• Title/Summary/Keyword: Monitoring-Evaluation

Search Result 2,531, Processing Time 0.031 seconds

Environmental Impacts of Brine from the Seawater Desalination Plants (해수담수화 시설에서 생성된 농축수의 환경적 영향)

  • Park, Seonyoung;Seo, Jinsung;Kim, Taeyun
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.1
    • /
    • pp.17-32
    • /
    • 2018
  • The need for seawater desalination is increasing in terms of securing various water resources, but few studies are available as for the environmental impact of hypersaline concentrated water (brine) discharged from desalination plants. Domestic studies are concentrated mainly on toxicity evaluation that phytoplankton, zooplankton larvae and green algae (Ulva pertusa) are negatively affected by concentrated water. The mortality of Paralichthys olivaceus showed a linear relationship with increasing salinity, and Oryzias latipes died 100% at concentrations above 60 psu. Foreign studies included monitoring cases as well as toxicity evaluations. The number of species decreased around the area where the concentrated water discharged. The hypersaline concentrated water affects the pelagic and benthic organisms. However, the fishes escaped when exposed to salinity, and the pelagic and benthic organisms resistant to salinity survived the hypersaline environment. The salinity limit and distance from the outlet was presented as the regulatory standard for bine discharge. There were differences in regulatory standards among country and seawater desalination plants, and these regulatory standards have been strengthened recently. In particular, California Water Boards were revised to ensure that the maximum daily salinity concentration does not exceed 2 psu above the ambient salinity level within 100 m of the outlet.

Evaluation on Hearing Conservation Program in the Noisy Industries (소음발생 산업장에서의 청력보존프로그램 평가)

  • Kwak, M.S.;Lee, J.T.;Kim, J.H.;Urm, S.H.;Kim, D.H.;Shon, B.C.;Lee, C.H.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.815-829
    • /
    • 1997
  • This study was performed to assist the employer to establish the effective program for hearing conservation of noisy industry. The study subjects were health care managers of an industry and the study industries were devided into two groups(Group I, 37 industries; have the workers diagnosed as noise-induced hearing loss, Group II, 41 industries; not have the workers diagnosed as noise-induced hearing loss) and the question method carried out through the face to face interview. The contents of questionnaire for OSHA's hearing conservation program(HCP) consisted of seven components: 5 questions of monitoring of employee noise exposures(component 1), 6 questions of the institution of engineering, work practice, and administrative controls for excessive noise(component 2), 8 questions of the provision of each overexposed employee with an individually fitted hearing protector with an adequate noise reduction rating(component 3), 14 questions of employee training and education regarding noise hazards and protection measures(component 4), 9 questions of baseline and annual audiometry(component 5), 3 questions of procedures for preventing further occupational hearning loss by an employee whenever such an event has been identified(component 6), and 1 question of recording keeping(component 7), thus total numbers of questions was 46. The numbers of statistially significant difference(p<0.05) between two groups were 2(25.0%) among 8 questions of component 3, 10(71.4%) among 14 questions of component 4, 3(33.3%) among 8 questions of component 5, 2(6.7%) among 3 questions of component 6, and 17(37.0%) among total 46 questions of questionnaire. Above results showed that the level of HCP acceptance in group I was lower than in group II. Thus employer's understanding about HCP should be precede for the effective hearing conservation program of employee and the adequate hearing protector, training and education, baseline and annual audiometry, and procedures for preventing further occupational hearning loss for hearing conservation would be more emphasized.

  • PDF

Pan-serotype reverse transcription loop-mediated isothermal amplification (RT-LAMP) for the rapid detection of foot-and-mouth disease virus (구제역바이러스 신속진단을 위한 pan-serotype reverse transcription loop-mediated isothermal amplification (RT-LAMP) 진단법)

  • Lim, Da-Rae;Park, Yu-Ri;Park, Sun-Young;Kim, Hye-Ryung;Park, Min-Ji;Ku, Bok-Kyung;Nah, Jin-Ju;Ryoo, So-Yoon;Wee, Sung-Hwan;Jeon, Hyo-Sung;Kim, Ji-Jeong;Jeon, Bo-Young;Lee, Hyeong-Woo;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.1
    • /
    • pp.29-39
    • /
    • 2018
  • In this study, we developed a sensitive and specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid visual detection of foot-and-mouth disease virus (FMDV) circulated in Korea. The RT-LAMP was completed in 40 min at $62^{\circ}C$ and the results of the assay were directly detected by naked eye without any detection process. The assay specifically amplified all 7 serotypes of FMDV RNAs but not amplified other viral and cellular nucleic acids. The sensitivity of the RT-LAMP was $10^2$, $10^3$ and $10^3TCID_{50}/mL$ for serotype O, A and Asia 1 FMDV, respectively, which was comparable to conventional reverse transcription polymerase chain reaction (RT-PCR) and relatively lower than that of real time quantitative RT-PCR (qRT-PCR). Clinical evaluation of the RT-LAMP using different serotypes of Korean and foreign FMDV strains showed a 100% (35/35) agreement with the results of the RT-PCR and qRT-PCR. These results indicated that RT-LAMP assay developed in this study could be a valuable diagnostic method for FMDV monitoring and surveillance.

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Analysis of Physical, Chemical and Biological Parameters, Based on Long-Term Monitoring (2004 $\sim$ 2007), in Daejeon Stream (대전천 수계의 장기 모니터링 (2004$\sim$2007)에 의한 물리적, 화학적, 생물학적 평가 변수 분석)

  • Lee, Min-Jung;Choi, Ji-Woong;Kim, Hyun-Mac;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.3
    • /
    • pp.364-373
    • /
    • 2009
  • We evaluated stream health, based on integrative approaches of qualitative habitat evaluation index (QHEI), chemical water quality and the index of biological integrity (IBI) using fish assemblages in Daejeon Stream during August 2004 - October 2007. The QHEI values in this study averaged 78.2 (n=28, range: 47$\sim$124), indicating "fair" condition based on the criteria of US EPA (1993). The highest value was in the headwater site (S1) that was 112 (good), whereas the value in S3, mid and downstream was SS (fair-poor) that was the lowest owing to a disturbance on the bed and an artificial bank. Concentrations of chemical parameters such as BOD, TP and conductivity increased from the upstream to the downstream due to higher inputs of organic matters and nutrients from the urban area. Conductivity and TP showed a dilution of stream water by rainwater during summer monsoon. Analysis of fish compositions showed that total number of species was 24 and Zacco platypus was predominated (82%). The mean IBI was 17 (range: 12$\sim$30) during four years and the IBI values also decreased from S1 to S4. These results indicated that ecological health was degradated distinctly as the stream goes down through the city-center. We concluded that Daejeon Stream running through the city are influenced by chemical impact such as an influx of domestic sewage as well as the quality of habitat.

Evaluation of the Potential Human Health Risk Associated with the Microcystin Bioaccumulation in the Freshwater Fish from Lake Yeongcheon and Lake Daecheong (영천호와 대청호에서 담수어류의 microcystin 농축에 따른 인체 건강위해성 평가)

  • Lee, Kyung-Lak;Jheong, Weon-Hwa;Kang, Young-Hoon;Kim, Han-Soon
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.3
    • /
    • pp.331-339
    • /
    • 2009
  • This study evaluated the potential human health risk on the basis of the level of bioaccumulation and EDI (Estimated Daily Intake) of microcystin-LR, one of hepatotoxic, in organs, including liver, muscle, viscera and gill, of fish from Lake Yeongeheon and Lake Daecheong when the cyanobacterial water-blooms broke out. The result has confirmed that Carassius cuvieri from Lake Yeongcheon contains higher level of microcystin-LR in its organs including liver. In Lake Daecheong, omnivorous Hemibarbus labeo and phytoplanktivorous Carassius cuvieri have shown high microcystin-LR level on average, especially higher for viscera, and Carassius cuvieri has appeared to contain higher level of microcystin-LR in the liver and the gill compared with other species. As a result of comparison between EDI of microcystin-LR from each organs and TDI (Tolerable Daily Intake) of WHO (Chorus and Bartram, 1999) to evaluate human health risk, the EDI levels from Carassius cuvieri's organs except museles have exceeded TDI level at the both lakes. Consequently, the study has proved that microcystin was bioaccumulated in the various parts of fish, and it can be ingested by human resulting in risking human health. Continuous monitoring and reducing consumption of fish, especially Carassius cuvieri, during the cyanobacterial water-blooming period will be needed to protect human health.

Accuracy Evaluation of Non-prism Total Station for Topographic Surveying (지형측량을 위한 무 프리즘 토털스테이션 정확도 평가)

  • Seo, Dong-Ju
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.5
    • /
    • pp.433-441
    • /
    • 2006
  • With a development of electrical technology in recent, it is possible to measure distance without direct contact to object using laser which launched at instrument and reflect from object. Furthermore, the advent of non prism total station brought the increment of application in many fields including not only road, airport, and harbors but also measurement and monitoring of structural displacement in construction fields. In this study, therefore, to evaluate accuracy of non prism total station, accuracy was analyzed by measuring certain distance which classified by both certain materials and angle of reflection. By this method, the derived values were applied to topographical survey for the efficient applicability. According to a study, result value of non prism total station was satisfBctory regardless of material when the angle of reflection was 90 degrees. RMSE increased when the angle of reflection are gradually increased to acute angle. In result of regression analysis using certain distance which classified by both materials and angles of reflection, there is relationship between distance and angle of reflection, but material has no relevance to the result value. When carrying out general topographical survey, proper application of non prism total station will go far conducting safe and prompt survey at the dangerous site such a road which have lots of traffic flow and rock joint which have high angles of inclination.

The Performance of Ictal Brain SPECT Localizing for Epileptogenic Zone in Neocortical Epilepsy (신피질성 간질에서 발작기 $^{99m}Tc$-HMPAO 뇌혈류 SPECT의 간질병소 국소화 성능)

  • Kim, Eun-Sil;Lee, Dong-Soo;Hyun, In-Young;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Sang-Kun;Chang, Kee-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.445-450
    • /
    • 1995
  • The epileptogenic zones should be localized precisely before surgical resection of these zones in intractable epilepsy. The localization is more difficult in patients with neocortical epilepsy than in patients with temporal lobe epilepsy. This study aimed at evaluation of the usefulness of ictal brain perfusion SPECT for the localization of epileptogenic zones in neocortical epilepsy. We compared the performance of ictal SPECT with MRI referring to ictal scalp electroencephalography(sEEG). Ictal $^{99m}Tc$-HMPAO SPECT were done in twenty-one patients. Ictal EEG were also obtained during video monitoring. MRI were reviewd. According to the ictal sEEG and semiology, 8 patients were frontal lobe epilepsy, 7 patients were lateral temporal lobe epilepsy, 2 patients were parietal lobe epilepsy, and 4 patients were occipital lobe epilepsy. Ictal SPECT showed hyperperfusion in 14 patients(67%) in the zones which were suspected to be epileptogenic according to ictal EEG and semiology. MRI found morphologic abnormalities in 9 patients(43%). Among the 12 patients, in whom no epileptogenic zones were revealed by MRI, ictal SPECT found zones of hyperperfusion concordant with ictal SEEG in 9 patients(75%). However, no zones of hyperperfusion were found in 4 among 9 patients who were found to have cerebromalacia, abnormal calcification and migration anomaly in MRI. We thought that ictal SPECT was useful for localization of epileptogenic zones in neocortical epilepsy and especially in patients with negative findings in MRI.

  • PDF

Availability Evaluation of TOC as the Environmental Standard - Survey of Lakes in Nakdong River Basin - (환경기준으로서의 TOC에 대한 활용성 평가 - 낙동강수계 호소를 대상으로 -)

  • Choi, Byoungwoo;Kang, Meea
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.173-180
    • /
    • 2018
  • The utilization of TOC(Total organic carbon), a new environmental standard, was evaluated for 30 lakes in the Nakdong River Basin, which is used for drinking and agricultural usage. The active use of water resources begins with securing satisfactory water quality. Since this allows people and nature to maintain stability of quality, water quality standards are being tightened to ensure good water quality. In order to improve the pollution level of organic matter in lakes in the living environment, it is important to use the appropriate organic substance index. The relationship between the newly introduced TOC and the existing COD(Chemical oxygen demand) in the targeted lake was positively correlated with the possibility of replacing the TOC with COD. However, the environmental grade standard using TOC is better than the environmental grade standard using COD, so it has the same effect as that of the grade of water quality using TOC as an organic substance factor. This indicates the limitation of TOC to directly replace existing COD when trying to determine or improve the quality level using organic indicators of lakes. Therefore, in order to secure the qualitative safety of the lake, it is required to strengthen environmental standards of TOC in terms of water quality grade. In addition, the correlation between TOC and COD shows a great difference depending on the utilization characteristics of the lake. This requires clear scientific identification, and it requires continuous monitoring of COD that has been used to accumulate indicators of lake organic matter.

Evaluation of Coastal Urban Flood Warning Alarm Rule Using Real Hydrologic Monitoring Observation (실 수문관측을 통한 해안도시홍수 경보발령기준안 검정)

  • Shin, Hyun-Suk;Kang, Doo-Kee;Kim, Hong-Tae;Song, Young-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.336-340
    • /
    • 2007
  • 국내 산업 및 기능적 측면에서 중추역할을 수행하고 있는 부산 울산 인천 등 전체 도시의 40%를 이루고 있는 해안도시들이 하천범람과 같은 홍수피해, 해일피해 등에 대한 체계적인 대비가 전무한 실정으로서 본 연구는 모형화 기법을 이용하여 해안도시홍수 경보발령 기준안을 도출하고 이를 실 수문관측 자료를 이용한 검정을 통해 경보발령 기준안의 문제점을 파악하여 그 개선방향을 제시하였다. 대상유역은 대표적 해안도시하천의 특성을 지니고 있는 부산시 온천천유역으로 강우-수위 관측 모니터링 시스템을 구축, 운영을 통해 10분 간격 강우 및 수위 자료를 구축하였으며, 수위 자료는 수위 유량 관계곡선을 이용하여 유량으로 환산하였다. 미계측 상태에서의 수리 수문 모형화를 통해 도출된 경보발령기준안에 대한 평가 및 문제점 도출을 위해 본 연구는 유역내 실시간 수문관측을 통해 얻은 강우 및 유출 특성 자료를 이용하였다. 대상 유역내 경보발령 지점인 세병교 지점의 20분 누가기준 경보발령 기준우량은 한계수위 $H_{c1},\;H_{c2},\;H_{c4}$인 경우 각각 4mm, 5mm, 6mm로서 20개월 동안 이러한 기준을 이용하여 관측된 강우사상 중 경보발령 기준안의 평가가 가능한 26개의 강우사상을 분류할 수 있었다. 그 결과 약 60%의 강우사상(case_1)이 성공한 경보발령 기준우량 임을 관측할 수 있었으며 이러한 발생강우에 대해 $20{\sim}150$분의 대피여유시간을 확보할 수 있었다. 그러나. 경보발령에 실패한 40%의 강우사상은 발생 강우의 총강우량이 대체적으로 적은 경우 및 지속기간 동안 경보발령기준에 준하는 강우를 발생하였으나 수위에 영향이 미비하여 한계수위에 도달하지 못한 경우(case_2), 20분 누가강우는 기준에 도달하지 않았으나 강우 지속시간이 길어 이미 선행강우로 인해 경보발령 이전에 한계수위를 넘어서는 경우(case_3)로서 분석되었다. 이러한 실패한 경보발령의 경우에 대한 원인분석 결과, 기존의 모형화를 통해 고려되지 못하였던 해안도시 홍수의 특성 중 총강우량에 대한 고려, 선행강우 여부 및 강우 지속시간, 지속시간 내 강우집중도 그리고 선정지점 내 조위의 영향과 유역내 합류식 하수관거 시스템의 영향 등 자연유역과는 다른 다소 복잡한 요소를 고려한 해안도시홍수 경보발령 기준에 대한 개선이 필요함을 확인할 수 있었다.

  • PDF