• Title/Summary/Keyword: Monitoring-Evaluation

Search Result 2,531, Processing Time 0.037 seconds

Site Monitoring and investigation plan for LILW disposal (방사성폐기물 처분장 부지감시 계획)

  • Baek, Seung-Jong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.369-385
    • /
    • 2008
  • The purpose of site monitoring and investigation is to offer the basic data for performance assessment and design of low- and intermediate-level radioactive waste(LILW) disposal facility by monitoring variations of main site properties continually in the stage of pre-operation, operation and post-closure. Main contents of site monitoring are as follows. In the stage of pre-operation, suitability evaluation for disposal facility and monitoring for constructing and operating disposal facility are performed. In the operation period, monitoring is performed including surroundings to research the influence to environment with operating disposal facility and operate safely and efficiently. In the post-closure period, monitoring about major site properties is performed to prevent the effect of radioactive waste from disposal facility and to secure long-term safety.

  • PDF

A Development of the Service Evaluation Criteria for the Expressway Service Areas on the Side of Users (이용자측면의 고속도로 휴게소 서비스 평가지표 개발)

  • Won, Jaimu;Jin, Wonyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5D
    • /
    • pp.421-427
    • /
    • 2012
  • This study develops the evaluation model which is for assessing on the side of users in expressway service areas, and researchers apply this study for monitoring expressway service areas by routes. The direction of development on Evaluation Criteria is all about on the side of necessity of rest area users, the reflection of current conditions, the construction of total evaluation criteria, and the examination of connecting study with current study. After that, this study examines previous evaluation criterias and researchers will select the primary provision of evaluation through FGI, and they derive the final evaluation criteria throughout the verification of suitability on Evaluation Criteria. Throughout AHP analysis which is a professional survey system of users, researchers dereive on the side of facilities, on the side of environments facilities, on the side of position, and on the side of services in order by the weightings. As you can see in this study, this study also considers quantitative and qualitative factors together, and it allows to evaluate conditions of rest areas. In addition, this study can be a primary study for suggesting the ways of improvements of rest areas by using Spider Map and for monitoring future study.

Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial (PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상)

  • Cheol-Gu Park;Sang-Ki Choi;Seong-Geun Jo;Kwon-Min Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • This study is a performance evaluation of a blood sugar monitoring system that combines a PPG sensor, which is an evaluation device for blood glucose monitoring, and a DNN algorithm when monitoring capillary blood glucose. The study is a researcher-led clinical trial conducted on participants from September 2023 to November 2023. PPG-BGMS compared predicted blood sugar levels for evaluation using 1-minute heart rate and heart rate variability information and the DNN prediction algorithm with capillary blood glucose levels measured with a blood glucose meter of the standard personal blood sugar management system. Of the 100 participants, 50 had type 2 diabetes (T2DM), and the average age was 67 years (range, 28 to 89 years). It was found that 100% of the predicted blood sugar level of PPG-BGMS was distributed in the A+B area of the Clarke error grid and Parker(Consensus) error grid. The MARD value of PPG-BGMS predicted blood glucose is 5.3 ± 4.0%. Consequentially, the non-blood-based PPG-BGMS was found to be non-inferior to the instantaneous blood sugar level of the clinical standard blood-based personal blood glucose measurement system.

Evaluation of Total Parenteral Nutrition in Tertiary Hospital (3차병원에서의 TPN 사용의 적정성 점토)

  • Min, Kyoung A;Sohn, Ki Ho;Suh, Ok Kyung;Choi, Kyung Eob
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.1
    • /
    • pp.35-46
    • /
    • 1998
  • A retrospective study was conducted to evaluate the appropriateness of total parenteral nutrition (TPN) for 200 hospitalized adult patients in Samsung Medical Center from January 1st in 1995 to June 31st in 1997. Standard criteria were modified and determined from those stated by AJHP (American Journal of Health System Pharmacy) and ASPEN (American Society of Parenteral and Enteral Nutrition). The justification for indications was appropriate in $35\%,\;44\%,\;and\;32\%$ of the patient's in 1995, 1996, and 1997, respectively, without significant improvement over the last two and half years. Before and during the administration of TPN, several monitoring indicators were well documented, and monitoring frequencies were increased over two and half years period. However, the majority of the monitoring indicators were not found in the standard criteria range of $90\%$. The monitoring indicators for electrolyte balance, $PO_4$ and Mg, were not measured appropriately and resulted in the complications which could have been prevented. The indicator for lipid tolerance, triglyceride and the indicator for hemorrhagic incidence, prothrombin time (PT), were not well documented in comparison with other indicators. The indicators for the improvement in nutritional status, albumin and total protein, were appropriate in $90\%$ of the patients. Determination of TPN formula was based on the laboratory data and chart reviews, and it was appropriate in $98\%$. But the administration of lipid and vitamin K for the prevention of essential fatty acid deficiency and hemorrhage, respectively, was not carried out appropriately when the administration of TPN was prolonged, lasting more than 7 days. When a patient returned to oral or enteral feeding, TPN was terminated. However, increase in albumin level or weight was rarely observed. In conclusion, healthcare professionals should all work as a team and active participation to provide optimized nutrition support for partners.

  • PDF

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.

Process Evaluation of a Mobile Weight Loss Intervention for Truck Drivers

  • Wipfli, Brad;Hanson, Ginger;Anger, Kent;Elliot, Diane L.;Bodner, Todd;Stevens, Victor;Olson, Ryan
    • Safety and Health at Work
    • /
    • v.10 no.1
    • /
    • pp.95-102
    • /
    • 2019
  • Background: In a cluster-randomized trial, the Safety and Health Involvement For Truck drivers intervention produced statistically significant and medically meaningful weight loss at 6 months (-3.31 kg between-group difference). The current manuscript evaluates the relative impact of intervention components on study outcomes among participants in the intervention condition who reported for a post-intervention health assessment (n = 134) to encourage the adoption of effective tactics and inform future replications, tailoring, and enhancements. Methods: The Safety and Health Involvement For Truck drivers intervention was implemented in a Web-based computer and smartphone-accessible format and included a group weight loss competition and body weight and behavioral self-monitoring with feedback, computer-based training, and motivational interviewing. Indices were calculated to reflect engagement patterns for these components, and generalized linear models quantified predictive relationships between participation in intervention components and outcomes. Results: Participants who completed the full program-defined dose of the intervention had significantly greater weight loss than those who did not. Behavioral self-monitoring, computer-based training, and health coaching were significant predictors of dietary changes, whereas behavioral and body weight self-monitoring was the only significant predictor of changes in physical activity. Behavioral and body weight self-monitoring was the strongest predictor of weight loss. Conclusion: Web-based self-monitoring of body weight and health behaviors was a particularly impactful tactic in our mobile health intervention. Findings advance the science of behavior change in mobile health intervention delivery and inform the development of health programs for dispersed populations.

Estimating the Number of Target Workplaces for Work Environment Monitoring using Survey Data among Manufacturing Businesses with More than Five Employees in 2016 (5인이상 제조업에서 설문조사를 통한 작업환경측정 대상 사업장의 규모 추정)

  • Bahk, Jinwook;Kim, Seung-Won;Yang, Seon-Hee;Ryu, Hyang Woo;Kim, Eun-A
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.166-174
    • /
    • 2018
  • Objectives: This study aimed to estimate the number and proportion of target workplaces for work environment monitoring and evaluate the implementation rate of work environment monitoring. Methods: A questionnaire survey was conducted by the Ministry of Employment and Labor between March and May 2017 among 96,295 manufacturing businesses with more than five employees. The response rate was 17.8%. Estimates of the number and proportion of target workplaces for work environment monitoring were calculated as follows: number of workplaces where work environment monitoring was performed in 2016 + exposure rate based on the questionnaire * number of workplaces where work environment monitoring was not conducted. Results: Of the 150,655 total manufacturing businesses with more than five employees, 63,146 are estimated to be subject to work environment monitoring, which accounted for 41.9% of the workplaces. It is estimated that 73.3% of the target workplaces performed work environment monitoring. The number of workers exposed to hazardous substances is estimated to be about 0.7~1.2 million. Conclusions: Information on the distribution of workplaces subject to work environment monitoring and the rate of implementation can be used as baseline information for management and evaluation of the effectiveness of the work environment monitoring system.

Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery

  • Seungji Hyun;Seungwook Lee;Yu Sun Hong;Sang-hyun Lim;Do Jung Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.205-212
    • /
    • 2024
  • Background: Postoperative atrial fibrillation (A-fib) is a serious complication of cardiac surgery that is associated with increased mortality and morbidity. Traditional 24-hour Holter monitors have limitations, which have prompted the development of innovative wearable electrocardiogram (ECG) monitoring devices. This study assessed a patch-type wearable ECG device (MobiCARE-MC100) for monitoring A-fib in patients undergoing cardiac surgery and compared it with 24-hour Holter ECG monitoring. Methods: This was a single-center, prospective, investigator-initiated cohort study that included 39 patients who underwent cardiac surgery between July 2021 and June 2022. Patients underwent simultaneous monitoring with both conventional Holter and patchtype ECG devices for 24 hours. The Holter device was then removed, and patch-type monitoring continued for an additional 48 hours, to determine whether extended monitoring provided benefits in the detection of A-fib. Results: This 72-hour ECG monitoring study included 39 patients, with an average age of 62.2 years, comprising 29 men (74.4%) and 10 women (25.6%). In the initial 24 hours, both monitoring techniques identified the same number of paroxysmal A-fib in 7 out of 39 patients. After 24 hours of monitoring, during the additional 48-hour assessment using the patch-type ECG device, an increase in A-fib burden (9%→38%) was observed in 1 patient. Most patients reported no significant discomfort while using the MobiCARE device. Conclusion: In patients who underwent cardiac surgery, the mobiCARE device demonstrated diagnostic accuracy comparable to that of the conventional Holter monitoring system.

Study on Prediction of Drill Breakage using Spindle and Z-axis Motor Currents (주축 및 Z축 모터전류를 이용한 드릴파손 예측에 관한 연구)

  • Kim, Hwa-Young;Ahn, Jung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.101-108
    • /
    • 1999
  • A reliable and practical monitoring of drill breakage is a crucial technique in automatic machining system. In this study, a real-time monitoring system was developed to predict drill breakage using both spindle and z-axis motor current. Drill breakage is monitored by detecting the level of residual motor current which is obtained through the moving average filter algorithm. The residual exhibits a feature of sharp decrease just before drill breakage. Therefore, drill breakage can be predicted by detecting this characteristic of residual component. Z-axis motor current is better to predict the drill breakage than spindle motor current, because the former is faster in response than the latter when drill breakage is occurred. The evaluation experiments have shown that the developed monitoring system works very well.

  • PDF

Sn$O_2$ Ceramic Gas Sensor for VOC Contaminated Soil Gas Monitoring (VOC 함유 토양가스 모니터링을 위한 Sn$O_2$ 세라믹 가스센서의 반응특성 연구)

  • 최관영;조현정;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.125-128
    • /
    • 2000
  • Recently, development of advanced soil monitoring technology has became essential for effective site remediation. Soil gas evaluation is simple and powerful technology which can reduce the environmental impact during the survey of VOC contaminated area. In this research, the feasibility test of SnO$_2$ceramic gas sensor is conducted to improve soil gas measurement technology. As a result, it is successfully proved that this gas sensor has an possibility for soil gas monitoring.

  • PDF