• Title/Summary/Keyword: Monitored data

Search Result 1,290, Processing Time 0.027 seconds

Internet of Things based Smart Energy Management for Smart Home

  • TASTAN, Mehmet
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.6
    • /
    • pp.2781-2798
    • /
    • 2019
  • Thanks to internet, as one of indispensable parts of our lives, many devices that we use in our daily lives like TV, air conditioner, refrigerator, washing machine, can be monitored and controlled remotely by becoming more intelligent via Internet of Things (IoT) technology. Smart Home applications as one of the elements of smart cities, are individually the most demanded application without question. In this study, Smart Energy Management (SEM) system, based on NodeMCU and Android, has been designed for SEM, which is a part of the smart home application. With this system, household energy consumption can be monitored in real time, as well as having the ability to record the data comprising of operation times and energy consumption information for each device. Additionally, it is ensured to meet the energy needs on a maximized level possible, during the hours when the energy costs are lower owing to the SEM system. The Android interface provides the users with the opportunity to monitor and change their electricity consumption habits in order to optimize the energy efficiency, along with the opportunity to draw up of a daily and weekly schedule.

Measuring displacements of a railroad bridge using DIC and accelerometers

  • Hoag, Adam;Hoult, Neil A.;Take, W. Andy;Moreu, Fernando;Le, Hoat;Tolikonda, Vamsi
    • Smart Structures and Systems
    • /
    • v.19 no.2
    • /
    • pp.225-236
    • /
    • 2017
  • Railroad bridges in North America are an integral but aging part of the railroad network and are typically only monitored using visual inspections. When quantitative information is required for assessment, railroads often monitor bridges using accelerometers. However without a sensor to directly measure displacements, it is difficult to interpret these results as they relate to bridge performance. Digital Image Correlation (DIC) is a non-contact sensor technology capable of directly measuring the displacement of any visible bridge component. In this research, a railroad bridge was monitored under load using DIC and accelerometers. DIC measurements are directly compared to serviceability limits and it is observed that the bridge is compliant. The accelerometer data is also used to calculate displacements which are compared to the DIC measurements to assess the accuracy of the accelerometer measurements. These measurements compared well for zero-mean lateral data, providing measurement redundancy and validation. The lateral displacements from both the accelerometers and DIC at the supports were then used to determine the source of lateral displacements within the support system.

Principal Component Analysis Based Method for a Fault Diagnosis Model DAMADICS Process (주성분 분석을 이용한 DAMADICS 공정의 이상진단 모델 개발)

  • Park, Jae Yeon;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.35-41
    • /
    • 2016
  • In order to guarantee the process safety and prevent accidents, the deviations from normal operating conditions should be monitored and their root causes have to be identified as soon as possible. The statistical theories-based method among various fault diagnosis methods has been gaining popularity, due to simplicity and quickness. However, according to fault magnitudes, the scalar value generated by statistical methods can be changed and this point can lead to produce wrong information. To solve this difficulty, this work employs PCA (Principal Component Analysis) based method with qualitative information. In the case study of our previous study, the number of assumed faults is much smaller than that of process variables. In the case study of this study, the number of predefined faults is 19, while that of process variables is 6. It means that a fault diagnosis becomes more difficult and it is really hard to isolate a single fault with a small number of variables. The PCA model is constructed under normal operation data in order to get a loading vector and the data set of assumed faulty conditions is applied with PCA model. The significant changes on PC (Principal Components) axes are monitored with CUSUM (Cumulative Sum Control Chart) and recorded to make the information, which can be used to identify the types of fault.

Performance Analysis of Hybrid Desiccant Chiller Based on Field Test (실증 실험을 통한 하이브리드 제습냉방 시스템의 성능 분석)

  • Ahn, Joon;Yun, Changho;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.621-627
    • /
    • 2013
  • Field tests of hybrid desiccant cooling systems were conducted from July to August 2011. Data were monitored and transferred in real time over the Internet. The monitored variableswere analyzed to determine the performance characteristics under outdoor conditions. A series of system simulations has been conducted for outdoor conditions of the field tests. The results agree well with the experimental data in general. The system performance has been shown to deteriorate for wetter conditions, as predicted by the simulation.

Performance Analysis of a BIPV Module Based on Round Robin Test of IEA PVPS Task 15 (국제에너지기구 태양광발전 협력사업의 공동실험 방법에 의한 건물일체형 태양광발전(BIPV) 모듈의 성능 평가 분석)

  • Kim, Jin Hee;Ahn, Jong Gwon;Kim, Jun Tae
    • Current Photovoltaic Research
    • /
    • v.8 no.2
    • /
    • pp.54-59
    • /
    • 2020
  • Within the IEA (International Energy Agency) PVPS (Photovoltaic Power System) Programme Task 15, 'Enabling Framework for the Acceleration of BIPV,' a round-robin action focusing on the performance of vertical BIPV elements as a facade in different climatic environments was performed. The performance of identical (both, in construction and bill of materials (BOM)) glass-to-glass c-Si BIPV elements was monitored at seven outdoor test sites in 6 different countries in Europe and Asia. In this work, the comprehensive results of the electrical and corresponding meteorological data will be presented and discussed. The monitored data were merged, processed, and filtered for further analysis. The analysis includes the chracteristics of the module temperatures and the in-plane irradiation at the outdoor test locations, mean daily PR per test module, time series of mean daily performance ratio coefficients, and monthly yield.

Development and evaluation of edge devices for injection molding monitoring (사출성형공정 모니터링용 엣지 디바이스 개발 및 평가)

  • Kim, Jong-Sun;Lee, Jun-Han
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.25-39
    • /
    • 2020
  • In this study, an edge device that monitors the injection molding process by measuring the mold vibration(acceleration) signal and the mold surface temperature was developed and evaluated its performance. During injection molding, signals of the injection start, V/P switchover, and packing end sections were obtained through the measurement of the mold vibration and the injection time and packing time were calculated by using the difference between the times of the sections. Then, the mold closed and mold open signals were obtained using a magnetic hall sensor, and cycle time was calculated by using the time difference between the mold closed time each process. As a result of evaluating the performance by comparing the process data monitored by the edge device with the shot data recorded on the injection molding machine, the cycle time, injection time, and packing time showed very small error of 0.70±0.38%, 1.40±1.17%, and 0.69±0.82%, respectively, and the values close to the actual were monitored and the accuracy and reliability of the edge device were confirmed. In addition, it was confirmed that the mold surface temperature measured by the edge device was similar to the actual mold surface temperature.

Reliability Tests on SpatiaLight's LCOS Microdisplays

  • Shin, Dong-Soo;Sun, Raymond;Jin, Michael
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.951-954
    • /
    • 2004
  • We report the recent reliability test results of SpatiaLight's liquid crystal on Silicon (LCOS) microdisplays. Two different types of reliability tests have been performed: 1) thermal and 2) thermal with high intensity UV light. Various important device parameters were regularly monitored including the contrast ratio, color uniformity, and switching time. The test data shows that there are no degradations that fail the pass criteria. Lifetime estimations are given from the test data.

  • PDF

Monitoring of itaconic acid production by a 2-dimensional fluorescence sensor

  • Jeong, Sang-Yun;Lee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.270-273
    • /
    • 2001
  • The fluorescence sensor is utilized to monitor the complex fluorescence patterns of intra- and extracellular components in cultivation processes. Especially biogenic fluorophores such as proteins and peptides (tryptophan, phenylalanine), coenzymes (FAD, NAD(P)H) and vitamins (riboflavin, pyridoxine) within cells are detected by a fluorescence sensor. In this work a 2-dimensional fluorescence sensor has been used to monitor a production process of itaconic acid by Aspergillus terreus and the on-line monitored spectra data can be con-elated to off-line data measured by a few methods.

  • PDF

Automatic Welding Carriage Control System with Self Diagnostic and Network functions (자가 고장진단 및 네트워크 기능을 보유한 자동용접 캐리지 제어 시스템)

  • 김종철;문형순;김종준;김용백;윤동섭;추정복
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.138-139
    • /
    • 2003
  • This paper describes the control system which was designed and implemented for a new automatic welding equipment. The system has the self diagnostic function which facilitates maintenance and repairs, and also has the network function via which the welding task data call be transmitted and the welding process data can be monitored.

  • PDF

Internet Monitoring of Wind-Photovoltaic Hybrid Generation System (풍력-태양광 복합발전 시스템의 인터넷 모니터링)

  • Yang, Si-Chang;Moon, Chae-Joo;Chang, Young-Hak;Soh, Soon-Yeol;Chung, Ji-Hyun;Kim, Eui-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.43-48
    • /
    • 2006
  • Recently, many researchers have shown great interest in wind-photovoltaic hybrid generation system which promotes electric power supply safely and progress of energy usage efficiently with complementary cooperation of a wind generation system and photovoltaic generation system. To use this hybrid generation system stably and effectively, we established a system which can acquire, analyse and save data and monitored remotely using internet. We constructed the signal conditioning circuit and used many kinds of converters to measure physical quantities such as wind velocity, intensity of illumination and temperature as well as many kinds of voltage and current for AC and DC. we acquired data from computer with data acquisition board, developed server program and client program which can download data that is monitored and saved in realtime at remote place. We analysed the measured data in relation to many conditions such as time and weather conditions.