• Title/Summary/Keyword: Monitoring simulator

Search Result 205, Processing Time 0.039 seconds

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

Development of An Actuator-Based Blood Pressure Simulator for Automatic Blood Pressure Monitor (자동혈압계 점검을 위한 액추에이터 기반의 혈압 시뮬레이터 개발)

  • Soo Hong Kim;Seung Jun Lee;Mun Hyeok Lim;Hye Min Park;Min Seok Gang;Gun Ho Kim;Kyoung Won Nam
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.49-55
    • /
    • 2024
  • Accurate measurement of blood pressure is essential for classifying an individual's disease, identifying blood pressure-related risks, and managing health. Due to the environmental and health hazards of mercury sphygmomanometers, automatic sphygmomanometers using the oscillometric method are widely used in hospitals as well as in general homes, and have established themselves as a practical standard sphygmomanometer. In this study, we developed a blood pressure simulator using an actuator that provides simulated pressure to an automatic blood pressure cuff. The developed blood pressure simulator adopts an arm-shaped cylindrical shape similar to the situation in which a person measures blood pressure with an automatic blood pressure monitor, and implements a method of transmitting pressure to the cuff using a pressure plate. Accuracy was evaluated through the mean and standard deviation of the difference with the commercialized blood pressure simulator BP PUMP 2, and reproducibility was confirmed using two automatic blood pressure monitors. The developed blood pressure simulator enables automatic blood pressure monitoring in a simple manner and also meets the evaluation standards for accuracy and reproducibility. In the future, as a standardized blood pressure simulator, it is expected to be of great help in evaluating and verifying the performance of automatic blood pressure monitors by supplementing precise hardware and software and building a blood pressure database.

Development of Hardware Simulator for Operation Analysis of DC Microgrid (DC 마이크로그리드의 동작분석을 위한 하드웨어 시뮬레이터 개발)

  • Lee, Ji-Heon;Kim, Won-Yong;Kim, Jong-Won;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.577-586
    • /
    • 2011
  • This paper describes the development of hardware simulator for the operation analysis of DC microgrid. The hardware simulator consists of several distributed power sources such as a wind power generation, solar power and fuel cell, and two energy storages such as a supercapacitor and battery. The main controller which performs a role of energy management and state monitoring is connected with the local controller in each power source and storage through ethernet-based communication link. The developed hardware simulator can be utilized to analyze the performance DC microgrid with practical manner.

Power Quality Monitoring Algorithm Using the Protective Relay (보호계전기를 이용한 전기 품질 감시 기법 연구)

  • Choi In. S.;Lee Kang. S.;Choi Myeon. S.;Lim Seong. I.;Lee Seung. J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.581-588
    • /
    • 2004
  • Power qualify monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. This paper was studied on using data of the protective relay by Power Quality Monitor. This paper was proposed the wave storage condition and monitoring clauses of the protective relay as a power quality monitoring device. The protective relay will have problem to save data for PQM analysis because the protective relay memory is limited. Therefore this paper was proposed new a data compression of data got from the protective relay. This method is wave compression comparison algorithm using the DFT. The compression rate is higher than any other established method. This method can be real time storage. This algorithm is verified using the comparison among other compression rate and proved by Real Time Digital Simulator (RTDS).

Real Time Driver's Respiration Monitoring (실시간 운전자 호흡 모니터링)

  • Park, Jaehee;Kim, Jaewoo;Lee, Jae-Cheon
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.142-147
    • /
    • 2014
  • Real time driver's respiration monitoring method for detecting driver's drowsiness is investigated. The sensor to obtain driver's respiration signal was a piezoelectric pressure sensor attached at the abdominal region of the seat belt. The resistance of the pressure sensor was changed according to the pressure applied to the seat belt due to the driver's respiration. Monitoring driver's respiration was carried out by driving on the virtual road in a driving simulator from Cheonan to Seoul and monitoring results were compared to the PELCLOS. Experiment results show that the driver's respiration signal can be used for detecting driver's drowsiness.

Development of a Web-Based Remote Monitoring System for Evaluating Degradation of Machine Tools Using ART2 (ART2 신경회로망을 이용한 공작기계의 웹기반 원격 성능저하 모니터링 시스템 개발)

  • Kim, Cho-Won;Choi, Kook-Jin;Jung, Sung-Hwan;Hong, Dae-Sun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.1
    • /
    • pp.42-49
    • /
    • 2009
  • This study proposes a web-based remote monitoring system for evaluating degradation of machine tools using ART2(Adaptive Resonance Theory 2) neural network. A number of studies on the monitoring of machine tools using neural networks have been reported. However, when normal condition is changed due to factors such as maintenance, tool change etc., or a new failure signal is generated, such algorithms need to be entirely retrained in order to accommodate the new signals. To cope with such problems, this study develops a remote monitoring system using ART2 in which new signals when required are simply added to the classes previously trained. This system can monitor degradation as well as failure of machine tools. To show the effectiveness of the proposed approach, the system is experimentally applied to monitoring a simulator similar to the main spindle of a machine tool, and the results show that the proposed system can be extended to monitoring of real industrial machine tools and equipment.

Design and Implementation of Warehouse Management System Simulator (창고관리시스템 시뮬레이터의 설계 및 구현)

  • Kim, Chi-Taek;Lee, Min-Soon;Lee, Byoung-Soo
    • Convergence Security Journal
    • /
    • v.8 no.4
    • /
    • pp.73-80
    • /
    • 2008
  • In this paper, we developed a WMS (Warehouse Management System) Simulator. There is no Simulator that supports optimized design for Warehouse, consider goods which storage in warehouse and using RFID and USN based on cable wireless network. Also, there is no tool for monitoring which decides delivery time with information about temperature, humidity and illumination, after goods are stocked into warehouse. In this paper, WMS Simulator Implements function of drawing a blueprint. The Simulator that can analyze moving information of Palette with RFID tags and the change about temperature, humidity and illumination is developed in this paper. Inventory accuracy, space equipment practical use, and decreasing of picking time, faulty storage and product loss by product processing ability elevation are expected by designing the way of operating of warehouse for most suitable use of system in physical distribution through these treatise.

  • PDF

Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator (파일럿 규모 모의관로에서 부식성 수질제어 효과와 부식지수 모니터링)

  • Kim, Do-Hwan;Kim, Yung-Jin;Son, Hee-Jong;Ryou, Dong-Choon;Ahn, Jun-Young;Kim, Cheolyong;Hwang, In-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.183-192
    • /
    • 2018
  • Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.

Development of Mobile Performance Management System Using Real-Time Monitoring Method (실시간 모니터링 기법을 이용한 모바일 성능 관리 시스템 개발)

  • Jeong, Taeg-Won;Lee, Chul-Han;Lee, Chong-Deuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1894-1902
    • /
    • 2009
  • As the spread of LBS(Location Based Service), MDT(Mobile Data Terminal) and PDA (Personal Digital Assistant) services using mobile terminals, various systems are under development to to manage the performance of these services. This paper describes a mobile performance management system which is implemented to test the performance of mobility between the user and the terminal or between the terminal and the mobile server automatically in the mobile-user field. The system has four modules: scenario management module, MDT monitoring, LBS monitoring, and PDA monitoring. The scenario management module manages the performance by monitoring all modules. The LBS monitoring module monitors LBS call attempt stage, call connecting stage, and LBS test for established connection. Thus, the LBS monitoring module manages the performance for every stage of the call. The MDT monitoring module monitors the performance according to the input command and the PDA monitoring module monitors according to the input from the set up and the execution menu.