• 제목/요약/키워드: Monitoring Right

검색결과 277건 처리시간 0.03초

우발적인 척추동맥으로의 중심정맥 카테터의 삽관 (Accidental Vertebral Artery Cannulation as a Complication of the Central Venous Catherization)

  • 정주호
    • Journal of Trauma and Injury
    • /
    • 제27권2호
    • /
    • pp.33-37
    • /
    • 2014
  • Central venous catheterization through a subclavian approach is indicated for some special purposes but it may cause many complications such as infection, bleeding, pneumothorax, thrombosis, air embolization, arrhythmia, myocardial perforation, and nerve injury. A case involving a mistaken central venous catheterization into the right vertebral artery through the subclavian artery is presented. A 33-year-old man who had deteriorated mentality after head injury underwent an emergency craniotomy for acute epidural hematomas on the right frontal and temporal convexities. His mentality improved rapidly, but he complained of continuous severe pain in the right posterior neck even though he had no previous symptom or past medical history of such pain. Three-dimensional cervical spine computed tomography (3D-CT) was performed first to rule out unconfirmed cervical injuries and it revealed a linear radiopaque material intrathoracically from the level of the 1st rib up to the level of C6 in the right vertebral foramen. An additional neck CT was performed, and the subclavian catheter was indwelling in the right vertebral artery through right subclavian artery. For the purpose of proper fluid infusion and central venous pressure monitoring, the subclavian vein catheterization had been performed in the operation room after general anesthesia induction before the craniotomy. Sufficient anatomical consideration and prudence is essential because inadvertent arterial cannulation at a non-compressible site is a highly risky iatrogenic complication of central venous line placement.

A Framework for Computer Vision-aided Construction Safety Monitoring Using Collaborative 4D BIM

  • Tran, Si Van-Tien;Bao, Quy Lan;Nguyen, Truong Linh;Park, Chansik
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1202-1208
    • /
    • 2022
  • Techniques based on computer vision are becoming increasingly important in construction safety monitoring. Using AI algorithms can automatically identify conceivable hazards and give feedback to stakeholders. However, the construction site remains various potential hazard situations during the project. Due to the site complexity, many visual devices simultaneously participate in the monitoring process. Therefore, it challenges developing and operating corresponding AI detection algorithms. Safety information resulting from computer vision needs to organize before delivering it to safety managers. This study proposes a framework for computer vision-aided construction safety monitoring using collaborative 4D BIM information to address this issue, called CSM4D. The suggested framework consists of two-module: (1) collaborative BIM information extraction module (CBIE) extracts the spatial-temporal information and potential hazard scenario of a specific activity; through that, Computer Vision-aid Safety Monitoring Module (CVSM) can apply accurate algorithms at the right workplace during the project. The proposed framework is expected to aid safety monitoring using computer vision and 4D BIM.

  • PDF

진돗개에서 심장초음파 측정치와 평가와 임상적 응용 (Echocardiograpyhic Assessment and Clinical Application of Cardiac Disease in Korea Jin-do Dog III. Detection of Heartworm)

  • 박인철;강병규;손창호
    • 한국임상수의학회지
    • /
    • 제17권1호
    • /
    • pp.194-204
    • /
    • 2000
  • Echocardiography was performed to obtain the optimal planes for diagnosis of canine heartworm disease in 11 dogs. Imaging planes were taken the left ventricular outflow tract long-axis view, 4-chamber long-axis view, chordae tendineae level short-axis view and modified pulmonary arteries level short-axis view in the right parasternal window, and aptical 4-chamber long-axis view in hte left parasternal window. After echocaridography, the pulmonary artery valve pat was ligated with double 1-0 silk under the general anesthesia to prevent heartworm moving from pulmonary artery to right ventricle. The dogs were euthanized and examained for heartworms in heart and great vessels. Many adult heartworms were identified ultrasonographically within main pulmonary artery, bifurcation of pulmonary artery and right pulmonary artery, but not identified within right ventricle and atrium. At necropsy, adult heartworms were mainly found in pulmonary artery in 11 days, and also found in right ventricular outflow tract and right ventricle in 2 of 11 dogs. The modified pulmonary arteries level short-axis view was the best imaging plane for identifiying heartworms because the main pulmonary artery, branches of pulmonary artery and right pulmonary artery could be showed. The aortic root internal dimension (AOID) and right pulmonary atery internal dimension (RPAID) were measured from the modified pulmonary ateries level short-axis view and left ventricular outflow tract long-axis view. The RPAID and RPAID/AOID was higher in heartworm infected dogs than normal Korea Jin-do dogs in modified pulmonary arteries level short-axis view, and the AOID, RPAID and RPIAID/AOID was higher than in left ventricular outflow tract long-axis view, respectively. These results indicate that the pulmonary arteries were the major habitat of adult heartworm in canine heartworm disease and the modified pulmonary arteries level short-axis view was the best imaging planes for identifying heartworms because the main pulmonary arteries could be showed. Therefore the modified pulmonary arteries level short-axis view can be used for diagnosing heartworm disease and for monitoring dilation of pulmonary artery.

  • PDF

철도승강장 모니터링을 위한 스테레오카메라 개발연구 (Development of Stereo Camera for Railway Platform Monitoring)

  • 원종운;오세찬;김길동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.293-293
    • /
    • 2010
  • In this paper, we propose a stereo vision based monitoring concept for passenger's safety on railroad platform. In general, basic concept of stereo image processing technique uses the correlations between left and right images, and extracts additional distance information. It provides easy removal of ambient illumination changes, which has been difficult to achieve with conventional 2D based image processing technique. In the paper, we present developed stereo camera and stereo vision based detection algorithm in order to monitor possible accidents at platform area, and verified the detection performance of proposed system with experimental results.

  • PDF

Usefulness of Motor-Evoked Potentials Monitoring for Neurosurgical Treatment of an Unusual Distal Anterior Choroidal Artery Aneurysm

  • Champeaux, Charles;Jecko, Vincent;Eimer, Sandrine;Penchet, Guillaume
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.414-419
    • /
    • 2016
  • A 35 years old woman presented with an acute meningeal syndrome following an intra ventricular haemorrhage without subarachnoid haemorrhage. The angiography demonstrated a 6 mm partially thrombosed saccular aneurysm at the plexal point of the right anterior choroidal artery (AChoA). It was surgically approached inside the ventricle through a trans-temporal corticotomy. The aneurysm was excised after distal exclusion of the feeding artery under motor-evoked potentials monitoring. Of the 19 cases of distal AChoA aneurysm neurosurgical treatment, this is the only one performed under electrophysiology monitoring, a simple and safe method to detect and prevent motor tract ischemia. We discuss this rare case, along with a comprehensible review of the literature of the previous surgical cases of distal AChoA aneurysms.

RBM 굴착에 따른 수직구의 3차원적 거동 연구 (A study on the 3-dimensional behavior of shaft by the RBM reaming)

  • 조만섭;이석원;마상준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.717-724
    • /
    • 2002
  • To investigate the behavior of air-shaft and existing tunnel by excavating the small-diameter shaft into the existing tunnel, prototype air-shaft was constructed and analyzed in this study. Geotechnical characterization was conducted by boring and rock cores obtained were tested in the laboratory. Field monitoring including radial and tangential stresses and displacements was conducted with the 3-dimensional numerical analysis of prototype air-shaft. Results of field monitoring were compared with the numerical results. The results showed that maximum displacement of 2.11mm and maximum tangential stress of 54.0 kg/$\textrm{cm}^2$ were obtained during shaft excavation near the right shoulder of the existing tunnel. The comparison of these field measurements with 3-dimensional numerical analysis showed that much more higher stress was measured during excavation compared to the numerical results even though the trends of stress and displacement were similar.

  • PDF

라이센스 에이젼트를 이용한 멀티미디어 데이터관리 및 감시 시스템 설계 (The Design of a Multimedia Data Management and Monitoring System for using License Agent)

  • 조현섭;유인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1662-1664
    • /
    • 2007
  • As the logistic environment of digital contents is rapidly changing, the protection of the digital rights for digital content has been recognized as one of critical issues. Digital Right Management(DRM) has taken much interest Internet Service Provider(ISP), authors and publishers of digital content as an interested approach to create a trusted environment for access and use of digital resources. This paper propose an interested digital rights protection scheme using license agent to address problems facing contemporary DRM approached : static digital rights management, and limited application to on-line environment. We introduce a dynamic mission control technology to realize dynamic digital rights management. And we incorporate license agent to on- and off-line monitoring and tracking. The proposed system prevent illegal access and use by using PKI security method, real time action monitoring for user, data security for itself.

  • PDF

디지털 저작권 보호를 위한 라이센스 에이전트의 설계 (The Design of License Agent Rights Protection)

  • 이광형;이근왕;김희숙
    • 한국사이버테러정보전학회:학술대회논문집
    • /
    • 한국사이버테러정보전학회 2004년도 제1회 춘계학술발표대회
    • /
    • pp.275-282
    • /
    • 2004
  • 디지털 저작물의 전송환경이 빠른 속도로 바뀜에 따라서 디지털 저작물의 저작권 보호가 중요한 이슈로 부각되고 있다. DRM(Digital Right Management)은 디지털 저작자나 출판업자, 그리고 인터넷 서비스 제공자들에게 디지털 저작물을 접근하고 사용하는데 있어서 신뢰할수 있는 환경을 만들수 있는 관심있는 분야이다. 본 논문에서는 라이선스 에이전트를 이용하여 기존의 DRM 기법이 가지고 있는 정적인 DRM이나 온라인환경에 제한된 어플리케이션의 단점을 개선한 디지털 저작물의 보호기법에 대하여 제안한다. 제안된 논문은 동적인 DRM기법으로 동적인 요구 제어 기술을 바탕으로 라이선스 에이전트를 이용하여 온라인과 오프라인 환경에서 동시에 모니터링과 추적을 수행한다. 제안된 시스템은 PKI 보안 환경에서 사용자의 행동이나 데이터 보안을 실시간으로 감시하여 불법적인 접근과 사용을 막는다.

  • PDF

흉강경하 교감신경절 소작술중 발생한 심부전 -증례 보고- (Heart Failure Occurred during Endoscopic Transthoracic Sympathetic Cauterization -A case report-)

  • 이윤우;윤덕미;안은경;석미자
    • The Korean Journal of Pain
    • /
    • 제9권1호
    • /
    • pp.235-238
    • /
    • 1996
  • Hyperhidrosis is the distressing condition of abnormal sweating which affects the palm, sole and axillary region. Transthoracic endoscopic sympathectomy is recommended as the treatment of choice for hyperhidrosis, especially when the upper limbs are affected. We experienced a case of accidental cauterization of right azygos vein in a healthy 23 year old male during endoscopic transthoracic sympathectomy. We changed the single lumen endotracheal tube to a double lumen tube which made it easier to perform the explo-thoracotomy and bleeder ligation under one lung ventilation. Crystalloid and colloid solutions, and packed RBC were loaded during explo-thoracotomy. Monitoring showed the signs indicating pulmonary edema. Pulmonary arterial catheterization revealed global heart failure. The patient was transfered to ICU for intensive management for heart failure. On the 4th postoperative day, pulmonary edema and heart failure were cured; and the patient was extubated. But in the evening of the same day ST-segment elevation and Q-wave were noted on ECG monitoring. On the 13th postoperative day coronary angiography was performed. This revealed left apex focal hypokinesia, patent coronary artery and accidental right coronary spasm, treated by vasodilator. On the 14 day, after surgery, he was discharged to return to work.

  • PDF

진동 감시용 위치 결정 센서의 위상오차에 대한 실험적 고찰과 비교평가 (The Experimental Study and Comparison on Usage of Vibration Monitoring Sensors for Positioning of Balancing on Rotating Machinery)

  • 오승태;유무상;봉석근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.314-320
    • /
    • 2014
  • Field balancing is required in any kind of phase information for the determination location balancing mass toward a rotor unbalance mass. Phase or phase angle is a measurement of the relationship of how one vibration signal which relates to another vibration signal and is commonly used to calculate the placement of balance weight. In this paper, A right guideline shows the photo optical speed sensor as the external keyphasor is a very useful when diagnosing machinery vibration problems on considering a phase lag comparing to the laser optical speed sensor. Some experimental results generate the interesting phase errors when appling to a wrong conditions. So, Usage of photo optical speed sensor which is used primarily to measure the shaft rotating speed serves as a reference for measuring vibration phase information has effect on the placement of phase angle how it was misunderstood. This paper will help a right method to search for the position of balancing weight and serves as baseline for further measurements using low cost and much easier user convenience. It is concluded that the propose baseline is likely to be applicable to apply to the practical field balancing weight.

  • PDF