• 제목/요약/키워드: Monitoring-Evaluation

검색결과 2,531건 처리시간 0.03초

소 브루셀라병 표준시험관응집반응법 진단효율 평가 (Evaluation on diagnostic efficiency of the standard tube agglutination test for bovine brucellosis)

  • 성소라;김지연;허문;이기찬;구정희;강성일;이향근;김숙미;정석찬
    • 한국동물위생학회지
    • /
    • 제35권4호
    • /
    • pp.269-273
    • /
    • 2012
  • A confirmatory serological test, the standard tube agglutination test (STAT) is evaluated for the diagnostic efficiency in brucellosis Korea. A total of 345 bovine samples were collected from regional veterinary branch under national brucellosis monitoring program from January 2010 to June 2012 in Korea. These samples were diagnosed as suspected serum and brucellosis positive by the Rose Bengal test (RBT) and the STAT, respectively. The STAT was compared and evaluated with three serological test such as the indirect-enzyme linked immunosorbent assay (I-ELISA), competitive-enzyme linked immunosorbent assay (C-ELISA) and fluorescence polarisation assay (FPA) prescribed for international trade by OIE. Among the 345 bovine serum samples, 302 (87.5%) were diagnosed as positive in the STAT, while 215 (62.3%), 223 (64.6%) and 194 (56.2%) serum samples were diagnosed as positive for brucellosis in the I-ELISA, C-ELISA and FPA, respectively. The STAT showed quite high positive results as compared with three prescribed tests of OIE. FPA, I-ELISA and C-ELISA have shown 60.6%, 64.9% and 67.2% correlation, respectively as compared to the STAT. However correlations of three prescribed tests ranged high 84.1~97.7%. Especially, correlation between I-ELISA and C-ELISA is quite high, 97.7%. These results suggest that the STAT has shown many false-positive reactions. Therefore, additional serological test, such as ELISAs and FPA, would be necessary to adopt as a confirmatory test in the national surveillance program of bovine brucellosis in Korea.

Role and Prognosis of Extracorporeal Life Support in Patients Who Develop Cardiac Arrest during or after Office-Based Cosmetic Surgery

  • Kwon, Seong Soon;Park, Byoung-Won;Lee, Min-Ho;Bang, Duk Won;Hyon, Min-Su;Chang, Won-Ho;Oh, Hong Chul;Park, Young Woo
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.277-284
    • /
    • 2020
  • Background: Cardiac arrest during or after office-based cosmetic surgery is rare, and little is known about its prognosis. We assessed the clinical outcomes of patients who developed cardiac arrest during or after cosmetic surgery at office-based clinics. Methods: Between May 2009 and May 2016, 32 patients who developed cardiac arrest during or after treatment at cosmetic surgery clinics were consecutively enrolled. We compared clinical outcomes, including complications, between survivors (n=19) and non-survivors (n=13) and attempted to determine the prognostic factors of mortality. Results: All 32 of the patients were female, with a mean age of 30.40±11.87 years. Of the 32 patients, 13 (41%) died. Extracorporeal life support (ECLS) was applied in a greater percentage of non-survivors than survivors (92.3% vs. 47.4%, respectively; p=0.009). The mean duration of in-hospital cardiopulmonary resuscitation (CPR) was longer for the non-survivors than the survivors (31.55±33 minutes vs. 7.59±9.07 minutes, respectively; p=0.01). The mean Acute Physiology and Chronic Health Evaluation score was also higher among non-survivors than survivors (23.85±6.68 vs. 16.79±7.44, respectively; p=0.01). No predictor of death was identified in the patients for whom ECLS was applied. Of the 19 survivors, 10 (52.6%) had hypoxic brain damage, and 1 (5.3%) had permanent lower leg ischemia. Logistic regression analyses revealed that the estimated glomerular filtration rate was a predictor of mortality. Conclusion: Patients who developed cardiac arrest during or after cosmetic surgery at office-based clinics experienced poor prognoses, even though ECLS was applied in most cases. The survivors suffered serious complications. Careful monitoring of subjects and active CPR (when necessary) in cosmetic surgery clinics may be essential.

서화천 유역 비점오염원 관리를 위한 부하지속곡선 적용성 연구 (A Study on the Applicability of Load Duration Curve for the Management of Nonpoint Source Pollution in Seohwacheon Basin)

  • 갈병석;문현생;홍선화;박천동;민경옥;박재범
    • 한국지리정보학회지
    • /
    • 제23권3호
    • /
    • pp.174-191
    • /
    • 2020
  • 본 연구에서는 대청호 상류에 있는 서화천 유역에서 부하지속곡선을 통한 소유역별 비점오염원 취약지역 및 관리 오염물질과 관리 시기를 분석하였다. 먼저 부하지속곡선을 만들기 위하여 장기 유출 모형인 SWAT를 구축하여 유량지속곡선(Flow Duration Curve)을 작성하였으며 그 결과에 목표 수질을 곱하여 부하지속곡선(Load Duration Curve)을 작성하였다. 목표 수질은 서화천 비점오염원 관리를 위해 지난 2017년 11월부터 측정한 모니터링 자료를 사용하였으며 측정자료의 60분위에 해당하는 값을 목표 수질로 설정하였다. 이때 산정된 값이 하천 생활환경 기준의 "약간좋음"(II)을 초과할 경우 목표 수질을 "약간 좋음"(II)으로 제한하였다. 비점오염원 취약지역은 목표 수질을 초과하는 초과율을 이용하여 선정하였으며 초과 되는 오염물질을 관리 물질로 판단하고 계절별 평가를 통해 관리시기를 선정하였다.

Assessment of Relationship between Wilms' Tumor Gene (WT1) Expression in Peripheral Blood of Acute Leukemia Patients and Serum IL-12 and C3 Levels

  • Rezai, Omran;Khodadadi, Ali;Heike, Yuji;Mostafai, Ali;Gerdabi, Nader Dashti;Rashno, Mohammad;Abdoli, Zahra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.7303-7307
    • /
    • 2015
  • Background: Leukemia is a common cancer among children and adolescents. Wilms' tumor gene (WT1) is highly expressed in patients with acute leukemia. It is found as a tumor associated antigen (TAA) in various types of hematopoietic malignancies and can be employed as a useful marker for targeted immunotherapy and monitoring of minimal residual disease (MRD). In this regard, WT1 is a transcription factor that promotes gene activation or repression depending on cellular and promoter context. The purpose of this study was assessment of WT1 gene expression in patients with acute leukemia, measurement of IL-12 and C3 levels in serum and evaluation of the relationship between them. Materials and Methods: We evaluated the expression of WT1 mRNA using real-time quantitative RT-PCR and serum levels of IL-12 and C3 using ELISA and nephelometry in peripheral blood of 12 newly diagnosed patients with acute leukemia and 12 controls. Results: The results of our study showed that the average wT1 gene expression in patients was 7.7 times higher than in healthy controls (P <0.05). In addition, IL-12 (P = 0.003) and C3 (P <0.0001) were significantly decreased in the test group compared to controls. Conclusions: WT1 expression levels are significantly higher in patients compared with control subjects whereas serum levels of interleukin-12 and C3 are significantly lower in patients. Wt1 expression levels in patients are inversely related with serum levels of IL-12 and C3.

초·중·고등학교의 이산화탄소 농도 및 환기량 평가 (Evaluation of Carbon Dioxide Concentrations and Ventilation Rates in Elementary, Middle, and High Schools)

  • 최영태;허정;박진현;김은채;류현수;김동준;조만수;이채관;이종대;양원호
    • 한국환경보건학회지
    • /
    • 제46권3호
    • /
    • pp.344-352
    • /
    • 2020
  • Objectives: Much attention has been paid to indoor air quality. Ventilation within schools is important because of indoor air quality and its effect on health and learning performance. In this study, we evaluated the carbon dioxide (CO2) concentrations and ventilation rates in schools. Methods: This study measured the concentration of CO2 in elementary, middle, and high school classrooms over six months. The seasons during the study were summer, fall, and winter. Sensor-based monitoring was used and the basic characteristics of the classroom were investigated. The body surface area of the students was used to calculate the CO2 generation rate, and the air change per hour (ACH) was evaluated using mass balance modeling. Results: The average CO2 concentration measured in most schools exceeded 1000 ppm. The ventilation rates varied from season to season. Compared to the recommended ventilation rate of 4.9 ACH, the roughly 3 ACH calculated in this study indicates that most schools possessed insufficient ventilation. Conclusions: The concentration of CO2 in school classrooms could be an indicator of indoor air quality and can affect students' learning ability. In this study, CO2 concentrations exceeding the standard indicate a lack of ventilation along with problems with indoor air quality. Therefore, appropriate improvements are needed to overcome these problems.

강재 수문의 부재 위치 및 설치 방향에 따른 상대 부식속도 평가 (Evaluation of Relative Corrosion Rate depending on Local Location and Installation of Structural Member in Steel Water Gate)

  • 하민균;정영수;박승훈;안진희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.16-24
    • /
    • 2019
  • 강재로 제작된 구조물의 부식량은 설치형태에 따라 상이하게 나타나므로 그에 따른 효율적인 관리가 필요하다. 본 연구에서는 강재 수문의 설치형태와 높이에 따른 부식량과 부식속도를 평가하기 위하여 설치형태와 높이에 따라 모니터링 시험체와 부식환경측정 센서를 설치하여 대기노출실험을 실시하였다. 노출기간에 따라 모니터링 시험체를 회수하여 중량감소법으로 평가된 평균부식두께와 부식환경측정센서를 통하여 계측된 갈바닉 부식전류량과의 상관관계를 이용하여 강재 수문의 설치형태와 높이에 따른 향후 부식량을 예측하였다. 본 연구 결과 수문의 가로보 수평부재는 상대적으로 가로보 스킨플레이트 부재 등의 부식손상량과 비교하면 매우 크게 발생하고 있으며, 수문 부재의 국부적 환경에 따라 부식속도가 크게 영향을 받을 수 있음을 확인할 수 있었다. 따라서 강재 수문의 국부적 부식환경 차이에 따른 부식손상 수준을 고려한 수문의 적절한 유지관리가 필요할 것으로 판단된다.

구조안전도 평가를 위한 동적변위 기반 손상도 추정 기법 개발 (Damage estimation for structural safety evaluation using dynamic displace measurement)

  • 신윤수;김준희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.87-94
    • /
    • 2019
  • 최근 구조물 계측분야에서 구조물의 동적 변위응답 측정에 관한 연구가 주목을 받고 있다. 본 연구는 이와 같은 동적 변위데이터의 활용도를 넓히고자 구조안전도 평가를 위한 방법론 제시를 목표로, 동적 변위데이터를 활용하여 부공간 시스템 식별법이 적용된 구조물 물리량 추정기법을 개발하였다. 진동 변위 데이터로부터의 상태공간모델을 추정하기 위한 부공간 시스템 식별 이론과 시스템의 물리량을 도출하기 위한 물리해석 기법을 제시하였고 실험적 검증을 위해 동적 실험을 수행하였다. 3자유도 철골 구조물을 제작하여 진동대를 활용해 지반 가진하여 각 층의 변위 데이터와 진동대의 가속도 데이터를 계측하였다. 계측된 데이터를 활용해 이산화 된 상태공간모델을 생성하였고 정밀도 파악을 위해 상태공간방정식을 통한 전산 해석을 수행하였으며, 철제 구조물의 상태공간모델로부터 층강성을 추출하였다. 또한 상태공간모델로부터 추출된 층강성을 기준으로 5가지의 기둥강성 보강 및 손상 시나리오를 설정하여 매 시나리오별 층강성 변화율을 추출하였으며 동일한 조건의 보강 및 손상의 경우, 강성 변화가 높은 일치율을 보이는 것을 확인하였다.

막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가 (Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring)

  • 이용수;강하영;김형수;김종오
    • 멤브레인
    • /
    • 제27권3호
    • /
    • pp.248-254
    • /
    • 2017
  • 내염소성 원생동물인 크립토스포리디움, 지아디아 등 병원성 미생물의 제거에 대한 신뢰성을 확보하기 위해 정수처리 공정에서 막여과 시스템이 각광받고 있으며, 이러한 신뢰성을 보증하기 위해 막 완결성에 대한 연구가 중요시되고 있다. 막 완결성 시험은 크게 직접법과 간접법으로 분류되는데, 직접법 중 압력기반의 시험은 버블포인트 이론을 근간으로 병원성 미생물의 최소 크기인 $3{\mu}m$ 크기 이상을 감지할 수 있는 감도로 USEPA Guidance Manual에서 제시하고 있다. 간접법은 온라인 상태에서 연속적인 운전이 가능하다는 점에서 널리 사용되지만, 직접법에 비해 현저히 낮은 막 손상 감지 감도를 가지고 있으며, 손상 부위를 특정 지을 수 없는 한계가 있기에 이러한 감지 감도를 개선해야 할 필요가 있다. 따라서 본 연구에서는 압력 손실 시험에 의한 막 완결성 시험을 통해 막 파단 형태별, 파단 개수, 초기설정압력값에 따른 압력손실률과 LRVDIT 신뢰성 범위를 상호 비교함으로써 막 손상에 따른 감도의 결과를 정량화하여 UCL 기준을 나타내어 비교 평가하였다.

Trap을 이용한 공주보 아이스하버식 어도의 효과분석 (Efficiency Analysis of the Ice Harbor Type Fishway Installed at the Gongju Weir on the Geum River using Traps)

  • 이진웅;윤주덕;김정희;박상현;백승호;윤조희;장민호
    • 환경생물
    • /
    • 제33권1호
    • /
    • pp.75-82
    • /
    • 2015
  • 댐과 보의 건설로 인한 하천의 단절 및 어류의 이동 문제를 해결하기 위해 다수의 어도를 건설하고 있다. 하지만 이에 대한 어도 효율성 평가나 적합성에 대한 연구는 상당히 제한적으로 이루어지고 있다. 따라서 본 연구는 2012년 6월부터 10월까지 매달 1회씩 trap을 이용하여 공주보에 설치된 아이스하버식 어도에서 시기별, 시간대별, 어도 위치별 어도 이용 차이를 분석하였다. 연구 결과, 6~8월보다 9~10월에 어도를 이용하는 종 및 개체가 감소하였다. 그리고 어도 좌안 측면이 통계적으로 유의하지 않지만 많은 종 및 개체가 출현하였고, 또한 다른 위치보다 다양한 크기의 개체들이 출현하였다. 상류수위와 채집된 소상 어류 개체수는 양의 상관성을 나타내고 있었다. 그러나 일평균 상류수위가 증가할수록 전장 70 mm 이하 소형개체들의 출현율이 감소하는 경향이 나타났다. 어도 내 시간대별 이동은 종별 생태적인 특성에 따라 차이를 보였다. 전체적으로 크기가 작은 개체부터 큰 개체까지 다양한 크기의 어류가 어도를 이용했다. 이러한 결과는 국내에 건설된 아이스하버식 어도관리 및 평가에 도움이 될 것으로 판단된다.

벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구 (An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater)

  • 백남춘;김성범;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.