• Title/Summary/Keyword: Monitoring %26 control system

Search Result 65, Processing Time 0.032 seconds

The Effect of Behavior Modification on Enhancing Patient Adherence to Tuberculosis Treatment Regimens (Video프로그램을 통한 환자교육이 결핵환자 치료이행행위에 미치는 영향)

  • 정은리
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.3
    • /
    • pp.697-708
    • /
    • 1996
  • Most efforts to improve tuberculosis treatment adherence target the patient and his or her behavior. This study examined the effects of behavioral modification training for these patients. Based on Bandura's behavioral principles of modeling, intervention strategies using a video program were devised to elicit specific patient target behaviors considered to improve patients' adherence to tuberculosis treatment regimens. A random assignment, two-group(experimental group and control group) research design including 81 subjects was used. The main outcomes measured were pill taking measured with the Medication Event Monitoring System(MEMS) Medication Cap, patients' self-efficacy, and their knowledge of tuberculosis. The findings are as follows : 1) There was a significant difference between the experimental group and the control group in patients' feelings of self-efficacy. That is, the patients who received the behavior modification program showed greater feeling of self-efficacy to initiate and change their behavior for the tuberculosis treatment regimen than the patients who did not receive the program(t=3.51, p=0.01). 2) There was a significant difference between the experimental group and the control group in patients' knowledge of tuberculosis. That is, the patients who received the behavior modification program showed higher level of knowledge of tuberculosis than the patients who did not receive the program(t=2.15, p=0.03) 3) There was a significant difference between the experimental group and the control group in patients' adherence to tuberculosis treatment regimens. That is, the patients who received the behavior modification program showed greater adherence to the treatment regimens than the patients who did not receive the program(t=5.11, p=0.00). The study findings provided useful insights into nursing practice, particularly in planning intervention strategies aimed at enhancing patients' adherence in tuberculosis that may also be relevant to other chronic diseases with patient adherence problems.

  • PDF

Research on Vehicle Diagnostic and Monitoring technology Using WiBro Portable Device (와이브로 휴대기기를 사용한 차량진단 및 모니터링 기술에 관한 연구)

  • Ryoo, Hee-Soo;Won, Yong-Gwan;Park, Kwon-Chul;Ahn, Yong-Beom
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.10
    • /
    • pp.17-26
    • /
    • 2010
  • This is concerned with the technology to monitor the vehicle operation, failure and disorder by using WiBro portable device. More precisely, the technology makes it possible that the information collection device is connected to both ECU(Electronic Control Unit) which is the device for controlling engine, transmission, brake, air-bag, etc that are connected to in-vehicle network and OBD-II connector that is for data collection from various sensors. In addition, with a WiBro portable device (cell phone, PDA, PMP, UMPC, etc). equipped with a vehicle diagnostic programs, information for operation, failure and malfunction can be obtained and analyzed in real-time, and alarm is alerted when the vehicle is in abnormal status, which makes the early reactions to the status. Furthermore, the collected data can be sent through WiBro network to the server managed by the company specialized in managing the vehicles, thus the technology could help the drivers who have less knowledge about their auto-vehicles have safe and economic driving. There is always a possibility of malfunction due to various types of noise that are caused by wring-harness when the device is wired-connected. In this research, in order to overcome this problem, we propose a system configuration that can do monitoring and diagnosis with a device for collecting data from vehicle and a personal WiBro device. Also, we performed research on data acquisition and interlock for the system defined by the definition for information and data sharing platform.

Conceptual Design of Mechanical System for Recovery of Seabed-Deposited Hazardous and Noxious Substances Based on Performance Requirements (해저침적 HNS 회수용 기계장치의 성능요건 기반 개념설계)

  • Hwang, Ho-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.689-697
    • /
    • 2020
  • Hazardous and noxious substances (HNS) may cause maritime incidents during marine transportation, which are liable to lead to a large amount of spillage or discharge into the sea. The damage to the marine environment caused by the HNS spill or discharge is known to be much greater than the damage caused by oil spill. Particularly dangerous is HNS, which is deposited or buried in the seabed, as it can damage the organisms that live on, in, and near the bottom of the sea, the so-called "benthos," forming the benthic ecosystem. Therefore, it is vital that the HNS deposited on the seabed be recovered. In order to do so, procedures and equipment are required for accurate detection, stabilization treatment, and recovery of HNS in subsea sediment. Thus, when developing a mechanical recovery system, the performance requirements should be selected using performance indices, and the conceptual design of the mechanical recovery system should be based on performance requirements decided upon and selected in advance. Therefore, this study was conducted to arrive at a conceptual design for a mechanical recovery system for the recovery of HNS deposited on the seabed. In the design of the system, based on the fundamental scenario, the method of suction foundation with the function of self enclosing was adopted for recovering the HNS sediment in the subsea sediment. The mechanical recovery system comprises the suction foundation, pollution prevention, a pump system, control system, monitoring device, location information device, transfer device, and tanks. This conceptual design is expected to be reflected and used in the basic design of the components and shapes of the mechanical recovery system.

Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals (소동물 발광영상 측정을 위한 광학분자영상기기의 개발)

  • Lee, Byeong-Il;Kim, Hyeon-Sik;Jeong, Hye-Jin;Lee, Hyung-Jae;Moon, Seung-Min;Kwon, Seung-Young;Choi, Eun-Seo;Jeong, Shin-Young;Bom, Hee-Seung;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.344-351
    • /
    • 2009
  • Purpose: Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. Materials and Methods: In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. Results: We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. Conclusion: We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future.

Acceleration for Removing Sea-fog using Graphic Processors and Parallel Processing (그래픽 프로세서를 이용한 병렬연산 기반 해무 제거 고속화)

  • Kim, Young-doo;Kwak, Jae-min;Seo, Young-ho;Choi, Hyun-jun
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.5
    • /
    • pp.485-490
    • /
    • 2017
  • In this paper, we propose a technique for high speed removal of sea-fog using a graphic processor. This technique uses a host processor(CPU) and several graphics processors(GPU) capable of parallel processing to remove sea-fog from the input image. In the process of removing sea-fog, the dark channel extraction, the maximum brightness channel extraction, and the calculation of the transmission are performed by the host processor, and the process of refining the transmission by applying the bidirectional filter is performed in parallel through the graphic processor. To verify the proposed parallel processing method, three NVIDIA GTX 1070 GPUs were used to construct the verification environment. As a result, it takes about 140ms when implemented with one graphics processor, and 26ms when implemented using OpenMP and multiple GPGPUs. The proposed a parallel processing algorithm based on the graphics processor unit can be used for safe navigation, port control and monitoring system.

Development of Monitor Chamber Prototype and Basic Performance Testing (모니터 전리함 시작품 개발과 기초 성능 평가)

  • Lee, Mujin;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Rhee, Dong Joo;Kang, Sang Koo;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.99-105
    • /
    • 2015
  • The monitor chamber is a real time dosimetry device for the measurement and the control of radiation beam intensity of the linac system. The monitor chamber prototype was developed for monitoring and controlling radiation beam from the linac based radiation generator. The thin flexible printed circuit boards were used for electrodes of the two independent plane-parallel ionization chambers to minimize the attenuation of radiation beam. The dosimetric characteristics, saturation and linearity of the measured charge, were experimentally evaluated with the Co-60 gamma rays. The performance of the developed monitor chamber prototype was in an acceptable range and this study shows the possibility of the further development of the chamber with additional functions.

A study on liquid crystal-based electrical polarization control technology for polarized image monitoring device (편광 영상감시 장치를 위한 액정 기반 전기적 편광 조절 기술 연구)

  • Ahn, Hyeon-Sik;Lim, Seong-Min;Jang, Eun-Jeong;Choi, Yoonseuk
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.416-421
    • /
    • 2022
  • In this study, we present a fully automated system that combines camera technology with liquid crystal technology to create a polarization camera capable of detecting the partial linear polarization of light reflected from an object. The use of twisted nematic (TN) liquid crystals that electro-optically modulate the polarization plane of light eliminates the need to mechanically rotate the polarizing filter in front of the camera lens. Images obtained using these techniques are imaged by computer software. In addition, liquid crystal panels have been produced in a square shape, but many camera lenses are usually round, and lighting or other driving units are installed around the lens, so space is optimized through the application of a circular liquid crystal display. Through the development of this technology, an electrically switchable and space-optimized liquid crystal polarizer is developed.

Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations (지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정)

  • Kim, Seo-Jin;Kang, Ho-Seong;Son, Youn-Suk;Yoon, Sang-Lyeor;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, In-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.

Effectiveness of Obesity management programs: systematic review and meta-analysis (메타분석을 이용한 비만관리 프로그램의 효과분석)

  • Lee, Hyo-Young
    • Korean Journal of Health Education and Promotion
    • /
    • v.24 no.4
    • /
    • pp.131-147
    • /
    • 2007
  • As overweight and obese people have increased, obesity management programs have generated much concern in Korea. Many types of obesity management programs were operated, aimed at reducing weight, BMI, body fat percentage and so on. This study was conducted to review the features of studies in obesity management programs and systematically assess the effects which were published from 1995 to 2006 in Korea. Databases were systematically searched for published data in Korea. It were KISS (Korean studies information services system) and KERIS (Korean Education research information system), which were major literature search systems for all academic fields in Korea. Total 114 studies were initially identified, of which 21 satisfied our inclusion data. The effects of obesity management programs were assessed on the results in weight, BMI (body mass index), HDL (high density lipids), body fat percentage, self-efficacy. Effect size estimated on the equation of M1 - M2 / Sp, where M1 was mean of the experimental group, M2 was the mean of control group, and Sp was the pooled standard deviation. Magnitude of effect size was interpreted by using Cohen's definition. Cohen described small, medium, and large effect sizes as 0.2, 0.5, and 0.8 respectively. The studies about obesity management programs were the most published in 2005(26.1%). Obesity management programs were popularly operated as the type of 12 weeks intervention, exercise intervention(52.4%), quasi-experimental study(85.7%). Ten studies reported significant effects on weight, and nine studies reported significant effects on BMI and HDL. Only five and three studies reported significant effects on body fat percentage and self-efficacy respectively. The effects of each outcome were generally significant when the studies included these elements, intervention over 10 weeks, evaluation over 3 times, a comprehensive program (exercise, nutrition education, behavior modification) and reinforcing factors (self-monitoring, group discussion, one's goal setting, and etc.). Effective obesity management programs should contain these essential elements and objectives of obesity management programs must be set out evident at the beginning. The participants should be registered, educated and evaluated by continuous obesity management programs.

Development of Device Measuring Real-time Air Flow in Greenhouse (온실 공기유동 계측 시스템 개발)

  • Noh, Jae Seung;Kwon, Jinkyoung;Kim, Yu Yong
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.20-26
    • /
    • 2018
  • This study was conducted to develop a device for measuring the air flow by space variation through monitoring program, which acquires data by each point from each environmental sensor located in the greenhouse. The distribution of environmental factors(air temperature, humidity, wind speed, etc.) in the greenhouse is arranged at 12 points according to the spatial variation and a large number of measurement points (36 points in total) on the X, Y and Z axes were selected. Considering data loss and various greenhouse conditions, a bit rate was at 125kbit/s at low speed, so that the number of sensors can be expanded to 90 within greenhouse with dimensions of 100m by 100m. Those system programmed using MATLAB and LabVIEW was conducted to measure distributions of the air flow along the greenhouse in real time. It was also visualized interpolated the spatial distribution in the greenhouse. In order to verify the accuracy of CFD modeling and to improve the accuracy, it will compare the environmental variation such as air temperature, humidity, wind speed and $CO_2$ concentration in the greenhouse.