• 제목/요약/키워드: Monitoring methodology

검색결과 656건 처리시간 0.026초

A Methodology of Automated Analysis and Qualitative Assessment of Legislation and Court Decisions

  • Trofimov, Egor;Metsker, Oleg;Kopanitsa, Georgy
    • International Journal of Computer Science & Network Security
    • /
    • 제22권11호
    • /
    • pp.229-235
    • /
    • 2022
  • This study aims to substantiate an interdisciplinary methodology for automated analysis and qualitative assessment of legislation and court decisions. The development of this kind of methodology will make it possible to fill a number of methodological gaps in various research areas, including law effectiveness assessment and legal monitoring. We have defined a methodology based on the interdisciplinary principles and tools. In general, it should be noted that even at the level of qualitative assessment made with the use of the methodology described above, the accumulation of knowledge about the relationship between legal objectives, indicators and computer methods of their identification can reduce the role of expert knowledge and subjective factor in the process of assessment, planning, forecasting and control over the state of legislation and law enforcement. Automation of intellectual processes becomes inevitable in a digital society, but, releasing experts from routine work, simultaneously reorients it to development of interdisciplinary methods and control over their application.

Study on Improving the Accuracy of Mobile Air Quality Monitoring Systems

  • Jong-Sun CHOI;Woo-Taeg KWON;Woo-Sik LEE
    • 웰빙융합연구
    • /
    • 제7권4호
    • /
    • pp.1-13
    • /
    • 2024
  • Purpose: The purpose of this study is to develop a highly accurate mobile air quality monitoring system suitable for use in various event-specific locations, such as fireworks festivals or construction sites. Research design, data and methodology: The study focuses on optimizing the selection and design of equipment for a mobile air quality monitoring system, aiming to reduce production costs and improve measurement accuracy. It includes a comparative analysis with existing Air Quality Monitoring Stations (AQMS) and enhances calibration methods to stabilize performance under various environmental conditions. This approach ensures a cost-effective, accurate, and efficient mobile air quality monitoring system. Results: By utilizing measurement data collected from various regions, further improvements can be made in the future to develop a more efficient and accurate mobile air quality monitoring system. The accuracy of the existing mobile air quality monitoring system has been enhanced through this study, making it applicable for measurements in various fields. Conclusions: With the growing concern about air pollution, a mobile air quality monitoring system could be effectively utilized in areas where event-based air pollution occurs, such as firework festivals or construction sites. In the future, by utilizing data from various regions, further improvements and enhancements can be made to the system, leading to a more efficient and accurate mobile air quality monitoring system.

Numerical investigation of two-component single-phase natural convection and thermal stratification phenomena in a rod bundle with axial heat flux profile

  • Grazevicius, Audrius;Seporaitis, Marijus;Valincius, Mindaugas;Kaliatka, Algirdas
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3166-3175
    • /
    • 2022
  • The most numerical investigations of the thermal-hydraulic phenomena following the loss of the residual heat removal capability during the mid-loop operation of the pressurized water reactor were performed according to simplifications and are not sufficiently accurate. To perform more accurate and more reliable predictions of thermal-hydraulic accidents in a nuclear power plant using computational fluid dynamics codes, a more detailed methodology is needed. Modelling results identified that thermal stratification and natural convection are observed. Temperatures of lower monitoring points remain low, while temperatures of upper monitoring points increase over time. The water in the heated region, in the upper unheated region and the pipe region was well mixed due to natural convection, meanwhile, there is no natural convection in the lower unheated region. Water temperature in the pipe region increased after a certain time delay due to circulation of flow induced by natural convection in the heated and upper unheated regions. The modelling results correspond to the experimental data. The developed computational fluid dynamics methodology could be applied for modelling of two-component single/two-phase natural convection and thermal stratification phenomena during the mid-loop operation of the pressurized water reactor or other nuclear and non-nuclear installations at similar conditions.

원전 복수계통 열교환기의 이음 원인 분석 (Abnormal Sound from Heat Exchanger of Condensate Water System at Nuclear Power Plant)

  • 이준신;이욱륜;김태룡
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.469-474
    • /
    • 2016
  • Abnormal sound was heard from a heat exchanger of condensate water system in a nuclear power plant, which was identified as impact sound of a loose part later. Nuclear power plants are normally equipped with loose part monitoring system for primary water system, but not for secondary water system. The abnormal sound was analyzed by using the impact signal-processing methodology based on the Hertz theory. The predicted results for impact location and size of the loose part showed good agreement with those of the actual loose part found during the overhaul period in the plant. So, this analysis methodology for the impact signal will be widely utilized for the primary and secondary side of the nuclear power plant.

의사결정나무를 이용한 비즈니스 프로세스의 실시간 위험 수준 측정 (Real-time Risk Measurement of Business Process Using Decision Tree)

  • 강복영;조남욱;김훈태;강석호
    • 산업경영시스템학회지
    • /
    • 제31권4호
    • /
    • pp.49-58
    • /
    • 2008
  • This paper proposes a methodology to measure the risk level in real-time for Business Activity Monitoring (BAM). A decision-tree methodology was employed to analyze the effect of process attributes on the result of the process execution. In the course of process execution, the level of risk is monitored in real-time, and an early warning can be issued depending on the change of the risk level. An algorithm for estimating the risk of ongoing processes in real-time was formulated. Comparison experiments were conducted to demonstrate the effectiveness of our method. The proposed method detects the risks of business processes more precisely and even earlier than existing approaches.

하천 수질에 대한 36시간 연속 모니터링 기법 연구 (36hrs Continuous Monitoring Methodology for Effluent and Receiving Water Quality)

  • 박정규;정홍배;문성환;류태권;류제영;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권4호
    • /
    • pp.153-159
    • /
    • 2001
  • The main point source of pollution of the Keumho river in Taegu, Korea, stems from waste from the areas of industrial complexes . Although it is widely accepted that pollutants in waste water negatively effects general water quality, it is difficult to evaluate the effluent effect because of varying conditions in ambient water and inconclusive knowledge of causative pollutants. To analyze the water in relation to the industrial effluent in the area, pH. temperature, conductivity, and Microtox toxicity of various river samples were measured. Water samples were collected every 2 hours for 36 hours from Keumho river and Dalseo stream. Data from continuous monitoring for 36 hours showed that effluent in Keumho river originated from Dalseo stream, which is near adjacent to industrial complexes. Change in toxicity and other factors tested during the 36 hours indicated that continuous monitoring was necessary for a satisfactory effluent toxicity test Furthermore, in addition to water quality monitoring, it was concluded that sediment toxicity also needed to evaluate effluent effects.

  • PDF

DSM Monitoring을 위한 수리모형 개발에 관한 연구 (A Study on Developing Mathematical Model for DSM Monitoring)

  • 김성일;임재윤;장승찬;김창섭;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.764-766
    • /
    • 1997
  • This paper presents a DSM Monitoring Methodology which is able to evaluate the impact of DSM programs under processing. For an effective assessment of DSM programs, it is foremost necessary to examine the market characteristics on the specific end-use appliance according to the customer's adoption of DSM programs. The Proposed Monitoring system contains a diffusion process of high efficient end-use considering major factors of DSM impact such as, price, price elasticity and lifetime of end-use apparatus or appliance. The case study shows the propriety and necessity of DSM monitoring in order to diagnose the current state and provide a baseline of DSM policy

  • PDF

수질자료의 불확실성이 수질관리에 미치는 영향 (Impacts of Uncertainty of Water Quality Data on Wate Quality Management)

  • 김건하
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.427-430
    • /
    • 2006
  • Uncertainty is one of the key issues of the water quality management. Uncertainty occurs in the course of all water quality management stages including monitoring, modeling, and regulation enforcement. To reduce uncertainties of water quality monitoring, manualized monitoring methodology should be developed and implemented. In addition, long-term monitoring is essential for acquiring reliable water quality data which enables best water quality management. For the water quality management in the watershed scale, fate of pollutant including its generation, transport and impact should be considered while regarding each stage of water quality management as an unit process. Uncertainties of each stage of water quality management should be treated properly to prevent error propagation transferred to the next stage of management for successful achievement of water quality conservation.

이산관측기에 근거한 감지시스템을 위한 정량적 성능지표 (A Quantitative Performance Index for Discrete-time Observer-based Monitoring Systems)

  • 허건수;김상진
    • 한국정밀공학회지
    • /
    • 제12권10호
    • /
    • pp.138-148
    • /
    • 1995
  • While Model-based Monitoring systems based on state observer theory have shown much promise in the laboratory, they have not been widely accepted by industry because, inpractice, these systems often have poor performance with respect to accuracy, band-width, reliability(false alarms), and robustness. In this paper, the linitations of the deterministic discrete-time state observer are investigated quantitatively from the machine monitoring viewpoint. The limitations in the transient and steady-state observer performance are quantified as estimation error bounds from which performance indices are selected. Each index represents the conditioning of the corresponding performance. By utilizing matrix norm theory, an unified main index is determined, that dominates all the indices. This index could from the basis for an observer design methodology that should improve the performance of model-based monitoring systems.

  • PDF

Real-time structural damage detection using wireless sensing and monitoring system

  • Lu, Kung-Chun;Loh, Chin-Hsiung;Yang, Yuan-Sen;Lynch, Jerome P.;Law, K.H.
    • Smart Structures and Systems
    • /
    • 제4권6호
    • /
    • pp.759-777
    • /
    • 2008
  • A wireless sensing system is designed for application to structural monitoring and damage detection applications. Embedded in the wireless monitoring module is a two-tier prediction model, the auto-regressive (AR) and the autoregressive model with exogenous inputs (ARX), used to obtain damage sensitive features of a structure. To validate the performance of the proposed wireless monitoring and damage detection system, two near full scale single-story RC-frames, with and without brick wall system, are instrumented with the wireless monitoring system for real time damage detection during shaking table tests. White noise and seismic ground motion records are applied to the base of the structure using a shaking table. Pattern classification methods are then adopted to classify the structure as damaged or undamaged using time series coefficients as entities of a damage-sensitive feature vector. The demonstration of the damage detection methodology is shown to be capable of identifying damage using a wireless structural monitoring system. The accuracy and sensitivity of the MEMS-based wireless sensors employed are also verified through comparison to data recorded using a traditional wired monitoring system.