• 제목/요약/키워드: Monitoring-Evaluation

검색결과 2,548건 처리시간 0.036초

고속주행을 고려한 터널 및 사면의 계측시스템 분석 및 개선 방안 연구 (Analysis and development of measurement systems for tunnels and slopes under a high velocity)

  • 정재훈;박윤제;이래철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1376-1381
    • /
    • 2010
  • In this study, we dealt with an analysis and development of measurement systems for tunnel and slope structures under a high velocity. Deterioration of tunnel and slope structures becomes a critical issue in regard to both safety and economic concerns. Deterioration itself is inevitable, but condition assessment technology and nondestructive evaluation techniques could provide solutions to ensure public safety by means of detecting damage before serious and expensive degradation consequences occur. We reviewed the existing monitoring and maintenance systems of slopes and tunnels and more advanced directions, especially for highways under high-speed vehicles.

  • PDF

수학 학습에서의 메타-정의 유형 탐색 (Explorating Meta-Affect Types in Mathematical Learning)

  • 김선희;박정언
    • 대한수학교육학회지:학교수학
    • /
    • 제13권3호
    • /
    • pp.469-484
    • /
    • 2011
  • 본 연구는 수학 학습의 정의적 영역에서 메타-정의의 개념을 구체화하고 명확히 하기 위해 메타-정의의 유형을 구분하고, 실제 사례를 보여주었다. 메타-정의는 정의의 모니터링, 감정의 평가, 감정의 조절, 정의의 활용 4가지로 구분되었고, 모니터링 후 평가, 조절, 활용이 시간적 순서로 이루어지는 것을 볼 수 있었다. 감정을 평가하고 조절하는 데 수학과 수학 학습에 대한 신념이 중요한 잣대로 작용하였으며, 메타-정의는 정의를 조절하고 학습 전략을 선정하는 등 수학 학습에서 중요한 역할을 하였다.

  • PDF

대기오염공정시험법의 체계구축과 개선방향 (Current Status and Prospects of Standard Methods for the Measurements of Air Pollution in Korea)

  • 김기현;배민석
    • 한국대기환경학회지
    • /
    • 제29권4호
    • /
    • pp.439-446
    • /
    • 2013
  • In this research, the present standard analytical methods for the monitoring of air pollution levels established by the Korean Ministry of Environment (KMOE) were examined in reference to the recent outputs of several research projects conducted for their amendments. The evaluation of the two criterion methods between the main (the present guideline) and reference methods (the proposed alternate guideline) was made in terms of authenticity and reliability of the quality assurance (QA) and of compatibility of methods. The results of this comparative evaluation are presented for the analysis of both ambient air and source samples. Based on this analysis, we propose a new direction for the future amendment.

현장타설 말뚝 공법의 지반진동이 정밀장비에 미치는 영향성 평가 (The Study on The Evaluation of The Ground Vibration of Cast in Place Concrete Pile Method Effect to Precision Equipment)

  • 홍병국;김영찬;장강석;윤제원;심상덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.97-102
    • /
    • 2011
  • The size of TV and TFT-LCD are bigger and bigger for the next generation exposure equipment install that existing fab are getting a lot of additions. When the new fab build an extension that the shortening of the construction and non-vibration are use cast in place concrete pile method. In this study when lay the foundation of existing fab adjoin use vibration monitoring system are rotator type all casing method among cast in place concrete pile method. The evaluation of ground vibration of rotator type all casing method effect to precision equipment and vibration area of influence.

  • PDF

몰드성형 광학렌즈를 이용한 의료기기용 열화상카메라 체열진단의 적용도 평가 (Evaluation of Thermography Camera Using Molded Optical Lens for Medical Applications)

  • 유성미;김혜정
    • 한국전기전자재료학회논문지
    • /
    • 제26권8호
    • /
    • pp.624-628
    • /
    • 2013
  • With the recent development of less-costly uncooled detector technology, expensive optics are among the remaining significant cost drivers in the thermography camera. As a potential solution to this problem, the fabrication of IR lenses using chalcogenide glass has been studied in recent years. We report on the molding and evaluation of a ultra-precision chalcogenide-glass lens for the thermography camera for body-temperature monitoring. In addition, we fabricated prototype thermography camera using the chalcogenide-glass lens and obtained the thermal image from the camera. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ through the analysis of thermal image. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

자기베어링 모니터링용 광파이버센서의 성능 평가 (The Performance Evaluation of Fiber Optic Sensor for Monitoring Magnetic Bearing)

  • 박한수;정택구;홍준희;이동주
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.411-416
    • /
    • 2002
  • In a high speed spindle system, it is very important to monitor the state of rotating rotor. Particularly in active control spindle system, the position sensor must provide feedback to the control system on the exact position of the rotor. In order to monitor the state of a high speed spindle exactly, high accuracy and wide frequency bandwidth of sensors are important. The focus in this paper is to make a fiber optic sensor for monitoring rotor of magnetic bearing, to design the circuit for detecting optical signal, and to evaluation static and dynamic characteristics of fiber optic sensor.

  • PDF

정보시스템 평가를 위한 과정 기반 다차원 관리 모형 설계 (Multi-Dimensional Management Model on the Basis of Process to Evaluate Information Systems)

  • 이상원;김성현;박승범;안현섭
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2014년도 제50차 하계학술대회논문집 22권2호
    • /
    • pp.91-92
    • /
    • 2014
  • Public organizations and enterprises have repeated to invest in development or operation of their information systems. However, these investment projects have been not taken care of in the field of administration and evaluation. Since these information systems projects have unique characteristics such as technology sensitiveness, network effectiveness, embeddedness, and externality, it is not easy to manage and monitor them. Returns of investment for information systems should nonetheless need efficient monitoring and effective analysis for them. In this research, we propose a multi-dimensional management model on the basis of process in order to evaluate information systems.

  • PDF

공기조화설비 겸용 제연설비 덕트의 성능개선을 위한 연구 (A Study on Performance Improvements about Duct of Smoke Control System Combined with Air-Conditioning Equipment)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.67-72
    • /
    • 2021
  • To ensure the safety and functionality of a railroad bridge, maintaining the integrity of the bridge via continuous structural health monitoring is important. However, most structural integrity monitoring methods proposed to date are based on modal responses which require the extracting process and have limited availability. In this paper, the applicability of the existing damage identification method based on free-vibration reponses to time-domain deflection shapes due to moving train load is investigated. Since the proposed method directly utilizes the time-domain responses of the structure due to the moving vehicles, the extracting process for modal responses can be avoided, and the applicability of structural health evaluation can be enhanced. The feasibility of the presented method is verified via a numerical example of a simple plate girder bridge.

고속주축 모니터링용 광파이버 변위센서의 레이저 다이오드 출력에 따른 성능평가 (Performance Evaluation according to Optical Power of Laser Diode of Optical Fiber Displacement Sensor for Monitoring High Speed Spindle.)

  • 박찬규;신우철;홍준희;이동주
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.376-380
    • /
    • 2004
  • This paper is to develop an optical ruer displacement sensor for monitoring high speed spindle. Proper magnitude of optical power as well as amplification of output signal are necessary to improve sensitivity of the sensor. In this paper, to meet the need of improvement of the sensor resolution, we choose proper optical power and amplification level through speculating on optical power of a laser diode.

  • PDF

플라즈마 임피이던스 정합망 실시간 CUSUM 제어 (Real Time CUSUM Control of Plasma Impedance Matching Network)

  • 김우석;김병환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1844-1845
    • /
    • 2007
  • A CUSUM control chart was used to monitor semiconductor plasma equipment. The performance of plasma monitoring was evaluated with various combinations of design variables involved in CUCUM control chart. Experimental data collected by using a real-time matching monitoring system include electrical positions of impedance and phase positions, and reflected power. The evaluation revealed that by determining specific design variables plasma states could be more strictly monitored.

  • PDF