• 제목/요약/키워드: Monitoring station

검색결과 784건 처리시간 0.027초

Performance indicator of the atmospheric corrosion monitor and concrete corrosion sensors in Kuwait field research station

  • Husain, A.;Al-Bahar, Suad Kh.;Salam, Safaa A. Abdul
    • Smart Structures and Systems
    • /
    • 제17권6호
    • /
    • pp.981-994
    • /
    • 2016
  • Two field research stations based upon atmospheric corrosivity monitoring combined with reinforced concrete corrosion rate sensors have been established in Kuwait. This was established for the purpose of remote monitoring of building materials performance for concrete under Kuwait atmospheric environment. The two field research sites for concrete have been based upon an outcome from a research investigation intended for monitoring the atmospheric corrosivity from weathering station distributed in eight areas, and in different regions in Kuwait. Data on corrosivity measurements are essential for the development of specification of an optimized corrosion resistance system for reinforced concrete manufactured products. This study aims to optimize, characterize, and utilize long-term concrete structural health monitoring through on line corrosion measurement and to determine the feasibility and viability of the integrated anode ladder corrosion sensors embedded in concrete. The atmospheric corrosivity categories supported with GSM remote data acquisition system from eight corrosion monitoring stations at different regions in Kuwait are being classified according to standard ISO 9223. The two nominated field sites where based upon time of wetness and bimetallic corrosion rate from atmospheric data where metals and rebar's concrete are likely to be used. Eight concrete blocks with embeddable anodic ladder corrosion sensors were placed in the atmospheric zone adjacent to the sea shore at KISR site. The anodic ladder corrosion rate sensors for concrete were installed to provide an early warning system on prediction of the corrosion propagation and on developing new insights on the long-term durability performance and repair of concrete structures to lower labor cost. The results show the atmospheric corrosivity data of the environment and the feasibility of data retrieval of the corrosion potential of concrete from the embeddable sets of anodic ladder corrosion sensors.

가속도 응답을 이용한 이상치 해석 기반 역사 구조 건전성 평가 기법 개발 (Structural Health Monitoring Methodology based on Outlier Analysis using Acceleration of Subway Stations)

  • 신정열;안태기;이창길;박승희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.281-286
    • /
    • 2011
  • Station structures, one of important infrastructures, which have been being operated since the 1970s, are especially vulnerable to even the medium-level earthquake and they could be damaged by long-term internal or external vibrations such as ambient vibrations. Recently, much attention has been paid to real-time monitoring of the fatal defect or long-term deterioration of civil infrastructures to ensure their safety and adequate performance throughout their life span. In this study, a structural health monitoring methodology using acceleration responses is proposed to evaluate the health-state of the station structures and to detect initial damage-stage. A damage index is developed using the acceleration data and it is applied to outlier analysis, one of unsupervised learning based pattern recognition methods. A threshold value for the outlier analysis is determined based on confidence level of the probabilistic distribution of the acceleration data. The probabilistic distribution is selected according to the feature of the collected data.

  • PDF

대형.고밀도역 역내 열차 경합 검지 및 해소를 위한 수리 모형 및 해법 (An Algorithm for train conflict detection and resolution occurring in large station with high density traffic)

  • 박범환;김경민;홍순흠;김영훈;안진;이영수;하승태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1466-1474
    • /
    • 2007
  • In large station with high density traffic, trains is hardly controlled by CTC but by station dispatcher because CTC has difficulties in monitoring all states of affairs happening within the station such as departs and arrivals of many trains from different lines and shunting trains between yards and platforms, etc. Therefore station dispatcher has to make quick decision about how to schedule all trains including trains to arrive and depart before long. And such decisions become harder when an unexpected delay occurs. This study suggests a mathematical model and algorithm about how to detect in advance and resolve efficiently the conflicts occurring within a station and it will be shown how to reduce delay using our approach by means of analysing the schedule of ChyungRyangRi station.

  • PDF

Web Information Systems for Safety and Health Monitoring in Subway Stations

  • Choi, Gi-Heung
    • International Journal of Safety
    • /
    • 제8권1호
    • /
    • pp.10-13
    • /
    • 2009
  • In this study, a framework for web-based information system in VDN environment for safety and health monitoring in subway stations is suggested. Since physical variables that describing safety and health need to be closely monitored in multiple locations in subway stations, concept of distributed monitoring network using wireless media needs to be implemented. Connecting remote wireless sensor network and device (LonWorks) networks to the IP network based on the concept of VDN can provide a powerful, integrated and distributed monitoring performance, making a web-based information system possible.

Identification of structural displacements utilizing concurrent robotic total station and GNSS measurements

  • Pehlivan, Huseyin
    • Smart Structures and Systems
    • /
    • 제30권4호
    • /
    • pp.411-420
    • /
    • 2022
  • Monitoring large structures is a significant issue involving public health on which new studies are constantly carried out. Although the Global Navigation Satellite System (GNSS) is the most preferable method for measuring structural displacements, total stations, one of the classical geodetic instruments, are the first devices that come to mind in cases that require complementary usage and auxiliary measurement methods. In this study, the relative displacements of the structural movements of a tower were determined using robotic total stations (RTS) and GNSS. Two GNSS receivers and two RTS observations were carried out simultaneously for 10 hours under normal weather conditions. The spectral analysis of the GNSS data was performed using fast Fourier transform (FFT), and while the dominant modal frequencies were determined, the total station data were balanced with the least-squares technique, and the position and position errors were calculated for each measurement epoch. It has been observed that low-frequency structural movements can be determined by both methods. This result shows that total station measurements are a helpful alternative method for monitoring large structures in situations where measurements are not possible due to the basic handicaps of GNSS or where it is necessary to determine displacements with short observations.

Wet Station 모니터링을 위한 제어 모듈의 설계 및 구현 (A Study on Design and Implementation of Control Module for Wet Station Monitoring)

  • 한광록;황미자
    • 한국정보처리학회논문지
    • /
    • 제5권7호
    • /
    • pp.1813-1828
    • /
    • 1998
  • 본 논문에서는 기능별로 태스크를 설계하고 프로세스간 통신을 위하여 공유 메모리를 사용하여 wet station 모니터링 시스템을 구현한다. 롯트라는 반도체 웨이퍼 단위를 처리하기 위하여 레시피 명령을 설계하고 이 레시피에 의한 롯트의 배치 처리 과정을 모니터링하는 방법에 대하여 논한다. 설계된 태스크 및 레시피, 공유 메모리를 구현하여 실제 장비에 적용한 결과 각 태스크들이 레시피 명령에 따라 공유 메모리를 매개로 하여 배치 작업을 진행하였고 그 과정을 그래픽 화면을 통해 시각적으로 모니터링 할 수 있었다.

  • PDF

2012-2016년 모니터링 자료를 이용한 낙동강 지류·지천 수질 특성 분석 (Water Quality Analysis in Nakdong River Tributaries Using 2012-2016 Monitoring Data)

  • 손영규;나승민;임태효;김상훈
    • 한국물환경학회지
    • /
    • 제33권6호
    • /
    • pp.680-688
    • /
    • 2017
  • Water quality monitoring for flow rates and BOD/COD/T-N/T-P/SS/TOC concentrations has been conducted in Nakdong river tributaries since 2011. In this study concentrations and loading rates of BOD, T-P, and TOC were analyzed to evaluate water quality monitoring stations using accumulated data at 206 tributary monitoring stations in Nakdong river 2012 ~ 2016. Average concentration ranges for 206 monitoring stations were 0.3 ~ 6.4 mg/L, 0.025 ~ 1.562 mg/L, and 0.6 ~ 10.7 mg/L for BOD, T-P, and TOC, respectively. Additionally, average loading rate ranges were 0.96 ~ 46,040 kg/d, 0.087 ~ 1,834 kg/d, and 1.51 ~ 80,425 kg/d for BOD, T-P, and TOC, respectively. Average concentration for BOD, T-P, and TOC at each monitoring station was evaluated using ambient water quality standards of rivers and water quality regulation level for medium-sized management areas. Average loading rate and specific loading rate (loading rate/drainage basin area) for BOD, T-P, and TOC at each monitoring station was considered to evaluate monitoring stations using suggested classification (BOD, TOC: -1, 1 ~ 10, 10 ~ 100, 100 ~ 1,000, and 1,000 ~ kg/d; T-P: -0.1. 0.1 ~ 1, 1 ~ 10, 10 ~ 100, and 100 ~ kg/d) Using results of this study, various water quality status maps were provided, and three evaluation methods were suggested to determine priority monitoring stations in Nakdong river for rational water quality control and tributaries basin management.

항공기소음 자동측정국 감시효율에 대한 연구 (A Study on Monitoring Efficiency of the Aircraft Noise Monitoring Stations)

  • 손정곤;정우홍;황민기;권현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.423-428
    • /
    • 2008
  • The monitoring efficiency of the aircraft noise monitoring stations is decided to the reference noise level and the infringement of each monitoring stations. We are calculate the monitoring efficiency of three noise monitoring stations among twelve in the vicinity of Gimpo Int'l Airport. As a result, the monitoring efficiency shows that the noise monitoring stations #3,#5 and #6 are 14.3%, 18.5% and 29.3% respectively, #6 which is underneath the flight track is higher efficiency than another two stations.

  • PDF

기준점 측량을 활용한 광파기 기반 댐 제체 변위 계측 신뢰도 향상 (Improving Reliabilities of Dam Displacement based on Monitoring Given Points by Total Station)

  • 강기천;김봉재;홍석우;임연출;김지성
    • 한국지반신소재학회논문집
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 댐 변위 모니터링은 댐의 안전성을 위협하는 영향을 파악하여 댐과 관련된 붕괴사고를 사전에 방지하고, 댐을 안전하게 운영하고 유지 관리하는데 중요한 항목으로 사용되고 있다. 하지만, 기존 변위계측 분석 결과 원인불명의 변위가 발생하여 정확한 댐 거동 해석을 저해하고 있다. 본 연구에서는 광파기(Total Station) 기반 댐의 변위계측의 신뢰성 개선을 위해 그 보정방법을 제안하였다. 현재까지의 광파기에 의한 변형 모니터링은 기준점(2~3개소)과 광파기가 설치된 기계점 위치를 초기에 측량하여 불변으로 간주하였고, 측량과정에서 중요한 변위 산정요소가 되는 기준 수평 수직각은 고려하지 않고 측량을 실시하였다. 본 연구에서는 실제 댐 변위 계측시 기준점 측량을 통해 광파기의 위치 변화 및 기준 수평 수직각의 변화를 관측하였다. 그 결과 오차발생의 가장 큰 원인은 광파기 위치 변화와 댐 변위량 계산에 중요한 항목인 기준 수평 및 수직각임이 밝혀졌다. 또한, 이를 보정한 결과 최대 변위 20mm에서 약 ${\pm}5mm$로 감소하였다.

차량위치추적 시스템을 위한 다중 기준국 Inverted DGPS 시스템 (Multi-Reference Inverted DGPS System for Automatic Vehicle Location System)

  • 홍진석;한승재;지규인;이영재;이장규;최홍석
    • 제어로봇시스템학회논문지
    • /
    • 제5권1호
    • /
    • pp.79-87
    • /
    • 1999
  • For its simplicity and cost effectiveness in implementation, the Inverted DGPS is well suited for some specific applications like automatic vehicle location systems, where the monitoring station needs accurate position of the vehicles in the street. In the Inverted DGPS, the user sends its GPS position and associated satellite informations to the reference station, and the corrections are made at the reference station to get differentially corrected user position. A fundamental requirement in IDGPS is that the user and the reference station must use the same satellites when the corrections are made. But in practice, it is not often satisfied. Inverted DGPS is also suffered from performance degradation as the baseline become large like DGPS. IDGPS system using multi-reference station can resolve this problem. In this paper a simple multi-reference IDGPS algorithm is proposed and some experiments and analysis are peformed. Experiment results show that IDGPS can achieve the positioning performance as accurate as the DGPS can provide.

  • PDF