• Title/Summary/Keyword: Monitoring channel

검색결과 459건 처리시간 0.025초

압전 잉크젯 헤드 모니터링 시스템 (Piezo-driven inkjet printhead monitoring system)

  • 이병렬;김상일
    • 센서학회지
    • /
    • 제19권2호
    • /
    • pp.124-129
    • /
    • 2010
  • For the industrial printing applications, the stability of the piezo-driven inkjet printhead is a major requirement. In this paper, we focused on the failure modes of the inkjet printhead and realized a method to detect and repair them at high speed. The printhead monitoring is performed by detecting the residual vibration of the actuating plate using the self- sensing capability of the piezoelectric material. To measure the channel acoustics and to identify the malfunctioning nozzle, we devised the bridge sensing circuitry and failure detection algorithm. The residual vibration signals can be affected by the boundary conditions of the channel acoustics, so it is possible to identify the failure causes by analyzing the monitoring signals. Therefore it is also possible to apply a proper restoring process to the defective printhead. The experimental results show that this method is effective in improving the reliability of the industrial printing.

원격 감시와 제어를 위한 IDLC 채널뱅크의 설계 및 구현 (Design and Implementation of IDLC Channel Bank for Remote Monitoring and Control)

  • 하수호;한성화
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.409-412
    • /
    • 2000
  • In this paper we have implemented CH-MUX system which provides customers with various services, i.e. POTS, ISDN, digital leased line and so on, and supports not only UDLC but IDLC network configuration based on existing optical transmission facilities. Also the RCS equipment has been designed and implemented for remote monitoring and control of CH-MUXs. And then this paper has described IPC procedure and proposed other implemental methods of IPC channel. Service providers will be able to design and construct cost-effective access network with RCS and CH-MUX systems.

  • PDF

핵연료 건전성 점검을 위한 감마선 스펙트럼의 자동 분석 (Automatic Analysis of Gamma Ray Spectra for Surveillance of the Nuclear Fuel Integrity)

  • Cho, Joo-Hyun;Yu, Sung-Sik;Kim, Seong-Rae;Hah, Yung-Joon
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.555-561
    • /
    • 1994
  • 핵연료 건전성 점검을 위하여 다중채널분석기로 얻은 감마선 스펙트럼을 자동으로 빨리 분석하는 프로그램을 개발하였다. 핵연료의 건전성은 실시간 감시와 주기적인 시료 분석을 통한 원자로냉각재내의 방사선준위로 확인된다. 영광 3·4 호기의 경우, 실시간 감시 계통인 프로세스 방사선 감시 계통(PRMS)이 핵연료의 건전성을 확인한다. 현재, PRMS의 스펙트로미터 채널의 신호처리기는 단일채널 분석기이어서 오직 하나의 방사성핵종만을 파악할 수 있다. 따라서 PRMS를 개선하기 위해서는 단일채널분석기를 다중채널분석기로 대치하여야 한다. 이 프로그램은 실시간 모드와 수동모드로 실행되며, 모든 과정을 자동으로 수행한다. 미 국가표준국의 혼합 표준 선원에 대한 시험 결과는 상용 다중채널분석기인 Canberra System 100의 결과와 잘 일치하였다. 결론적으로 개발된 프로그램은 원자력발전소의 감마선 감시에 사용할 수 있을 것으로 보인다.

  • PDF

단일채널 복부 심전도를 통한 태아 심전도 분리 (A Study on the Separation of Fetal ECG from a Single Channel Abdominal ECG)

  • 박광리;이경중;이전
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권3호
    • /
    • pp.198-205
    • /
    • 2005
  • In this paper, we proposed a new algorithm for the separation of fetal ECG from single channel abdominal ECG. The algorithm consists of a stage of demixing vector calculation for initial signal and a stage of fetal beat detection for the rest of signal. The demixing vector was obtained by applying independent component analysis technique to projected signals into time-frequency domain. For the test of this algorithm, simulation signals, De Lathauwer's data and some measured data, which was acquired from 8 healthy volunteers whose pregnant periods ranged from 22 weeks to 35 weeks and whose ages from 27 to 37, were used. For each data, the accuracy of fetal beat detection was $100\%$ and with the location of fetal beats, fetal heart rate variability and morphology could be offered. In conclusion, this proposed algorithm showed the possibility of fetal beat separation with a single channel abdominal ECG and it might be adopted to a fetal health monitoring system, by which a single channel abdominal ECG is acquired.

Reconfigurable Optical Add-Drop Multiplexer Using a Polymer Integrated Photonic Lightwave Circuit

  • Shin, Jang-Uk;Han, Young-Tak;Han, Sang-Pil;Park, Sang-Ho;Baek, Yong-Soon;Noh, Young-Ouk;Park, Kang-Hee
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.770-777
    • /
    • 2009
  • We have developed a fully functional reconfigurable optical add-drop multiplexer (ROADM) switch module using a polymer integrated photonic lightwave circuit technology. The polymer variable optical attenuator (VOA) array and digital optical switch array are integrated into one polymer PLC chip and packaged to form a 10-channel VOA integrated optical switch module. Four of these optical switch modules are used in the ROADM switch module to execute 40-channel switching and power equalization. As a wavelength division multiplexer (WDM) filter device, two C-band 40-channel athermal arrayed waveguide grating WDMs are used in the ROADM module. Optical power monitoring of each channel is carried out using a 5% tap PD. A controller and firmware having the functions of a 40-channel switch and VOA control, optical power monitoring, as well as TEC temperature control, and data communication interfaces are also developed in this study.

사물인터넷 기반의 다중채널 생체신호 측정 (Acquisition of Multi-channel Biomedical Signals Based on Internet of Things)

  • 김정환;정겨운;이준우;김경섭
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1252-1256
    • /
    • 2016
  • Internet of Things(IoT)-devices are now expanding inter-connecting networking technologies to invent healthcare monitoring system especially for assessing physiological conditions of the chronically-ill patients those with cardiovascular diseases. Hence, IoT system is expected to be utilized for home healthcare by dedicating the original usage of IoT devices to collect the biomedical data such as electrocardiogram(ECG) and photoplethysmography(PPG) signal. The aim of this work is to implement health monitoring system by integrating IoT devices with Raspberry-pi components to measure and analyze ECG and the multi-channel PPG signals. The acquired data and fiducial features from our system can be transmitted to mobile devices via wireless networking technology to support the concept of tele-monitoring services based on IoT devices.

해양 유독생물의 독성 검사와 보건환경 모니터링을 위한 조건센서의 활용 (Practical Use of Tissue Biosensor for Safety Test of Marine Organism and Monitoring of Public Health and Environment)

  • 천병수;유종수;유진형;도변탈생
    • KSBB Journal
    • /
    • 제14권1호
    • /
    • pp.1-8
    • /
    • 1999
  • It confirmed the facilitated diffusion of $Na^+$ of frog bladder membrane which is a tissue membrane. The mechanism was explained in $Na^+$ channel model and its referred to the $Na^+$ channel obstruction ingredient which was contained in the reference to the $Na^+$ channel obstruction ingredient and son on, e.g., seaweed, shellfish, pufferfish, phytoplankton and chinese drug. Also, it introduces the result which studied from the barrier point of the application of the tissue biosensor to the trade friction on Korea or Japan pufferfish and the marine environment in the one with high dependance. It was possible for the poison quantity of small amount pufferfish toxin (TTX), paralytic shellfish poisoning (PSP) to be measured and also to measure poison quantity in the cultivation poisonous toxin phytoplankton individual. In future, as for this tissue biosensor, it expects that it is possible to contribute widely until environment watch and also monitoring to the scene.

  • PDF

디지털 신호처리기를 사용한 태아심전도 신호 추출 시스템 (A Fetal ECG Signal Monitoring System Using Digital Signal Processor)

  • 박영철;조병모;김남현;김원기;박상휘;연대희
    • 대한전자공학회논문지
    • /
    • 제26권9호
    • /
    • pp.1444-1452
    • /
    • 1989
  • This paper describes the implementation of a real time fetal ECG monitoring system in which an adaptive multi-channel noise canceller is realized using the Texas Instruments TMS32020 progrmmmable ditital signal processor. An ECG signal from the electrode placed on the mother's abdomen and three ECGs from those on the chest are applied as the desired signal and the referened inputs, respectively, of the multi-channel filter. The coefficients of the filter are updated using the LMS algorithm such that the output of the multi-channel filter copies the maternal ECG embedded in the abdominal ECG. The enhanced fetal ECG is obtained by subtracting the filter output from the abdominal ECG, and the difference signal is recorded. Both off-line and on-line experimental results are presented to verify the effectiveness of the parameters for the digital signal processing algorithms and the prototype system.

  • PDF

지하철 터널 유지관리 계측센서의 총 손망실율 산정 연구 (A study on estimation of the total loss and damage ratio of maintenance monitoring sensor of subway tunnel)

  • 우종태
    • 한국터널지하공간학회 논문집
    • /
    • 제15권1호
    • /
    • pp.25-31
    • /
    • 2013
  • 본 논문은 지하철 터널 유지관리 계측센서의 총 손망실율을 산정하기 위해 국내와 국외의 지하철 터널구조물에 설치되어 운영 중에 있는 유지관리 계측센서의 손망실 현황을 조사하고 분석을 실시하였다. 지하철 터널 유지관리 계측센서 설치 후 5~6년 경과된 시점을 기준하여 총 손망실율은 서울지하철5,6,7호선에서 14.2%, 서울지하철9호선1단계구간에서 14.8%, 영국의 Channel tunnel에서 13.9%로 모두 15%에 근접하게 나타났다. 따라서 지하철 터널 유지관리 계측센서의 총 손망실율은 잠정적으로 15%로 설정하여 설계에 반영하는 것이 타당한 것으로 판단되며, 향후 장기간의 경과년수에 따른 계측항목별 손망실율 연구가 필요할 것으로 판단된다.

Wireless Impedance-Based SUM for Bolted Connections via Multiple PZT-Interfaces

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제31권3호
    • /
    • pp.246-259
    • /
    • 2011
  • This study presents a structural health monitoring (SHM) method for bolted connections by using multi-channel wireless impedance sensor nodes and multiple PZT-interfaces. To achieve the objective, the following approaches are implemented. Firstly, a PZT-interface is designed to monitor bolt loosening in bolted connection based on variation of electro-mechanical(EM) impedance signatures. Secondly, a wireless impedance sensor node is designed for autonomous, cost-efficient and multi-channel monitoring. For the sensor platform, Imote2 is selected on the basis of its high operating speed, low power requirement and large storage memory. Finally, the performance of the wireless sensor node and the PZT-interfaces is experimentally evaluated for a bolt-connection model Damage monitoring method using root mean square deviation(RMSD) index of EM impedance signatures is utilized to estimate the strength of the bolted joint.