• 제목/요약/키워드: Monitor Size

검색결과 422건 처리시간 0.027초

Comparison of particle size distribution and particle number concentration measured by APS 3321 and Dust Monitor 1.108 (APS 3321과 Dust Monitor 1.108을 이용한 입자 크기분포 및 수농도 측정결과 비교)

  • Lim, Kyoung-Soo;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • 제5권2호
    • /
    • pp.63-70
    • /
    • 2009
  • The size distribution and number concentration of atmospheric aerosol were measured and compared using APS 3321 and Dust Monitor 1.108. The particle size distribution and number concentration measured by two devices were also compared at a particle generation system of standard PSL and fly ash. The number concentration of atmospheric aerosol measured by APS was higher than that by Dust Monitor in particle size range of less than $3.0{\mu}m$, but there was good accordance between them in particle size range of over $3.0{\mu}m$. In the particle generation system of PSL and fly ash, different measurement results were shown because the particle concentration was higher than that of atmospheric aerosol. The number concentration measured by Dust Monitor was higher than that by APS in most particle size ranges. However, the peak concentration of PSL particles measured by Dust Monitor was lower than that by APS. The difference of the collection efficiency in a scrubber by APS and Dust Monitor measurement was less than 10%, but in the particle size of $1.5{\mu}m$, it was over 20%.

  • PDF

Affective Design for the Frame Size and Shape of Wide LCD Monitors (Wide LCD 모니터의 프레임 형태에 따른 감성 선호도 연구)

  • Lee, Han-Na;Jung, Eui-S.;Choe, Jae-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • 제28권4호
    • /
    • pp.61-69
    • /
    • 2009
  • With increasing needs for affective design, it became an essential part in a product development process to look up quantitative ergonomic data that reflects customers' preferences on design factors in various products. This study looked at wide LCD monitors and analyzed customers' affective preferences regarding monitor's bezel frame size and shape. The monitor's bezel frame depth, size and ratio were selected as independent variables among many design parameters. As dependent variables, customer's subjective preferences were measured. A statistical analysis revealed that monitor's bezel frame depth, size and ratio had significant effects on customer's preferences. Also, it was possible to find a different tendency on affective variables and their levels for 19" and 24" wide LCD monitors. In general, experiments revealed that customers reacted more sensitively in 24" wide LCD monitors to all variables. In 19" wide LCD monitors, only the lower frame bezel size had a significant effect, otherwise, lower, upper and side frame bezels appeared to be effective variables in 24" monitors. In order to reflect customer's affective preferences to new design of wide LCD monitors, this study is expected to provide quantitative ergonomic data and guidelines for the design of wide LCD monitor's bezel frame depth and size.

Development of a Real-time Monitoring Device for Measuring Particulate Matter

  • Kim, Dae Seong;Cho, Young Kuk;Yoon, Young Hun
    • Particle and aerosol research
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, we have developed a real-time monitoring device for measuring $PM_{10/2.5/1}$ of ambient aerosol particles. The real-time PM (Particulate Matter) monitor was based on the light scattering method and had 16 channels in particle size. The laboratory and field tests were carried out to evaluate the performance of the PM monitor developed. Arizona Road Dust particles ranging from diameter of 0.1 to $20{\mu}m$ were generated as test particles in the laboratory test. The field test was carried out at the Seoul Meteorological Observatory. We can obtain the particle size and number concentration (particle size distribution) only from the real-time PM monitor developed. Therefore, the average density of aerosol particles was used to obtain the PM data from the particle size distribution. The $PM_{10/2.5/1}$ results of the PM monitor were compared with the data of the Grimm Dust Monitor (Model 1.108) and a beta ray gauge (Thermo Fisher Scientific). As a result, it was shown that the $PM_{10/2.5/1}$ results obtained by the real-time PM monitor agreed well with the data of the reference devices, and overall, the real-time PM monitor could be used as a PM monitoring device for real-time monitoring of the ambient particles.

A Study on the Estimation of CCTV Monitor Size for School Crime Prevention (학교범죄예방을 위한 CCTV 모니터 크기 산정에 관한 연구)

  • Park, Sung-chul;Cho, Jin-il;Jung, Tae-hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • 제14권2호
    • /
    • pp.37-44
    • /
    • 2015
  • The purpose of this study is to propose the calculation model of CCTV monitor size for school. Literature review analyzed the concept and technical characteristics of CCTV system including equation of object size calculation. Case study showed that the sizes of CCTV monitors installed in the security offices of the six object schools were 19 inches on average. And the numbers of monitor screen partitions were at least 12 on average. Due to too many partitions in small monitors of approximately 19 inches, the faces of the objects of filming in each screen could not be properly identified. Experimental test presented that the vertical length of face image clearly recognized on the screen is at least 20mm. Based on the result, this paper developed the equation for calculating monitor size. Pilot test said that 27inch Monitor is needed for 4 screens. The practitioners of school districts and schools can make appropriate CCTV system environments considering the their own CCTV system conditions.

Effects of Small Monitor Size of DMB Phone and PMP on Viewers' Information Processing Process of Contents (DMB폰과 PMP의 작은 화면 사이즈 특성이 영상콘텐츠에 대한 정보처리과정에 미치는 영향)

  • Choi, I-Jung
    • The Journal of the Korea Contents Association
    • /
    • 제7권5호
    • /
    • pp.110-117
    • /
    • 2007
  • The recent developments of audio/video technology in the ubiquitous media have resulted in a variety of formal feature such as screen sizes for media and the new viewing environment can alter television viewers' experience of mediated communication. So the concern about formal feature of media itself is increasing in the recent media effects studies. From this point of view, this study is conducted to test the effect of the different monitor size of DMB Phone(2'1"), PMP(4'3") and PC monitor(19') on the viewers' memory and emotion of content by experimental research. The results showed that the effect by monitor size on the view's memory and emotion is significant. And watching moving image on a bigger monitor resulted in better memory of visual message elements contained in the content and more favorable emotion of the content.

Electronic Commercing And WEB Advertising Method Based on Dual LCD Monitor (두 화면 모니터 기반 전자상거래 및 광고 기법)

  • 이은석;임춘환;류재민
    • Journal of the Korea Computer Industry Society
    • /
    • 제2권12호
    • /
    • pp.1523-1532
    • /
    • 2001
  • The tophead monitor is a dual screen monitor that concludes auxiliary monitor with size 6.4 inch on the top of monitor. The bottom monitor screen provide previous function in the same way as before and the auxiliary monitor screen is arranged contents of internet advertising icon, banner advertising icon, moving picture screen, mail icon, etc. If you click contents, contents is moved peristaltically with the bottom monitor screen. The dual monitor screen is controlled by mouse and keyboard in the same way as before.

  • PDF

WEB Advertising and Electronic Commercing Method Based on Dual LCD Monitor (두 화면 모니터 기반 웹 광고 및 전자상거래 기법)

  • 이은석;임춘환;손영수;배상현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제5권7호
    • /
    • pp.1195-1203
    • /
    • 2001
  • The tophead monitor is a dual screen monitor that concludes auxiliary monitor with size 6.4 inch on the top of monitor. The bottom monitor screen provide previous function in the same way as before and the auxiliary monitor screen is arranged contents of internet advertising icon, banner advertising icon, moving picture screen, mail icon, etc. If you click contents, contents is moved peristaltically with the bottom monitor screen. The dual monitor screen is controlled by mouse and keyboard in the same way as before.

  • PDF

Diagnostic Instruments of PLS-II

  • Kim, Chang-Beom;Kim, Do-Tae;Choe, Jae-Yeong;Lee, Heung-Su;Park, Eung-Su;Sin, Seung-Hwan;Hwang, Jeong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.527-527
    • /
    • 2012
  • In the Pohang Light Source (PLS), a major upgrade (PLS-II) of existing machine had been performed in last 3 years. Big improvements in beam parameters are expected from this major upgrade and various diagnostic instruments were installed to measure them. These include beam position monitor, beam current monitor, tune monitor, scraper, beam loss monitor, photon beam monitor, beam size monitor, streak camera, and so on. In this work, we would like to briefly introduce diagnostic instruments of the PLS-II and present measurement results in the commissioning process of the PLS-II.

  • PDF

Development and Performance Evaluation of a Real-time PM Monitor based on Optical Scattering Method (광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가)

  • Kang, Doo Soo;Oh, Jung Eun;Lee, Sang Yul;Shin, Hee Joon;Bong, Ha Kyung;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • 제14권4호
    • /
    • pp.107-119
    • /
    • 2018
  • In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.

Performance Characteristics of In-Situ Particle Monitors at Sub-Atmospheric Pressure (감압상태에서의 In-Situ Particle Monitor의 성능특성)

  • Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제22권11호
    • /
    • pp.1564-1570
    • /
    • 1998
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at subatmospheric pressures has been studied. We created uniform upstream conditions of particle concentration and measured the detection efficiency, the lower detection limit, and the size response of the ISPM using uniform sized methylene blue aerosol particles. The effect of particle size, particle velocity, particle concentration, and system pressure on the detection efficiency was examined. Results show that the detection efficiency of the ISPM decreases with decreasing chamber pressure, and with increasing mass flow rate. The lower detection limit of the ISPM, determined at 50 % of the measured maximum detection efficiency, was found to be about $0.15{\sim}0.2{\mu}m$, which is similar to the minimum detectable size of $0.17{\mu}$ given by the manufacturer.