Investigation of a blind-deconvolution framework after noise reduction using a gamma camera in nuclear medicine imaging

  • Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2594-2600
    • /
    • 2020
  • A gamma camera system using radionuclide has a functional imaging technique and is frequently used in the field of nuclear medicine. In the gamma camera, it is extremely important to improve the image quality to ensure accurate detection of diseases. In this study, we designed a blind-deconvolution framework after a noise-reduction algorithm based on a non-local mean, which has been shown to outperform conventional methodologies with regard to the gamma camera system. For this purpose, we performed a simulation using the Monte Carlo method and conducted an experiment. The image performance was evaluated by visual assessment and according to the intensity profile, and a quantitative evaluation using a normalized noise-power spectrum was performed on the acquired image and the blind-deconvolution image after noise reduction. The result indicates an improvement in image performance for gamma camera images when our proposed algorithm is used.

An Antenna Shuffling Scheme for DSTTD System Based on Post-processing Signal to Noise Ratio (수신 신호 대 잡음비에 기반한 안테나 셔플링을 적용 DSTTD 시스템)

  • Jung Sunghun;Shim Seijoon;Lee Chungyong;Youn Dae Hee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.1
    • /
    • pp.75-80
    • /
    • 2005
  • A new antenna shuffling scheme for double space time transmit diversity is proposed. The proposed method obtains the shuffling pattern directly from the estimated channel by maximizing minimum post-processing signal to noise ratio(SNR), while the conventional method minimizes channel correlation. Since the minimum post-processing SNR is directly related with error performance, the proposed method shows better bit error rate performance than the conventional method. Monte Carlo simulations showed that the proposed scheme has more 3 dB SNR gain than the conventional scheme for 10/sup -3/ bit error rate in spatially correlated fadingcaused by a single cluster model.

Efficient Performance Evaluation Method for IS-95 System (IS-95 시스템 역방향 채널에서의 효율적인 성능평가 기법)

  • 전재춘;고윤진;정미선;황인관
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4B
    • /
    • pp.345-352
    • /
    • 2002
  • In this paper, in order to evaluate the performance of IS-95 system reverse link in white gaussian noise and rayleigh fading environment, we suggest epochal proposal to improve computer run-time and its efficiency is verified in terms of the number of samples. MC(Monte Carlo) simulation is the most popular simulation technique lately, but MC simulation requires a number of samples at low bit error rate. Therefore, MC cannot avoid the limit of computer run-time. To alleviate these problems, we apply the suggested method called central moment technique to the reverse link of the IS-95 system and can obtain discrete probability mass functions from Nth order central moments of the less number of received signal samples than those required in MC. Continuous cumulative probability distribution function can be accurately estimated by using interpolation and the improvement effect for the number of samples is proven.

Sensing changes in tumor during boron neutron capture therapy using PET with a collimator: Simulation study

  • Yang, Hye Jeong;Yoon, Do-Kun;Suh, Tae Suk
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2072-2077
    • /
    • 2020
  • The purpose of this study was to demonstrate the feasibility of sensing changes in a tumor during boron neutron capture therapy (BNCT) using a Monte Carlo simulation tool. In the simulation, an epi-thermal neutron source and a water phantom including boron uptake regions (BURs) were simulated. Moreover, this simulation also included a detector for positron emission tomography (PET) scanning and an adaptively-designed collimator (ADC) for PET. After the PET scanning of the water phantom, including the 511 keV source in the BUR, the ADC was positioned in the PET's gantry. Single prompt gamma rays were collected through the ADC during neutron irradiation. Then, single prompt gamma ray-based tomography images of different sized tumors were acquired by a four-step process. Both the signal-to-noise ratio (SNR) and tumor size were analyzed from each step image. From this analysis, we identified a decreasing trend of both the SNR and signal intensity as the tumor size decreased, which was confirmed in all images. In conclusion, we confirmed the feasibility of sensing changes in a tumor during BNCT using PET and an ADC through Monte Carlo simulation.

The effect of model parameters on single dipole source tracing in EEG (모델 변수가 EEG의 Single Dipole Source 추정에 끼치는 영향에 관한 연구)

  • 박기범;박인호;김동우;배병훈;김수용;박찬영;김신태
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.41-53
    • /
    • 1994
  • The accurate localization of electrical sources in the brain is one of the most important questions in EEG, especially in the analysis of evoked responses and of epileptiform spike activity. A detailed simulation study of single dipole source estimation based on EEG is given in this paper. The effects of dipole model parameters on single dipole source tracing in EEG are examined in some detail using the Monte Carlo simulation. The error of source localization is found to be greatly influenced by how the electrodes are distributed over the head and the number of them.

  • PDF

Simplified Maximum Likelihood Estimation of the Frequencies of Multiple Sinusoids (간략화된 최우도 방법을 사용한 다중 정현파의 주파수 추정)

  • Ahn, Tae-Chon;Oh, Sung-Kwun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.20-31
    • /
    • 1994
  • The maximum likelihood(ML) estimation has excellent accuracy for frequency estimation of multiple sinusoids, but the maximum likelihood function requires much loss owing to the high nonlinearity. This paper presents a simplified maximum likelihood estimation, in order to improve the nonlinearity of the maximum likelihood estimation for frequencies of sinusoids in signals. This method is applied to the frequency estimation of sinusoidal signals corrupted by white or colored measurement noise. Monte-carlo simulations are conducted for the comparison of ML method with the best MFBLP method, in terms of sampled mean, root mean square and relative bias. The power spectral density and the position of frequency in unit circle are appeared in figures.

  • PDF

Light Contribution Based Importance Sampling for the Many-Light Problem (다광원 문제를 위한 광원 기여도 기반의 중요도 샘플링)

  • Kim, Hyo-Won;Ki, Hyun-Woo;Oh, Kyoung-Su
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06b
    • /
    • pp.240-245
    • /
    • 2008
  • 컴퓨터 그래픽스에서 많은 광원들을 포함하는 장면을 사실적으로 렌더링하기 위해서는, 많은 양의 조명 계산을 수행해야 한다. 다수의 광원들로부터 빠르게 조명 계산을 하기 위해 많이 사용되는 기법 중에 몬테 카를로(Monte Carlo) 기법이 있다. 본 논문은 이러한 몬테 카를로(Monte Carlo) 기법을 기반으로, 다수의 광원들을 효과적으로 샘플링 할 수 있는 새로운 중요도 샘플링 기법을 제안한다. 제안된 기법의 두 가지 핵심 아이디어는 첫째, 장면 내에 다수의 광원이 존재하여도 어떤 특정 지역에 많은 영향을 주는 광원은 일부인 경우가 많다는 점이고 두 번째는 공간 일관성(spatial coherence)이 낮거나 그림자 경계 지역에 위치한 픽셀들은 영향을 받는 주요 광원이 서로 다르다는 점이다. 제안된 기법은 이러한 관찰에 착안하여 특정 지역에 광원이 기여하는 정도를 평가하고 이에 비례하게 확률 밀도 함수(PDF: Probability Density Function)를 결정하는 방법을 제안한다. 이를 위하여 이미지 공간상에서 픽셀들을 클러스터링(clustering)하고 클러스터 구조를 기반으로 대표 샘플을 선정한다. 선정된 대표 샘플들로부터 광원들의 기여도를 평가하고 이를 바탕으로 클러스터 단위의 확률 밀도 함수를 결정하여 최종 렌더링을 수행한다. 본 논문이 제안하는 샘플링 기법을 적용했을 때 전통적인 샘플링 방식과 비교하여 같은 샘플링 개수에서 노이즈(noise)가 적게 발생하는 좋은 화질을 얻을 수 있었다. 제안된 기법은 다수의 조명과 다양한 재질, 복잡한 가려짐이 존재하는 장면을 효과적으로 표현할 수 있다.

  • PDF

The Influence of the Number of Electrodes, the Position and Direction of a Single Dipole on the Relation Between S/N ratio and EEG Dipole Source Estimation Errors (뇌전위의 단일 쌍극자 모델에서 전극의 개수, 쌍극자의 위치 및 방향이 S/N과 쌍극자 추정 오차사이의 관계에 미치는 영향에 관한 시뮬레이션 연구)

  • 김동우;배병훈
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.71-76
    • /
    • 1994
  • In the source localization using single dipole model, the influence of the number of electrodes, the position and direction of a single dipole on the relation between S/W ratio and dipole parameter estimation errors is important. Monte Carlo simulation was used to investigate this influence. The forward problem was calculated using three spherical shell model, and dipole parameters were optimized by means of simplex method. As the number of electrodes became large, as the dipole went from midbrain to cortex, and as the direction of dipole changed from radial to tangential, the average and standard deviation of estimation errors became small.

  • PDF

Optimal design of stone columns reinforced soft clay foundation considering design robustness

  • Yu, Yang;Wang, Zhu;Sun, HongYue
    • Geomechanics and Engineering
    • /
    • v.22 no.4
    • /
    • pp.305-318
    • /
    • 2020
  • Stone columns are widely used to treat soft clay ground. Optimizing the design of stone columns based on cost-effectiveness is always an attractive subject in the practice of ground treatment. In this paper, the design of stone columns is optimized using the concept of robust geotechnical design. Standard deviation of failure probability, which is a system response of concern of the stone column-reinforced foundation, is used as a measure of the design robustness due to the uncertainty in the coefficient of variation (COV) of the noise factors in practice. The failure probability of a stone column-reinforced foundation can be readily determined using Monte Carlo simulation (MCS) based on the settlements of the stone column-reinforced foundation, which are evaluated by a deterministic method. A framework based on the concept of robust geotechnical design is proposed for determining the most preferred design of stone columns considering multiple objectives including safety, cost and design robustness. This framework is illustrated with an example, a stone column-reinforced foundation under embankment loading. Based on the outcome of this study, the most preferred design of stone columns is obtained.

An Interference Analysis Method with Site-Specific Path Loss Model for Wireless Personal Area Network

  • Moon, Hyun-Wook;Kwon, Se-Woong;Lee, Jong-Hyun;Yoon, Young-Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.290-295
    • /
    • 2010
  • In this paper, an interference analysis method with a site-specific path loss model for a wireless personal area network (WPAN) is proposed. The site-specific path loss model is based on geometrical optics and geometric probability to consider both site-specific radio propagation characteristics and a closed-form expression to obtain the mean interference from which the uniformly distributed multiple interferers are derived. Therefore, the proposed interference analysis method can achieve more computational simplicity than the Monte-Carlo (MC) simulation, which uses the ray-tracing (RT) technique. In addition, better accuracy than the conventional interference analysis model that uses stochastic method can also be achieved. To evaluate the proposed method, a signal to the interference-noise ratio with a mean interference concept for uniformly distributed interferers is calculated and compared in two simulation scenarios. As a result, the proposed method produces not only better matched results with the MC simulation using the RT technique than the conventional interference analysis model, but also simpler and faster calculation, which is due to the site-specific path loss model and closed-form expression for interference calculation.