• Title/Summary/Keyword: Monitering system

Search Result 138, Processing Time 0.024 seconds

Power Signal Monitering System with Compression Storage and Reconstruction (압축 저장 및 복원기능을 가지는 전력신호 모니터링 시스템)

  • Bae, Hyeon-Deok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.148-154
    • /
    • 2016
  • In recent year, the interests of PQ is increase due to the increasing of non-linear load and distributed power sources in power system. For the parameters detection and feature extraction of PQ, and the PQ improvement method, continuous power signal monitering is needed. In this paper, the power signal compression and reconstruction method is suggested for power signal monitering. The power signal is compressed using DCT that has good compression performance, and the compressed signal is reconstructed through IDCT. And for the higher compression rate, DCT coefficients are arranged by magnitude in compression process, and in recouction process DCT coefficients are rearranged to original frequency position. The synthesized signal according to the IEC standard is used used in compression and reconstruction simulations. The performances of the proposed method are verified by comparing the error between synthesized signal and reconstructed signal.

A Study on the Energy Self-Sufficiency of KIER Zero Energy Solar House II (제로에너지 솔라하우스(KIER ZESH-II)의 에너지 자립도에 대한 연구)

  • Jeong, Seonyeong;Baek, Namchoon;Yoo, Changkyoon;Yoon, Jongho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.199.1-199.1
    • /
    • 2010
  • The purpose of this study is on the thermal performance evaluation of KIER Zero Energy Solar House-II, called ZeSH-II which can be sustained with the support of a very few energy. This ZeSH-II was designed and constructed in the end of 2009 to develop for the goal of 70% self-sufficiency. Several key technologies like as the super insulation, high performance window, wast heat recovery system as well as solar power and thermal system and geo-source heat pump wear used for this ZeSH-II. The monitering of ZeSH-II was conducted for six months from November 2009 to April 2010. The monthly energy consumption was calculated based on the monitering results. As a result, the ZeSH-II shows that the energy self-sufficiency during six months(from oct. to apr.) is about 80% which is higher than that of the target.

  • PDF

Implementation of the Disaster Monitering System with PLC/CDMA Environments (PLC/CDMA 환경에서의 재난 감시 시스템 구현)

  • Park, Sang-Hwan;Kim, In-Min;Yoon, Seon-Tae;Park, Ki-Won;Go, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.824-830
    • /
    • 2010
  • PLC_Zigbee system, implemented in a previous study, uses ZigBee Node based on PLC (Power Line Communication). The weak point of the system is that the long distance powerline communication and PLC is impossible to use in the areas where the powerline is not installed. In this paper, we added CDMA (Code Division Multiple Access) module using a data transfer method of SMS (Short Message Service) and XBee of WSN (Wireless Sensor Network) module to the previous system, and got around the restriction of place and environment of PLC system through the interfacing of each communication media. We, thus, implemented a wide range of real monitoring system.

Prediction of Wildfire Spread and Propagation Algorithm for Disaster Area (재난 재해 지역의 산불 확산경로와 이동속도 예측 알고리즘)

  • Koo, Nam-kyoung;Lee, Kang-whan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1581-1586
    • /
    • 2016
  • In this paper, we propose a central disaster monitoring system of the forest fire. This system provides the safe-zone and detection to reduce the suppression efforts. In existing system, it has a few providing the predicting of wildfire spread model and speed through topography, weather, fuel factor. This paper focus on the forest fire diffusion model and predictions of the path identified to ensure the safe zone. Also we have considering the forest fire of moving direction and speed for fire suppression and monitering. The proposed algorithm could provide the technique to analyze the attribute information that temperature, wind, smoke measured over time. This proposed central observing monitoring system could provide the moving direction of spred out forecast wildfire. This observing and monitering system analyze and simulation for the moving speed and direction forest fire, it could be able to predict and training the forest fire fighters in a given environment.

Implementation of Driver Fatigue Monitoring System (운전자 졸음 인식 시스템 구현)

  • Choi, Jin-Mo;Song, Hyok;Park, Sang-Hyun;Lee, Chul-Dong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.711-720
    • /
    • 2012
  • In this paper, we introduce the implementation of driver fatigue monitering system and its result. Input video device is selected commercially available web-cam camera. Haar transform is used to face detection and adopted illumination normalization is used for arbitrary illumination conditions. Facial image through illumination normalization is extracted using Haar face features easily. Eye candidate area through illumination normalization can be reduced by anthropometric measurement and eye detection is performed by PCA and Circle Mask mixture model. This methods achieve robust eye detection on arbitrary illumination changing conditions. Drowsiness state is determined by the level on illumination normalize eye images by a simple calculation. Our system alarms and operates seatbelt on vibration through controller area network(CAN) when the driver's doze level is detected. Our algorithm is implemented with low computation complexity and high recognition rate. We achieve 97% of correct detection rate through in-car environment experiments.

Development of the Multichannel Vibration Monitoring System (다채널 진동 모니터링 장치 개발)

  • Hong, Tae-Yong;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.671-676
    • /
    • 2016
  • This study is about design for the Rotational Instrument of the Industry factory which is used management safety and maintenance. We developed the multichannel vibration monitering system of the self-diagnosis for middle level CMS(Condition Monitoring System) market, and that system are new features to the expandability and flexibility. Normally one channel is used for treating one signal, but developed instrument can treat four channel with one signal processing card. One rack have redundant power supply and displace and it can check vibration measurement value in field without computer. Bearing fault detection is fundamental of vibration surveillance, but sometimes can not check with vibration velocity and acceleration. So it need the filtering and the amplitude modulation on the acceleration enveloping technology when irregular vibration is happened. We developed the vibration analysis instrument which is applied such technology. And the development prototype shows activated within the vibration error limit.

The Web Viewer System Development of Real-Time Patient Monitering using HL7(Healthy Level Seven) Protocol (HL7(Healthy Level Seven) 프로토콜을 이용한 실시간 환자 모니터링 웹 뷰어시스템 개발)

  • Kim, Gwang-Jun;Lim, Se-Jung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.3
    • /
    • pp.546-555
    • /
    • 2009
  • HL7 is well-known standard protocol for text data generated in hospital information systems. Vital sign information web viewer systems is also the standard protocol for medical image and transfer. In this paper, we have to design to obtain useful vital sign information, which is generated at data receiver modulor of HIS, that is offered by the central monitor. Vital sign informations of central monitor is composed of the row data of several bedsite patient monitors. We are willing to maintain vital sign information of real time and continuity that is generated from the bedsite patient monitor. It is able to apply to remote medical examination and treatment. we proposed integration method between vital sign database systems and hospital information systems. Through the proper exchange and management of patient vital sign information, real time vital sign information management will offer better workflow to all hospital employee.

The implementation of OSCi bundle for digital convergence based on middleware of UPnP (UPnP 미들웨어 기반 디지털 컨버전스를 위한 OSGi 번들 개발)

  • Jun, Jaeh-Yan;Kang, Sung-In;Kim, Gwan-Hyung;Choi, Sung-Wook;Kwon, Oh-Hyun;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.105-108
    • /
    • 2007
  • In this paper, we have developed a UPnP-OSGi Bundle for digital convergence based on UPnP middleware. UPnP-OSGi bundle is demanded sustaining realtime monitering system based on UPnP middleware that is possible multimedia ability of a piece with a multiplicity of service and joint user data , service lifecycle , management division service for home network system offered convergence service. This bundle is possible a multiplicity of control and monitering service segmentation so develop a multiplicity of service is easy. and provide zero-configuration system.

  • PDF