• Title/Summary/Keyword: Monitoring-Evaluation

Search Result 2,552, Processing Time 0.023 seconds

The measurement and evaluation of local scour at a bridge pier using the profiling scour monitoring system (프로파일링 세굴 모니터링 시스템을 이용한 교각 국부세굴 계측 및 평가)

  • Shin, Jong-Hyun;Park, Hyun-Il;Shin, Seung-Hyun;Park, Kyung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.38-47
    • /
    • 2009
  • Scour means the erosion of bed material by flow change when a bridge is constructed in a stream. Scour is one of the critical factors of a bridge failure. There are several methods for the monitoring of scour near bridge foundations; Sounding rods, Magnetic sliding collar System, Sonar system, underwater camera system and so on. In general, Sonar system is preferred due to its convenience and good accuracy. In this study, the new scour monitoring system was developed using profiling sonar sensor. The new system can measure a line profile of a seabed and has small size due to the effectively designed data logger. The performance of the new scour monitoring system was evaluated at a bridge pier in tidal environment. The measured local scour depths were discussed with the result of the empirical formulas; CSU, Froehlich, Laursen and Neill.

  • PDF

Application of 4-D resistivity imaging technique to visualize the migration of injected materials in subsurface (지하주입 물질 거동 규명을 위한 4차원 전기비저항 영상화)

  • Kim, Jung-Ho;Yi, Myeong-Jong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.12a
    • /
    • pp.31-42
    • /
    • 2007
  • Dc resistivity monitoring has been increasingly used in order to understand the changes of subsurface conditions in terms of conductivity. The commonly adopted interpretation approach which separately inverts time-lapse data may generate inversion artifacts due to measurement error. Eventually the contaminated error amplifies the artifacts when reconstructing the difference images to quantitatively estimate the change of ground condition. In order to alleviate the problems, we defined the subsurface structure as four dimensional (4-D) space-time model and developed 4-D inversion algorithm which can calculate the reasonable subsurface structure continuously changing in time even when the material properties change during data measurements. In this paper, we discussed two case histories of resistivity monitoring to study the ground condition change when the properties of the subsurface material were artificially altered by injecting conductive materials into the ground: (1) dye tracer experiment to study the applicability of electrical resistivity tomography to monitoring of water movement in soil profile and (2) the evaluation of cement grouting performed to reinforce the ground. Through these two case histories, we demonstrated that the 4-D resistivity imaging technique is very powerful to precisely delineate the change of ground condition. Particularly owing to the 4-D inversion algorithm, we were able to reconstruct the history of the change of subsurface material property.

  • PDF

Distributed System Architecture Modeling of a Performance Monitoring and Reporting Tool (분산 시스템의 성능 모니터링과 레포팅 툴의 아키텍처 모델링)

  • Kim, Ki;Choi, Eun-Mi
    • Journal of the Korea Society for Simulation
    • /
    • v.12 no.3
    • /
    • pp.69-81
    • /
    • 2003
  • To manage a cluster of distributed server systems, a number of management aspects should be considered in terms of configuration management, fault management, performance management, and user management. System performance monitoring and reporting take an important role for performance and fault management. In this paper, we present distributed system architecture modeling of a performance monitoring and reporting tool. Modeling architecture of four subsystems are introduced: node agent, data collection, performance management & report, and DB schema. The performance-related information collected from distributed servers are categorized into performance counters, event data for system status changes, service quality, and system configuration data. In order to analyze those performance information, we use a number of ways to evaluate data corelation. By using some results from a real site of a company and from simulation of artificial workload, we show the example of performance collection and analysis. Since our report tool detects system fault or node component failure and analyzes performances through resource usage and service quality, we are able to provide information for server load balancing, in short term view, and the cause of system faults and decision for system scale-out and scale-up, in long term view.

  • PDF

Development of an Agricultural Data Middleware to Integrate Multiple Sensor Networks for an Farm Environment Monitoring System

  • Kim, Joonyong;Lee, Chungu;Kwon, Tae-Hyung;Park, Geonhwan;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.38 no.1
    • /
    • pp.25-32
    • /
    • 2013
  • Purpose: The objective of this study is to develop a data middleware for u-IT convergence in agricultural environment monitoring, which can support non-standard data interfaces and solve the compatibility problems of heterogenous sensor networks. Methods: Six factors with three different interfaces were chosen as target data among the environmental monitoring factors for crop cultivation. PostgresSQL and PostGIS were used for database and the data middleware was implemented by Python programming language. Based on hierarchical model design and key-value type table design, the data middleware was developed. For evaluation, 2,000 records of each data access interface were prepared. Results: Their execution times of File I/O interface, SQL interface and HTTP interface were 0.00951 s/record, 0.01967 s/record and 0.0401 s/record respectively. And there was no data loss. Conclusions: The data middleware integrated three heterogenous sensor networks with different data access interfaces.

Site Evaluation of Automated Monitoring Networks in Han River (한강수계 수질오염 자동측정망의 합리적인 측정지점 선정에 관한 조사연구)

  • Cho, Yong-Mo;Oh, Jung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.4
    • /
    • pp.91-98
    • /
    • 1997
  • At present, automated monitoring of water quality in Han river has been operated at each water treatment plant. But the automated measurement sites must be choosen newly because water source in Seoul move to the upper stream of Chamshil weir. In this study, automated monitoring sites in Han river were reviewed, and the proper sites for automated monitoring of water quality have been selected by Qual2E model, RMA model, water sampling guidline, Sanders' method and topograpical characteristics of Han river in order to resonable operate. 8 sites have been selected as follows: (1) the site of immediately after Paldang drainage (2) the left site and a right site of $Gu{\check{u}}i$ water intake (3) the left site and a right site at Noryangjin(Han river bridge) (4) the site between Shingok weir and Anyangchun confluence point(Hangju bridge) (5) the site of Chungryangchun downstream(existence) (6) the site of Tanchun downstream(existence) (7) the site of Anyangchun downstream(existence) (8) the site of Wangsukchun downstream. The results proposed resonable operating management of network and economical system built up.

  • PDF

An Integrated Air Monitoring Approach for Assessment of Formaldehyde in the Workplace

  • Dugheri, Stefano;Bonari, Alessandro;Pompilio, Ilenia;Colpo, Marco;Mucci, Nicola;Arcangeli, Giulio
    • Safety and Health at Work
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2018
  • The aim of this study is to validate an integrated air monitoring approach for assessing airborne formaldehyde (FA) in the workplace. An active sampling by silica gel impregnated with 2,4-dinitrophenylhydrazine, a passive solid phase microextraction technique using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine as on-fiber derivatization reagent, an electrochemical direct-reading monitor, and an enzyme-based badge were evaluated and tested over a range of 0.020-5.12 ppm, using dynamically generated FA air concentrations. Simple linear regression analysis showed the four methods were suitable for evaluating airborne FA. Personal and area samplings in 12 anatomy pathology departments showed that the international occupational exposure limits in the GESTIS database were frequently exceeded. This monitoring approach would allow a fast, easy-to-use, and economical evaluation of both current work practices and eventual changes made to reduce FA vapor concentrations.

Design and Implementation of OCR-based Machine Monitoring System for Small and Medium-Sized Enterprise (SMEs) (중소/중견 기업을 위한 OCR기반 설비 모니터링 시스템의 설계 및 구현)

  • Seong, Junghwan;Jeong, Jongpil
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.3
    • /
    • pp.73-79
    • /
    • 2021
  • In the wave of the 4th industrial revolution, smart factory is required in many factories. However, small and mid-sized companies (SMEs) still have aging machines and are having difficulties in the data collection stage, which is the basis of smart factories. This study proposes a low cost monitoring method by using an open source based technology that extracts data from the image of the facility control panel without the need for modification of existing facilities. The proposed method was tested and evaluated for forging facilities in automobile parts manufacturing plants through prototyping. As a result of the evaluation, it was confirmed that low-cost facility monitoring is possible, and it will help SMEs build smart factories.

Multi-resolution bolt preload monitoring based on the acoustoelastic effect of ultrasonic guided waves

  • Fu, Ruili;Mao, Ruiwei;Yuan, Bo;Chen, Dongdong;Huo, Linsheng
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.513-520
    • /
    • 2022
  • During the long-time service of a bolt, its preload may suffer slight perturbations or significant reductions. It is a dilemma to monitor preload changes at high resolution and full scale. Approaches for bolt preload monitoring with multi-resolution should be developed. In this paper, a simple and effective multi-resolution bolt preload monitoring approach using ultrasonic guided waves (UGW) is proposed. A linear relationship between the time-of-flight (TOF) variation of multi-reflected waves and preload is derived to theoretically reveal the multi-resolution properties of UGW. The variations of TOF before and after the slight preload perturbations are extracted by using a global evaluation method. Experimental results show that the signal-to-noise ratio (SNR) of the 1st, 2nd, and 3rd-reflected UGWs is larger than 20 dB. The resolution of the 2nd-reflected UGW is higher than that of the 1st-reflected UGW and lower than that of the 3rd-reflected UGW. The ultimate detectable resolutions of bolt preload (DRBP) of the 1st and 3th-reflected UGWs are 0.9% and 0.5%, respectively. By using the 1st and 3th-reflected guided waves, the bolt looseness with different degrees can be monitored simultaneously.

A Monitoring and Evaluation on the Project for Utilization of Cultural Property - Focused on the Project "Living and Breathing Hyanggyo·Seowon" in 2016 - (문화재 활용 사업 모니터링 및 평가 - 2016년 살아 숨 쉬는 향교·서원 만들기 사업을 중심으로 -)

  • Park, Dong-Seok
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.94-104
    • /
    • 2017
  • This study carried out field evaluation by experts, monitoring by the public, and visitor satisfaction survey for 77 cases of utilization of cultural property projects that received support from "Living and Breathing Hyanggyo and Seowon" in 2016. The result was 'normal' for the comprehensive evaluation, and by section, 'good' for planning, operating, performance, outcome and annual special index. The field evaluation by experts was rated as 'good', monitoring by the public was 'good', and also 'good' for visitor satisfaction survey. The advantages of the project were as follows; increased chance for enjoyment of local cultural heritage, expansion of human network for utilization of local cultural heritage, utilization of cultural heritage as community place, diversification of educational contents by using cultural heritage. On the other hand, the disadvantages were as follows; decline of program's quality, shortage of putting plan in practice, insufficient interest and participation of local government, insufficient promoting, shortage of educational contents for free semester system. At last, we suggested measures to develop the project as follows; develop program by using local characteristics, develop programs for foreigner, training experts, increasing on-line promotion, develop new lecture technique, utilization of cultural heritage as a local community place, utilization planning by each space, improvement of evaluation system, tightening up reflection of visitor's opinions, consulting for each programs.

Tuberculosis Surveillance and Monitoring under the National Public-Private Mix Tuberculosis Control Project in South Korea 2016-2017

  • Min, Jinsoo;Kim, Hyung Woo;Ko, Yousang;Oh, Jee Youn;Kang, Ji Young;Lee, Joosun;Park, Young Joon;Lee, Sung-Soon;Park, Jae Seuk;Kim, Ju Sang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.3
    • /
    • pp.218-227
    • /
    • 2020
  • Background: The national Public-Private Mix (PPM) tuberculosis (TB) control project provides for the comprehensive management of TB patients at private hospitals in South Korea. Surveillance and monitoring of TB under the PPM project are essential toward achieving TB elimination goals. Methods: TB is a nationally notifiable disease in South Korea and is monitored using the surveillance system. The Korea Centers for Disease Control and Prevention quarterly generates monitoring indicators for TB management, used to evaluate activities of the PPM hospitals by the central steering committee of the national PPM TB control project. Based on the notification date, TB patients at PPM hospitals were enrolled in each quarter, forming a cohort, and followed up for at least 12 months to identify treatment outcomes. This report analyzed the dataset of cohorts the first quarter of 2016 through the fourth quarter of 2017. Results: The coverage of sputum, smear, and culture tests among the pulmonary TB cases were 92.8% and 91.5%, respectively. The percentage of positive sputum smear and culture test results were 30.7% and 61.5%, respectively. The coverage of drug susceptibility tests among the culture-confirmed cases was 92.8%. The treatment success rate among the smear-positive drug-susceptible cases was 83.2%. The coverage of latent TB infection treatment among the childhood TB contacts was significantly higher than that among the adult contacts (85.6% vs. 56.0%, p=0.001). Conclusion: This is the first official report to analyze monitoring indicators, describing the current status of the national PPM TB control project. To sustain its effect, strengthening the monitoring and evaluation systems is essential.