• Title/Summary/Keyword: Monitoring & control system

Search Result 2,975, Processing Time 0.032 seconds

A study on the Internet control and monitoring system using a microprocessor embedded controller (마이크로프로세서를 이용한 인터넷 원격감시제어 시스템에 관한 연구)

  • 서인호;문복산;김경엽;김영일;천행춘;유영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.152-156
    • /
    • 2000
  • Many industrial equipments use RS-232C interface. But Ethernet using CSMA/CD was widly spread recently. This interface is not compatible with RS-232C and requires PC based system. So In this Paper, We decribe a Internet control and monitoring system that control and watch plants without PC. We developed IP controller consisted of microprocessor and NIC and monitoring system using VC++ and SQL database. The protocol used this system is UDP/IP because it is applicable for real time system.

  • PDF

Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX (AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현)

  • Yang, Oh;Lee, Heon-Guk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

Web-based Building Automation System using Embedded Linux (임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템)

  • 신은철;이수영;최병욱
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

Web based control modules Using LonWorks/Ethernet Server for Control a large Scale Renewable Energy System in Building (빌딩용 신.재생에너지시스템 제어를 위한 LonWorks기반 원격 제어모듈 개발)

  • Hong, Wonl-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1706-1711
    • /
    • 2008
  • This paper proposes a new Web based-control concept & design method and implementation of LonWorks network system for a large scale renewable energy energy control and monitoring system in building. The Experimental LonWorks network system using LonWorks/Ethernet(Web) server is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting LonTalks protocol to Modbus protocol and software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, Especially, The seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide a available technical data for remote distributed control system of industrial and buildings field.

  • PDF

Development of Remote Monitoring System of Temperature Controller for Cold-Storage (저온냉장장치용 온도제어기의 원격 모니터링 시스템 개발)

  • Lim, Dae-Young;Ryoo, Young-Jae;Chang, Young-Hak;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2486-2488
    • /
    • 2003
  • This paper describes a remote monitoring system of temperature controller for cold-storage, of farm produce. In the cold-storage, it is important that farm produces are fresh. Unfortunately, when an operator goes out from the cold-storage temperature change could be occurred due to the various reasons, for an example, a valve of cooler is broken. The temperature change results in a serious problem of the quality of farm produce. To prevent the problem, the operator has to look to the current state of the temperature of the cold-storage, even he is in long away. Thus, the monitoring system to show the temperature should be required to the operator who can move away. Therefore, this paper propose of the remote monitoring system of the temperature. The proposed system is expected to help the operator's facilities, and the management of farm produce.

  • PDF

On the Configuration and Improvement of Security Control Systems (보안관제시스템 구성 및 개선방안 연구)

  • Yoo, Seung Jae
    • Convergence Security Journal
    • /
    • v.17 no.2
    • /
    • pp.69-80
    • /
    • 2017
  • Due to the advanced IT environment, the role of Security Monitoring & Control becomes more important as the cyber-crime is becoming intelligent, diversified, and advanced. In contrast to the way it relied solely on security devices such as Firewall and IDS in the past, Security Monitoring & Control tasks responding to cyber attacks through real-time monitoring have become wide spread and their role is also important. In response to current cyber threats, since security equipment alone can not be guaranteed a stable defense, the task of Security Monitoring & Control became essential to operate and monitor security equipment and to respond in real time. In this study, we will discuss how to configure network security system effectively and how to improve the real-time Security Monitor & Control.

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

An Effective Multivariate Control Framework for Monitoring Cloud Systems Performance

  • Hababeh, Ismail;Thabain, Anton;Alouneh, Sahel
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.1
    • /
    • pp.86-109
    • /
    • 2019
  • Cloud computing systems' performance is still a central focus of research for determining optimal resource utilization. Running several existing benchmarks simultaneously serves to acquire performance information from specific cloud system resources. However, the complexity of monitoring the existing performance of computing systems is a challenge requiring an efficient and interactive user directing performance-monitoring system. In this paper, we propose an effective multivariate control framework for monitoring cloud systems performance. The proposed framework utilizes the hardware cloud systems performance metrics, collects and displays the performance measurements in terms of meaningful graphics, stores the graphical information in a database, and provides the data on-demand without requiring a third party software. We present performance metrics in terms of CPU usage, RAM availability, number of cloud active machines, and number of running processes on the selected machines that can be monitored at a high control level by either using a cloud service customer or a cloud service provider. The experimental results show that the proposed framework is reliable, scalable, precise, and thus outperforming its counterparts in the field of monitoring cloud performance.

Problems of Assignable Causes in Process Monitoring and Adjustment (공정 모니터링과 조절에 있어 이상원인의 문제)

  • 이성철;전상표
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.4
    • /
    • pp.19-32
    • /
    • 2000
  • Assignable causes producing temporary deviation from the underlying system can influence on process adjustment and process monitoring in dynamic feedback control system. In this paper, the impact of assignable causes on EWMA forecasts and process adjustment which is based on the EWMA forecasts are derived for optimum control methods.

  • PDF

Development of Monitoring System for Wind Turbine (풍력발전기 원격모니터링 시스템 구축 및 개발)

  • Cha, Jang-Hyun;Lee, Jeong-Wan;Yoo, Neung-Soo;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.63-68
    • /
    • 2006
  • In this paper, remote monitoring system for wind turbine is developed. The developed system consists of data acquisition for wind sensor, and monitoring for site environment. In order to accomplish effective monitoring, the system uses Datasocket, SMB, FTP, Web Server, and G Web Server. Two computer system - one is data acquisition computer using Windows-XP and the other is monitoring computer using UNIX - constraint the distribute system with individual tasks. By using this system, one can perform various monitoring and control tasks in Wind-Turbine application, efficiently.

  • PDF