• 제목/요약/키워드: Mortar wall

검색결과 109건 처리시간 0.021초

Experimental and numerical analysis of new bricks made up of polymer modified-cement using expanded vermiculite

  • Koksal, Fuat;del Coz Diaz, Juan J.;Gencel, Osman;Alvarez Rabanal, Felipe P.
    • Computers and Concrete
    • /
    • 제12권3호
    • /
    • pp.319-335
    • /
    • 2013
  • In this paper, the properties of the cement mortar modified with styrene acrylic ester copolymer were investigated. Expanded vermiculite as lightweight aggregate was used for making the polymer modified mortar test specimens. To study the effect of polymer-cement ratio and vermiculite-cement ratio on various properties, specimens were prepared by varying the polymer-cement and vermiculite-cement ratios. Tests of physical properties such as density, water absorption, thermal conductivity, three-point flexure and compressive tests were made on the specimens. Furthermore, a coupled thermal-structural finite element model of an entire corner wall was modelled in order to study the best material configuration. The wall is composed by a total of 132 bricks of $120{\times}242{\times}54$ size, joined by means of a contact-bonded model. The use of advanced numerical methods allows us to obtain the optimum material properties. Finally, comparisons of polymer-cement and vermiculite-cement ratios on physical properties are given and the most important conclusions are exposed.

Design of interlocking masonry units and mechanical properties of masonry assemblages

  • Husema, Metin;Kayaalp, Fatma Birinci
    • Computers and Concrete
    • /
    • 제23권2호
    • /
    • pp.97-106
    • /
    • 2019
  • This paper describes the design of a new interlocking masonry system, the production of designed interlocking units and mechanical properties of interlocked masonry assemblages with mortar. In this proposed system, units have horizontal and vertical locks to integrate the units to the wall and have a channel to enable the use of horizontal reinforcements in the wall. Using these units, unfilled, filled or reinforced walls can be constructed with or without mortar. In the production of the interlocking units, it was decided to use foamed concrete. 12 trial productions have been carried out at different mix proportions to obtain the optimum concrete mix. At the end of the mentioned productions, the units were produced with foam concrete which is selected as the most suitable in terms of compressive strength and specific gravity. Then, axial compression, diagonal tension and bed joint shear tests were carried out to determine the mechanical properties of the interlocked masonry assemblages with mortar. Results from the tests showed that interlocks designed to strengthen the system against shear stresses by creating discontinuity throughout the joints have been successful to achieve their aim. Obtained data will enable structural analysis of walls to be constructed with these new units.

Investigation of masonry elasticity and shear moduli using finite element micro-models

  • Mavrouli, O.A.;Syrmakezis, C.A.
    • Smart Structures and Systems
    • /
    • 제4권2호
    • /
    • pp.171-182
    • /
    • 2008
  • In this paper, a methodology for the estimation of masonry elasticity and shear moduli is presented, for linear elasticity considerations. The methodology is based on the assumption that for a "periodic" masonry wall, which is formed by the repetition of a basic unit containing blocks and mortar, the mechanical characteristics of the unit are representative of the characteristics of the entire wall. For their calculation, the finite element analysis method is used. A micro-model with finite elements simulating separately the blocks and the mortar is developed. An equivalent finite element model, using an homogenous material is also developed and assuming equivalence of strains for the two models, the homogenous material properties are estimated. The efficiency of the method and its applicability limits are investigated.

청구 스플라이스 슬리브 시스템 개발에 관한 연구 (A Study on the Development of Chonggu Splice-Sleeve System)

  • 곽철승;이용재;이동우;김병균;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.508-513
    • /
    • 1996
  • The purpose of this paper, having chosen the connection method, filled by High-strength mortar, in conncetion of PC member, is to study the mechanical behaviour and practical usage of the method. The paper estimates the connection ability of Reinforced-bar, that is, Sleeve considering the effect of Reinforced-bar's dimeter. Sleeve's length and diameter in the structural behaviour of mortar-filled connection, therefore the behaviour of Splice-Sleeve exists in concrete practically. This paper discusses the effect of the concrete in Splice-Sleeve. Also, to estimate structural behaviour in a practical wall panel, the upper and bottom wall panels are produced and the behaviour of Splice-Sleeve is discussed. And then Vertical Tie Bar being designed by using Precast method, this paper presents the various application and the practicable method using Splice-Sleeve.

  • PDF

명동성당 외부 벽돌벽의 보수.보존을 위한 석회몰탈 성분 분석에 관한 연구 - 동쪽 벽면 보수 공사를 중심으로 - (A Study on the Analysis of Lime Mortar Composition for the Preservation of Myung Dong Cathedral Church - Focused on the East Brick Wall -)

  • 김종헌;김정동;김택남;김태우
    • 건축역사연구
    • /
    • 제14권2호
    • /
    • pp.89-101
    • /
    • 2005
  • The bricks in Myung Dong Cathedral Church are now deteriorated by the weather such as temperature, humidity, and winds. Thus it is necessary to replace the old bricks to the restored bricks for the load bearing capacity as well as to prevent the penetrations of rains from outside. However the mortar composition is not well defined at this moment and there are literary about the mortar completions. Thus it is necessary to verify the mortar compactions between old bricks and results to bring the restoring the mortar for the replace of new bricks. The particles of mortar was collected from Myung Dong Cathedral Church and particle size was analyzed by the mortar and pestle and mechanicle floater. The X-ray diffraction and XRF of each particles are analyzed. The quartz and feldspar such as albite, kaolinite are observed in large particles(>1mm). However, the clicite was observed at lower than $43{\mu}m$ particles. In XRF analysis, the $SiO_2\;and\;K_2O$ are observed at large particles$(1mm-208{\mu}m)\;and\;CaCO_3$ is observed at small particles$(208-43{\mu}m)\;and\;CaCO_3$ is observed at small particles($208-43{\mu}m$). This is well coincide with XRD results. The optimum volume ratio of lime mortar would be 1: 2 ($CaO: SiO_2$).

  • PDF

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

상수도관로중 주철관종의 잔존수명 평가에 관한 연구 (Residual Life Assessment on Cast Iron Pipes of Water Distribution System)

  • 이현동;배철호;홍성호;황재운;곽필재
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.206-214
    • /
    • 2004
  • Residual wall thicknesses, corrosion rates, and residual life of thirty four samples of cast iron pipes(CIPs) and ductile cast iron pipes(DCIPs) collected from water mains of B city were studied to estimate their remaining service life or optimum time of rehabilitation. The internal maximum corrosion depths of samples measured using a dial gauge after shot blasting were twice higher than the external in most cases. Therefore corrosion of water pipes was much more affected by internal water quality than soil. Residual wall thicknesses of DCIPs were higher than those of CIPs. That reason was thought to be that DCIPs have been protected from internal corrosion by lining cement mortar. Residual life calculated by maximum corrosion rate was ranged up to 44 years with 12.40 years average. Since most CIPs were much deteriorated, rehabilitation plan should be established soon in B city. Residual life of DCIP was 33.52 years average. When cement mortar lining is used up by neutralization of DCIPs. DCIP also should be rehabilitated.

Discontinuous deformation analysis for reinforced concrete frames infilled with masonry walls

  • Chiou, Yaw-Jeng;Tzeng, Jyh-Cherng;Hwang, Shuenn-Chang
    • Structural Engineering and Mechanics
    • /
    • 제6권2호
    • /
    • pp.201-215
    • /
    • 1998
  • The structural behavior of reinforced concrete frame infilled with a masonry wall is investigated by the method of discontinuous deformation analysis (DDA). An interface element is developed and it is incorporated into DDA to analyze the continuous and discontinuous behavior of the masonry structure. The numerical results are compared with previous research and possess satisfactory agreement. Then the structural behavior and stress distribution of a reinforced concrete frame infilled with a masonry wall subjected to a horizontal force are studied. In addition, the justification of equivalent strut is assessed by the distribution of principal stresses. The results show that the behavior of the masonry structure is highly influenced by the failure of mortar. On the basis of the distribution of principal stress of the masonry wall in the reinforced concrete frame, the equivalent strut can be approximately substituted for the masonry wall without separation and opening. However, the application of equivalent strut to the masonry wall with separation and opening needs further study.

이상범 가옥 및 화실 내 꽃담의 재료학적 특성과 보존처리 (Material Characteristics and Conservation Treatment for Floral Wall in Lee Sang-beom's House and Atelier)

  • 김소진;한민수;이원동;한병일
    • 보존과학회지
    • /
    • 제27권3호
    • /
    • pp.313-322
    • /
    • 2011
  • 등록문화재 제171호인 이상범 가옥 및 화실의 꽃담을 보존처리하였으며, 처리 중 탈락된 시편의 과학적 분석을 통해 재료학적 특성 및 제작기법을 파악하였다. 분석 결과, 꽃담은 시멘트 블록으로 만든 벽체와 시멘트 모르타르로 만든 화면, 그리고 구조적인 보강을 위해 덧바른 시멘트 모르타르, 시멘트 페이스트 층으로 구성되었다. 꽃담의 시멘트 모르타르 층은 상부로 갈수록 세립의 광물질을 사용했으며, 풍화가 일어나지 않아 공극 및 탄산칼슘($CaCO_3$)의 생성이 적음을 알 수 있었다. 화면은 다양한 색상을 표현하기위해 시멘트 모르타르에 탄소화합물(C), 철산화물($Fe_2O_3$) 및 호분($CaCO_3$, 또는 석회) 등의 무기안료를 혼합하여 부조와 투조 기법으로 제작되었다. 보존처리는 벽체에 구조적인 안정성을 주기 위해 스테인레스 프레임을 제작하여 설치하였으며, 표면의 시멘트 모르타르를 제거함과 동시에 훼손부 및 균열부를 KSE Filler A, B로 메움처리 하였다.

국가등록문화재로 지정된 옛 담장의 정비 양상 (A Study on Structural Maintenance of 'Old Wall' Designated as National Registered Cultural Heritage )

  • 소현수;정명석
    • 한국전통조경학회지
    • /
    • 제41권1호
    • /
    • pp.21-34
    • /
    • 2023
  • 본 연구는 13개 마을 옛 담장의 국가등록문화재 지정 당시 사용된 재료와 축조법을 파악하고, 현장조사를 중심으로 정비에 따른 옛 담장의 구조별 변화 양상을 고찰하였다. 연구의 결과는 다음과 같다. 첫째, 옛 담장은 토석담 10개소와 돌담 5개소로 구성되었으며, 지정 당시 자연석 메쌓기로 막쌓은 돌담은 비슷한 형태를 유지하는 비율이 높았지만, 토석담은 사용한 돌과 줄눈 및 맞댄 면 축조법에 따라서 담장별로 다양하게 변형되었다. 둘째, 옛 담장의 정비로 인해서 변화된 구간을 추출하고 재료의 대체와 첨가, 축조법의 변형 양상을 파악하였다. 지붕부는 내구성과 가격의 효율이 높은 시멘트 기와나 석면 슬레이트로 대체되고, 우수 유입을 막고자 한식 기와에 와구토가 첨가되었다. 벽체부의 자연석은 시공 편의에 따른 발파석, 마름돌, 가공 석재로 대체되고, 보수에 시멘트 블록, 시멘트 벽돌이 사용되었으며, 시멘트 모르타르가 도포되었다. 토석담의 막쌓기가 빗쌓기로 변형되고 찰쌓기는 메쌓기로 바뀌어 경관적, 구조적 문제를 야기하였다. 또한 기초부에 시멘트 모르타르층이 시공되어 자연석 메쌓기로 유도했던 우수의 흐름을 막아버렸다. 셋째, 이러한 정비 양상은 주거공간에 배치된 옛 담장의 속성상 소유주가 일상적 훼손에 대한 비전문적 보수를 반복하고, 문화재 지정으로 인하여 정비를 담당한 수리업체가 지역 재료를 수급하기 어려우며, 옛 담장에 대한 차별성있는 수리시방서가 적용되지 않는 환경에서 기인한다고 판단된다.