• Title/Summary/Keyword: Molecular imaging

Search Result 830, Processing Time 0.031 seconds

Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics (미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계)

  • Lee, B.K.;Khaliq, A.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.55-61
    • /
    • 2022
  • There is a major interest in diagnostic technology for multiple cancers worldwide. In order to reduce the difficulty of cancer diagnosis, a liquid biopsy technology based on a microfluidic device using trace amounts of biofluids such as blood is being studied. And optical biosensing, which measures the concentration of analytes through fluorescence imaging using biofluids, requires various strategies to improve sensitivity, and specialists and equipment are needed to carry out these strategies. This leads to an increase in diagnostic and production costs, and it is necessary to develop a technology to solve this problem. In this paper, we design and propose a fluorescent multi-cancer diagnostic sensing platform structure that implements passive self-separation technology and molecular recognition activation functions by fluid mixing, only with the geometry and microfluidic phenomena of microchannels based on self-driven flow by capillary force. In order to check the parameters affecting the performance of the plasma separation part of the designed sensor, the hydrodynamic diameter of the channel and the viscosity of the fluid were set as variables to confirm the formation of plasma separation flow through simulation. And finally, we propose an optimal sensor platform structure.

Colloidal Optics and Photonics: Photonic Crystals, Plasmonics, and Metamaterials

  • Jaewon Lee;Seungwoo Lee
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.608-637
    • /
    • 2023
  • The initial motivation in colloid science and engineering was driven by the fact that colloids can serve as excellent models to study atomic and molecular behavior at the mesoscale or microscale. The thermal behaviors of actual atoms and molecules are similar to those of colloids at the mesoscale or microscale, with the primary distinction being the slower dynamics of the latter. While atoms and molecules are challenging to observe directly in situ, colloidal motions can be easily monitored in situ using simple and versatile optical microscopic imaging. This foundational approach in colloid research persisted until the 1980s, and began to be extensively implemented in optics and photonics research in the 1990s. This shift in research direction was brought by an interplay of several factors. In 1987, Yablonovitch and John modernized the concept of photonic crystals (initially conceptualized by Lord Rayleigh in 1887). Around this time, mesoscale dielectric colloids, which were predominantly in a suspended state, began to be self-assembled into three-dimensional (3D) crystals. For photonic crystals operating at optical frequencies (visible to near-infrared), mesoscale crystal units are needed. At that time, no manufacturing process could achieve this, except through colloidal self-assembly. This convergence of the thirst for advances in optics and photonics and the interest in the expanding field of colloids led to a significant shift in the research paradigm of colloids. Initially limited to polymers and ceramics, colloidal elements subsequently expanded to include semiconductors, metals, and DNA after the year 2000. As a result, the application of colloids extended beyond dielectric-based photonic crystals to encompass plasmonics, metamaterials, and metasurfaces, shaping the present field of colloidal optics and photonics. In this review we aim to introduce the research trajectory of colloidal optics and photonics over the past three decades; To elucidate the utility of colloids in photonic crystals, plasmonics, and metamaterials; And to present the challenges that must be overcome and potential research prospects for the future.

Safety of Administering Intravenous CT Contrast Agents Repeatedly or Using Both CT and MRI Contrast Agents on the Same Day: An Animal Study

  • Heejin Bae;Hyewon Oh;Ga Bin Park;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • v.25 no.3
    • /
    • pp.257-266
    • /
    • 2024
  • Objective: To investigate molecular and functional consequences of additional exposures to iodine- or gadolinium-based contrast agents within 24 hours from the initial intravenous administration of iodine-based contrast agents through an animal study. Materials and Methods: Fifty-six Sprague-Dawley male rats were equally divided into eight groups: negative control, positive control (PC) with single-dose administration of CT contrast agent, and additional administration of either CT or MR contrast agents 2, 4, or 24 hours from initial CT contrast agent injection. A 12 µL/g of iodinated contrast agent or a 0.47 µL/g of gadolinium-based contrast agent were injected into the tail vein. Serum levels of blood urea nitrogen, creatinine, cystatin C (Cys C), and malondialdehyde (MDA) were measured. mRNA and protein levels of kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL) were evaluated. Results: Levels of serum creatinine (SCr) were significantly higher in repeated CT contrast agent injection groups than in PC (0.21 ± 0.02 mg/dL for PC; 0.40 ± 0.02, 0.34 ± 0.03, and 0.41 ± 0.10 mg/dL for 2-, 4-, and 24-hour interval groups, respectively; P < 0.001). There was no significant difference in the average Cys C and MDA levels between PC and repeated CT contrast agent injection groups (Cys C, P = 0.256-0.362; MDA, P > 0.99). Additional doses of MR contrast agent did not make significant changes compared to PC in SCr (P > 0.99), Cys C (P = 0.262), and MDA (P = 0.139-0.771) levels. mRNA and protein levels of KIM-1 and NGAL were not significantly different among additional CT or MR contrast agent groups (P > 0.05). Conclusion: A sufficient time interval, probably more than 24 hours, between repeated contrast-enhanced CT examinations may be necessary to avoid deterioration in renal function. However, conducting contrast-enhanced MRI on the same day as contrast-enhanced CT may not induce clinically significant kidney injury.

Enhancement of aberrantly modified integrin-mediated cell motility in multicellular tumor spheroids

  • BYOUNGJAE KIM;NU-RI IM;TAESEOK DANIEL YANG;JIAN KIM;KWANG-YOON JUNG;TAE HOON KIM;SEUNG-KUK BAEK
    • International Journal of Oncology
    • /
    • v.56 no.6
    • /
    • pp.1490-1498
    • /
    • 2020
  • Multicellular tumor spheroids (MTSs) of malignant cells can display cell-cell and cell-matrix interactions, different from monolayer cultures. The objective of the present study was to examine difference in intercellular and cell-matrix interaction between monolayered cultures and spheroid cultures. Expression levels of cell adhesion molecules (CAMs) and epithelial-mesenchymal transition (EMT) signaling molecules in monolayered cells and MTS cells were compared. The motility of single cells dispersed from each culture was evaluated using a live-cell imaging device. The effect of an E-cadherin neutralizing antibody, DECMA, was also compared between the two cultures. Among various CAMs, only E-cadherin was increased in MTSs. The motility of single cells dispersed from MTSs was higher than that from monolayered cells. Compared with monolayered cells, the molecular weight (MW) of β1 integrin was decreased during MTS formation, particularly during the early stage. This notable reduction was maintained when DECMA was used to treat MTSs. Additionally, the expression levels of the EMT signaling molecules Snail and ILK increased more in MTSs than in monolayered cells. The blocking of E-cadherin elicited increased expression levels of EMT molecules and cellular motility only in MTSs. In conclusion, the alteration of E-cadherin expression and presence of low-MW β1 integrin in MTS may enhance cell motility via the upregulation of EMT signaling molecules that may be intensified by blocking E-cadherin.

Association between KCNQ2, TCF4 and RGS18 polymorphisms and silent brain infarction based on whole-exome sequencing

  • Jung Oh Kim;Kee Ook Lee;Hyun Woo Kim;Han Sung Park;Jinkwon Kim;Jung Hoon Sung;Doyeun Oh;Ok Joon Kim;Nam Keun Kim
    • Molecular Medicine Reports
    • /
    • v.21 no.4
    • /
    • pp.1973-1983
    • /
    • 2020
  • Silent brain infarction (SBI) is a cerebral infarction identified through brain imaging. In particular, studies have shown that the presence of SBI in elderly patients increases their risk of cognitive dysfunction, impairment and dementia. However, little research has been published on the relevance of SBI to these risks for the Korean population. The association between potassium voltage-gated channel subfamily Q member 2 (KCNQ2), transcription factor 4 (TCF4) and regulator of G-protein signaling 18 (RGS18) genotypes and SBI were investigated using whole-exome sequencing and PCR restriction fragment length polymorphism (RFLP) analysis. The study population included 407 patients with SBI (171 males) and 401 control subjects (172 males). Genotyping was performed using PCR RFLP. Interestingly, TCF4 rs9957668T>C polymorphisms were associated with SBI prevalence [TT vs. CC: adjusted odds ratio (AOR), 1.815, 95% confidence intervals (CI), 1.202-2.740; TT vs. TC+CC: AOR, 1.492, 95% CI, 1.066-2.088; TT+TC vs. CC: AOR, 1.454, 95% CI, 1.045-2.203]. The combination of KCNQ2 rs73146513A>G and TCF4 rs9957668T>C genotypes was associated with increasing SBI prevalence (AG/CC: AOR, 3.719, 95% CI, 1.766-7.833; AA/CC: AOR, 3.201, 95% CI, 1.387-7.387). The present study showed that TCF4 rs9957668T>C polymorphisms may be risk factors for SBI. Therefore, the TCF4 rs9957668T>C polymorphism may serve as a biomarker for increased risk of SBI in the Korean population.

Evaluation of Myocardial Oxygen Consumption with $^{11}C$-Acetate and 3D PET/CT: By Applying Recirculation Correction Method and Modified One-Compartmental Tracer Kinetic Modeling ($^{11}C$-Acetate와 3차원 PET/CT를 이용한 심근의 산소 소모량 평가: 재순환 교정법 및 수정 단일구획 추적자 동적 모델 적용)

  • Chun, In-Kook;Hwang, Kyung-Hoon;Lee, Sang-Yoon;Kim, Jin-Su;Lee, Jae-Sung;Shin, Hee-Won;Lee, Min-Kyung;Yoon, Min-Ki;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.275-284
    • /
    • 2008
  • Purpose: We intended to evaluate myocardial oxygen consumption ($MVO_2)$ by applying recirculation correction and modified one-compartment model to have a reference range of $MVO_2$ in normal young population and to reveal the effect of recirculation on time-activity curve (TAC). Materials and Methods: In nine normal male volunteers with mean age of $26.3{\pm}4.0$, $MVO_2$ was estimated with 925 MBq (25mCi) of $^{11}C$-Acetate (Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Korea) and PET/CT (Biograph 6, Siemens Medical Solution, Germany). Analysis software such as $MATLAB^{(R)}$ v7.1 (Mathworks, Inc., United States), $Excel^{(R)}$ 2007 (Microsoft, United States), and $SPSS^{(R)}$ v12.0 (Apache Software Foundation, United States) were used. Twenty three frames were of $12{\times}10$, $5{\times}60$, $3{\times}120$, $2{\times}300's$ duration, respectively. The modified one-compartmental model and the recirculation correction method were applied. Statistical analysis was performed by using Test of Normality, ANOVA and Post-Hoc (Scheffe's) analysis, and p-value less than 0.05 was considered as significant. Results: The normal reference ranges of $MVO_2$ were presented as $3.18-4.64\;{\times}\;10^{-4}\;ml/g/sec$, $1.91-3.94\;{\times}\;10^{-4}\;ml/g/sec$, $4.31-6.40\;{\times}\;10^{-4}\;ml/g/sec$, $2.84-4.53\;{\times}\;10^{-4}\;ml/g/sec$ and $3.42-5.00\;{\times}\;10^{-4}\;ml/g/sec$ in the septum, the inferior wall, the lateral wall, the anterior wall and the entire wall, respectively. In addition, it was noted that the dual exponentiality of the clearance curve is due to the recirculation effect and that the characteristic of the curve is essentially mono-exponential. Conclusion: $^{11}C$-Acetate is a radiotracer worthwhile to assess $MVO_2$. Re-circulated $^{11}C$ can influence TAC of $^{11}C$ in myocadia and so the recirculation correction must be considered when measuring $MVO_2$.

Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET ($^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계)

  • Lee, Byeong-Il;Kim, Kye-Hun;Kim, Jung-Young;Kim, Su-Jin;Lee, Jae-Sung;Min, Jung-Joon;Song, Ho-Chun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • Purpose: $^{13}N$-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Methods: Twelve patients (11 males, 1 female, $57.9{\pm}8.6$ years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: $5\;sec\;{\times}\;12,\;10\;sec\;{\times}\;6,\;20\;sec\;{\times}\;3,\;and\;30\;sec\;{\times}\;6$) were initiated simultaneously with bolus injection of 11 MBq/kg $^{13}N-ammonia$ to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. Results: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Conclusions: Corrected and translated MPS as its characteristics using $^{13}N$-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.

Diagnostic Role of F-18 FDG PET/CT in the Follow-up of Patients with Colorectal Cancer: Comparison with Serum CEA, CA 19-9 Levels and Computed Tomography (대장암 치료 후 추적 검사로서 F-18 FDG PET/CT의 역할: 혈청 CEA, CA 19-9 및 Computed Tomography와의 진단 성능 비교)

  • Kang, Sung-Min;Song, Bong-Il;Lee, Hong-Je;Seo, Ji-Hyoung;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Choi, Kyu-Suk;Jun, Soo-Han
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.120-128
    • /
    • 2009
  • Purpose: Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of CEA, CA 19-9, CT and PET/CT has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to compare the diagnostic ability of PET/CT, tumor marker and CT for recurrence in colorectal cancer patients after treatment. Materials and Methods: F-18 FDG PET/CT imaging was performed in 189 colorectal cancer patients who underwent curative surgical resection and/or chemotherapy. Measurement of serum levels of CEA, CA 19-9 and CT imaging were performed within 2 months of PET/CT examination. Final diagnosis of recurrence was made by biopsy, radiologic studies or clinical follow-up for 6 months after each study. Results: Overall sensitivity, specificity of PET/CT was 94.7%, 91.1%, while those of serum CEA were 44.7% and 97.3%, respectively. Sensitivity and specificity were 94.2%, 90.4% for PET/CT and better than those of combined CEA and CA 19-9 measurement(52.1%, 88.5%) in 174 patients measured available both CEA and CA 19-9 data. In 115 patients with both tumor markers and CT images available, PET/CT showed similar sensitivity but higher specificity(92.9%, 91.3%) compared to combination of tumor markers and CT images(92.9%, 74.1%). Conclusion: PET/CT was superior for detection of recurred colorectal cancer patients compared with both CEA, CA 19-9, and even with combination of both tumor markers and CT. Therefore PET/CT could be used as a routine surveillance examination to detect recurrence or metastasis of colorectal cancer.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

The Clinical Utility of Rectal Gas Distension F-18 FDG PET/CT (공기주입 직장 확장 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.565-571
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the clinical value of rectal gas distension F-18 FDG PET/CT imaging for the differentiation of the rectal focal uptake lesions. Materials and Methods: Twenty four patients (M:F=11:13, Age $62.8{\pm}12.4$ years) underwent rectal gas distension F-18 FDG PET/CT, prospectively: initial image at 50-60 min after the intravenous injection of F-18 FDG and rectal distension image after the infusion of air through the anus. Focally increased uptake lesions on initial images but disappeared on rectal distension images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on rectal distension images, colonoscopy and histopathologic examination were performed. Results: Among the 24 patients, 27 lesions of focal rectal uptake were detected on initial images of F-18 FDG PET/CT. Of these, 7 lesions were able to judge with physiological uptake because the focal increased uptake disappeared from rectal distension image. Remaining 3 lesions were non-rectal lesions (2 lesions: rectovesical space, 1 lesion: uterine myoma). Among 17 lesions which was showed persistent increased uptake in rectal distension image, 15 lesions were confirmed as the malignant tumor (SUVmax=$15.9{\pm}6.8$) and 2 lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Conclusion: The rectal distension F-18 FDG PET/CT imaging could be an important noninvasive method for the differentiation of malignant and benign focal rectal uptake lesions including physiologic uptake.