• Title/Summary/Keyword: Monitoring device

Search Result 1,390, Processing Time 0.041 seconds

The implementation of the PC-based monitoring device for railway temperature environmental (PC기반의 철도 온도환경에 적합한 모니터링 장치 구현)

  • Bea, Goe-Sung;Son, Ki-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.819-825
    • /
    • 2014
  • The diurnal range of temperature in korea is increasing. We know that the environment has deteriorated through report about railway damage and economic loss caused by climate. In these conditions, Monitoring device for railway must operate to support the operations and maintenance. Therefore, In this paper, COM-based monitoring device implemented using Industrial-Extended electronic components and made, We tested compliance about temperature environment of actual railway. We verified through testing about cold and dry heat of monitoring device. Used components in this product will be able to utilize the development of the railway industry of electronics.

Smartphone-based O2 Deficiency Monitoring Device (스마트폰 기반 산소 결핍 모니터링 장치)

  • Loh, Byoung Gook
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.117-121
    • /
    • 2015
  • $O_2$-deficiency related accidents occur every year and the most effective way to prevent them is to measure $O_2$ concentration in air with a properly-calibrated $O_2$ monitoring device before entering low-$O_2$ areas. An electro-chemical sensor, Texas Instrument gas platform, and iPhone are used to construct a smartphone-based $O_2$ monitoring device. The smartphone based $O_2$ measuring approach offers advantages of small size, accessibility, internet-connectivity, and programmability in comparison to conventional $O_2$ measuring devices. Multiple gas sensors can be conveniently interfaced to single smartphone, allowing for creating a network of gas sensors distributed across workplaces and remote monitoring via existing mobile communication network. To check proper function of the $O_2$ monitoring device the sensor was exposed to shallow and deep human breaths. The readings decreased immediately after being exposed to exhalation and recovered during inhalation to a calibrated level of 20.9%. When readings decreased below a preset warning value of 19.5%, a low $O_2$ warning was successfully activated on the smartphone.

Valve monitoring system design and implementation using an infrared sensor and ZigBee (Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현)

  • Sim, Hyun;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • The valve device is installed in hazardous areas, such as a chemical plant explosion has been sealed with fire protection device to prevent the risk of explosion. In this paper, due to the explosion-proof devices using external power the device can not be used in infrared sensors and Zigbee sensor valve device by measuring the open degree of valve opening and closing of the danger zone to check whether. Valve opening and closing operation log screen time, we propose a low-power operation monitoring system administrators to manage and control the plant. Develop power control relay board apply an improved algorithm to apply the asynchronous LPL power management. The plant monitoring system and explosion-proof valve opening and closing the valve system with the intelligent device designed and implemented and tested it.

Development of a Bath Assistive System with Water Temperature Monitoring to Prevent Heart Attack (수온 모니터링 기능을 탑재한 심장마비 방지용 목욕 보조 시스템)

  • Kang, So Myoung;Wei, Qun
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.242-249
    • /
    • 2019
  • Old people and patients with cardiovascular disease could die of a heart attack in the bath with heated water for a long time. Various researches have been studied to prevent these accidents from happening such as measuring the ECG signal when taking bath. However, these devices are hard to use and the higher price is not easily accepted by the public. In this paper, a low-cost and use-friendly, real time high precision water temperature monitoring device to prevent heart attack in the bath was developed. The device with waterproof design that lets the device can float on the surface of the water, and an accurate way to make water temperature measurement method was proposed by this paper that is immerging the sensor into water with 4cm depth to measure the temperature of underwater. The manufactured device was conducted to two experiments; one was to verify the basic functions of the device, and another one was for compare the proposed device with commercial products for monitoring the water temperature in the bathtub. As the experimental results shown, the proposed device has stable performance for the water temperature measurement and communicating with laptop in wireless.

Development of usability evaluation index of convergence technology remote fluid monitoring device for non-face-to-face patient nursing system application and analysis of results (비대면 환자 간호시스템 적용을 위한 융합기술의 원격 수액모니터링 장치 사용성평가 지표 개발 및 결과 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.137-145
    • /
    • 2022
  • The usability evaluation of the remote fluid monitoring device, which was introduced to reduce the work of nurses and increase the efficiency, was performed due to the expansion of the non-face-to-face medical system. Remote fluid monitoring is a fusion of various technologies such as fluid measurement and analysis, error correction technology, and transmission technology. The range of use by users, the information they want to obtain, and the control device, etc. are wide, and the factors that evaluate the product are also diverse. Therefore, it is difficult to improve the product through evaluation. In this study, a quantitative index was developed to help improve the product for commercialization by conducting 20 usability evaluations in three areas of product stability, operability, and satisfaction with the remote sap monitoring system device. It was performed through infrared and load cell-type sap monitoring devices. In terms of stability, there was a difference in installation work such as fixing the pole of the device, and high satisfaction was shown for operability and accuracy. In terms of product satisfaction, the satisfaction of load cell devices was generally high.

Web Based Monitoring Systems for Multi-Axis Force/Torque Sensors Using Embedded Systems

  • Nam, Hyun-Do;Lim, Hong-Sik;Kang, Chul-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1675-1678
    • /
    • 2004
  • In this paper, web based monitoring systems are implemented for multi-axis force control systems of an intelligence robot. A brief review about the principle of multi-axis force sensors and a method that can reduce the effect of noise signal to sensor performance is presented. A web based monitoring system is implemented by porting Linux at embedded systems which include Xscale processors. A device driver is developed to receive data from multi-axis force sensors in Linux operation systems. To control this device driver, a socket program for web browser is also developed. The experiments are performed to investigate the effectiveness of proposed methods. The experimental results show that the values of force sensors can be monitored by remote PCs.

  • PDF

Wearable Human Health-monitoring Band using Inkjet-printed Flexible Temperature Sensor

  • Han, Dong Cheul;Shin, Han Jae;Yeom, Se Hyeok;Lee, Wanghoon
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.301-305
    • /
    • 2017
  • This paper presents a wearable human health-monitoring band. The band consists of a body temperature detector (BTD) and a hear rate detector (HRD). The BTD and HRD are realized using an inkjet-printed flexible temperature sensor and a commercial heart rate sensor module, respectively. The sensitivity of the fabricated BTD was found to be $-31/^{\circ}C$ with a linearity of 99.82%. The HRD using the commercial heart rate sensor module has a good performance with a standard deviation of 0.85 between the data of a commercial smart watch and the fabricated HRD.

Study on Process Monitoring of Elliptical Vibration Cutting by Utilizing Internal Data in Ultrasonic Elliptical Vibration Device

  • Jung, Hongjin;Hayasaka, Takehiro;Shamoto, Eiji
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • v.5 no.5
    • /
    • pp.571-581
    • /
    • 2018
  • In the present study, monitoring of elliptical vibration cutting process by utilizing internal data in the ultrasonic elliptical vibration device without external sensors such as a dynamometer and displacement sensor is investigated. The internal data utilized here is the change of excitation frequency, i.e. resonant frequency of the device, voltages applied to the piezoelectric actuators composing the device, and electric currents flowing through the actuators. These internal data change automatically in the elliptical vibration control system in order to keep a constant elliptical vibration against the change of the cutting process. Correlativity between the process and the internal data is described by using a vibration model of ultrasonic elliptical vibration cutting and verified by several experiments, i.e. planing and mirror surface finishing of hardened die steel carried out with single crystalline diamond tools. As a result, it is proved that it is possible to estimate the elements of elliptical vibration cutting process, e.g. tool wear and machining load, which are important for stable cutting in such precision machining.

Evaluation of CDMA Network Based Wireless 3 Channel ECG Monitoring System (CDMA망 기반 3채널 심전도 모니터링 시스템의 평가)

  • Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.295-301
    • /
    • 2008
  • A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.

A Study on the A·R type Monitoring Technique using QR-code and Environment Monitoring Sensor Based on Smart Device (QR코드와 환경감시센서를 활용한 스마트 디바이스기반 증강현실형 환경모니터링 기술 연구)

  • Kim, Chan;Shin, Jaekwon;Cha, Jaesang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.261-265
    • /
    • 2012
  • The applications of augmented reality technology is increasing in the several field by IT convergence and we find augmented reality application easily in the smart device application area. And then, to attempt to use augmented reality technology in advantage, exhibitions and performances was activated. However, it less than other fields of augmented reality technology expertise yet. Among them services to Use in fusion with monitoring are lacking. In this paper, we proposed the augmented reality monitoring technology based on smart device. It is able to incorporate QR-code which is already building for the purpose of advertising promotional materials with augmented reality technology in many areas. Therefore, it is able to utilize unattended building or automation equipment facilities using QR-code and environmental monitoring sensor in the industry.