes to monitor a person's ECG using wearable approach. A wearable belt-type ECG electrode with integrated electronics has been developed and has proven long-term robustness and monitoring of all electrical components. The measured ECG signal is transmitted via an ultra low power consumption wireless sensor node. ECG signals carry a lot clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed thus it bring errors due to motion artifacts and signal size changes. Variable threshold method is used to detect the R-peak which is more accurate and efficient. In order to evaluate the performance analysis, R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research. This concept able to allow patient to follow up critical patients from their home and early detecting rarely occurrences of cardiac arrhythmia.

  • PDF

High Speed SD-OCT System Using GPU Accelerated Mode for in vivo Human Eye Imaging

  • Cho, Nam Hyun;Jung, Unsang;Kim, Suhwan;Jung, Woonggyu;Oh, Junghwan;Kang, Hyun Wook;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.68-72
    • /
    • 2013
  • We developed an SD-OCT (Spectral Domain-Optical Coherence Tomography) system which uses a GPU (Graphics Processing Unit) for processing. The image size from the SD-OCT system is $1024{\times}512$ and the speed is 110 frame/sec in real-time. K-domain linearization, FFT (Fast Fourier Transform), and log scaling were included in the GPU processing. The signal processing speed was about 62 ms using a CPU (Central Processing Unit) and 1.6 ms using a GPU, which is 39 times faster. We performed an in-vivo retinal scan, and reconstructed a 3D visualization based on C-scan images. As a result, there were minimal motion artifacts and we confirmed that tomograms of blood vessels, the optic nerve, and the optic disk are clearly identified. According to the results of this study, this SD-OCT can be applied to real-time 3D display technology, particularly auxiliary instruments for eye operations in ophthalmology.

다채널 말초 신경신호의 실시간 디코딩 (Real-Time Decoding of Multi-Channel Peripheral Nerve Activity)

  • 지인혁;이연정;추준욱
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.1039-1049
    • /
    • 2020
  • 신경의수를 제어하기 위해서는 사용자의 의도를 인식하는 신경신호 디코딩이 중요하다. 본 논문에서는 다채널 말초 신경신호의 실시간 디코딩 방법을 제안한다. 말초 신경신호는 정중신경과 요골신경에서 측정되었으며 운동잡음은 국소 근사 다항식에 의해 제거되었다. 다음으로 활동전위는 k-평균 알고리즘으로 분류되었다. 특징벡터는 활동전위의 발화율로부터 추출되었으며 자기 조직화 특징지도를 통해 차원이 축소되었다. 마지막으로 다층 퍼셉트론으로 손동작을 분류하였다. 원숭이 실험에서 모든 신호처리가 실시간 제한조건 이내에 완료되었으며 높은 성공률로 손동작을 인식할 수 있었다.

s-IGDT 시스템의 X-선원 배열 형태 및 투영상 개수에 따른 영상 화질 평가에 관한 연구 (Image Quality Evaluation according to X-ray Source Arrangement Type and the Number of Projections in a s-IGDT System)

  • 이다혜;남기복;이승완
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.117-125
    • /
    • 2022
  • Although stationary inverse-geometry digital tomosynthesis (s-IGDT) is able to reduce motion artifacts, image acquisition time and radiation dose, the image quality of the s-IGDT is degraded due to the truncations arisen in projections. Therefore, the effects of geometric and image acquisition conditions in the s-IGDT should be analyzed for improving the image quality and clinical applicability of the s-IGDT system. In this study, the s-IGDT images were obtained with the various X-ray source arrangement types and the various number of projections. The resolution and noise characteristics of the obtained s-IGDT images were evaluated, and the characteristics were compared with those of the conventional DT images. The s-IGDT system using linear X-ray source arrangement and 40 projections maximized the image characteristics of resolution and noise, and the corresponding system was superior to the conventional DT system in terms of image resolution. In conclusion, we expect that the s-IGDT system can be used for providing medical images in diagnosis.