• Title/Summary/Keyword: Molecular flow range

Search Result 86, Processing Time 0.034 seconds

Growth behavior on initial layer of ZnO:P layers grown by magnetron sputtering with controlled by $O_2$ partial pressure

  • Kim, Yeong-Lee;An, Cheol-Hyeon;Bae, Yeong-Suk;Kim, Dong-Chan;Jo, Hyeong-Gyun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.28.1-28.1
    • /
    • 2009
  • The superior properties of ZnO such as high exciton binding energy, high thermal and chemical stability, low growth temperature and possibility of wet etching process in ZnO have great interest for applications ranging from optoelectronics to chemical sensor. Particularly, vertically well-aligned ZnO nanorods on large areas with good optical and structural properties are of special interest for the fabrication of electronic and optical nanodevices. Currently, low-dimensional ZnO is synthesized by metal-organic chemical vapor deposition (MOCVD), molecular beam epitaxy (MBE), thermal evaporation, and sol.gel growth. Recently, our group has been reported about achievement the growth of Ga-doped ZnO nanorods using ZnO seed layer on p-type Si substrate by RF magnetron sputtering system at high rf power and high growth temperature. However, the crystallinity of nanorods deteriorates due to lattice mismatch between nanorods and Si substrate. Also, in the growth of oxide using sputtering, the oxygen flow ratio relative to argon gas flow is an important growth parameter and significantly affects the structural properties. In this study, Phosphorus (P) doped ZnO nanorods were grown on c-sapphire substrates without seed layer by radio frequency magnetron sputtering with various argon/oxygen gas ratios. The layer change films into nanorods with decreasing oxygen partial pressure. The diameter and length of vertically well-aligned on the c-sapphire substrate are in the range of 51-103 nm and about 725 nm, respectively. The photoluminescence spectra of the nanorods are dominated by intense near band-edge emission with weak deep-level emission.

  • PDF

Effect of spinning parameters of polyethersulfone based hollow fiber membranes on morphological and mechanical properties

  • Tewfik, Shadia R.;Sorour, Mohamed H.;Shaalan, Hayam F.;Hani, Heba A.
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.43-51
    • /
    • 2018
  • Hollow fiber (HF) membranes are gaining wide interest over flat membranes due to their compaction and high area to surface volume ratio. This work addresses the fabrication of HF from polysulfone (PS) and polyethersulfone (PES) using N-methylpyrrolidone (NMP) as solvent in addition to other additives to achieve desired characteristics. The semi-pilot spinning system includes jacketed vessel, four spinneret block, coagulation and washing baths in addition to dryer and winder. Different parameters affecting dry-wet spinning phase inversion process were investigated. Dope compositions of PES, NMP and polyvinyl pyrrolidone (PVP) of varying molecular weights as additive were addressed. Some critical parameters of importance were also investigated. Those include dope flow rate, air gap, coagulation & washing baths and drying temperatures. The measured dope viscosity was in the range from 1.7 to 36.5 Pa.s. Air gap distance was adjusted from 20 to 45 cm and coagulation bath temperature from 20 to $46^{\circ}C$. The HF membranes were characterized by scanning electron microscope (SEM), atomic force microscope (AFM) and mechanical properties. Results indicated prevalence of finger like structure and average surface roughness from about 29 to 78.3 nm. Profile of stress strain characteristics revealed suitability of the fibers for downstream interventions for fabrication of thin film composite membrane. Different empirical correlations were formulated which enable deeper understanding of the interaction of the above mentioned variables. Data of pure water permeability (PWP) confirmed that the fabricated samples fall within the microfiltration (MF)-ultrafiltration (UF) range of membrane separation.

Simultaneous Determination of Asperosaponins and Iridoid Glycosides from Dipsaci Radix by Using LC-ESI-MS Spectrometry (속단(Dipsaci Radix) 중 Asperosaponins 및 Iridoid glycosides의 LC-ESI-MS에 의한 동시분석)

  • Cho, Hwang-Eui;Son, In-Seop;Kim, Sun-Cheun;Son, Kun-Ho;Woo, Mi-Hee;Moon, Dong-Cheul
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.2
    • /
    • pp.137-146
    • /
    • 2012
  • Dipsaci Radix (Dipsacaceae) has been used as a tonic, an analgesic, anti-inflammatory and anti-complement agents in traditional herbal medicine for the therapy of low back pain, knee pain, rheumatic arthritis, traumatic hematoma, and bone fractures. A high-performance liquid chromatography-electrospray ionization-mass spectrometric method (HPLC-ESI-MS) was developed for the simultaneous quantitation method of the five compounds from the herbal drug: asperosaponin VI and asperosaponin XII (terpene glycosides), sweroside, loganin and dipsacus A(iridoid glycosides). HPLC separation of the analytes was achieved on a C18 column ($150{\times}2.0$ mm i.d., 5 ${\mu}m$) using the aqueous methanol containing 5 mM ammonium acetate with gradient flow of the mobile phase. Detection of the analytes was performed by positive ion electrospray ionization, and selected ion monitoring was used for data acquisition using m/z corresponding molecular adduct ion, $[M+NH_4]^+$ and $[M+H]^+$. Calibration graphs showed good linearity ($r^2$=0.9997) over the wide range of the analytes; intra- and inter-day precisions (RSD, %) were within 9.1% and the accuracy between 94.0-111.0%. Recoveries of the analytes through the assay procedure were in the range of 93.7-110.8%. Analytical results of the herbal drugs of Dipsaci Radix (17 samples) show wide distribution of the five marker compounds and clear difference of the species from Phlomidis Radix (4 samples). The developed method would provide a practical guide for the quality control of the herbal drug.

Optical Emission Spectra of Oxygen Plasma Produced by Radio-Frequency Plasma (RF 플라즈마에 의해 생성된 산소 플라즈마의 발광 스펙트럼)

  • Kim, Do-Yeob;Kim, Min-Su;Kim, Tae-Hoon;Kim, Ghun-Sik;Choi, Hyun-Young;Cho, Min-Young;Jeon, Su-Min;Park, Sung-Dong;Kim, Jin-Ha;Kim, Eun-Do;Hwang, Do-Weon;Lee, Jae-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.102-107
    • /
    • 2009
  • We investigated optical emission of oxygen plasma discharged by 13.56 MHz radio frequency (rf) by using optical emission spectroscopy (OES). Experimental measurement is done at a range of oxygen flow rate of 1$\sim$20 seem, rf power of 25$\sim$250 W, and orifice 3 and 5 mm in diameter. When oxygen plasma was generated, typical emission spectra for oxygen plasma were observed regardless of diameter of orifice. Strong atomic emission lines are observe at 776.8 an 843.9 nm, corresponding to the $3p^{5}P-3s^{5}S^{0}$ and $3p^{3}P-3s^{3}S^{0}$ transitions, respectively. The emission intensity of line at 776.8 and 843.9 nm increased with increasing the oxygen flow rate and rf power. The increasing rate of emission intensity of 776.8 nm line was larger than that of 843.9 nm line. When the diameter of orifice was 3 mm, the oxygen plasma was more stably generated than orifice 5 mm in diameter.

Simultaneous Analyses for Trace Multi-Odorous and Volatile Organic Compounds in Gas using a Triple-bed Adsorbent Tube (Triple-bed Adsorbent Tube를 이용한 가스상 극미량 복합 악취 및 휘발성 유기화합물의 동시 분석)

  • Seo, Yong Soo;Lee, Jea Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.244-252
    • /
    • 2010
  • The objective of this study is to assess feasibility of simultaneous analysis for trace multi-components odorous and volatile organic compounds using a Triple-bed adsorbent tube with a thermal desorber and GC-MS. Triple-bed adsorbent tube is 3 bed packed Tenax-TA with small amount of Carbopack B and Carbosieve SIII in order of adsorption strength in a tube. The operating conditions of GC-MS was possibly able to and effectively detect high volatile and low molecular weight compounds at the mass range of 20~350 m/z using a below impurity 1ppm of Helium carrier gas, of which quantitatively analyzed by target ion extracts. According to the experiment, $C_1{\sim}C_5$ of 14 components; sulfur containing compounds(2), ketones(2), alcohols(4) and aldehydes(6) were simultaneously analyzed with recoveries of 99%, and good repeatability and linearity. High volatile and low molecular weight compounds such as methyl alcohol and acetaldehyde can be safely quantified with high recovery at a condition of 50mL/min of flow rate, below 2L of adsorption volume, and 45% of relative humidity. Target ion extract can also simultaneously quantify multicomponents with odorous and volatile organic compounds in an occasion of piled up two peaks.

Measurement of Shunt Amount Using Radionuclide Angiocardiography: Accuracy According to Level of Shunt and Associated Lesion (방사성 동위원소 심혈관 조영술을 이용한 단락량 측정법: 정확성에 영향을 미치는 인자)

  • Kim, Yang-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.200-204
    • /
    • 2006
  • Purpose: Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. Materials and Methods: We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. Results: The mean Qp/Qs was $1.83{\pm}0.50$ by radionuclide, and $1.74{\pm}0.51$ by oxymetry. The overall correlation coefficient was 0.86(p<0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44, and Bland-Altman range was 1.51, 0.74, 0.96, 1.57, and 1.50, respectively. Conclusion: There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

Dry Etching of GaAs and AlGaAs in Diffuion Pump-Based Capacitively Coupled BCl3 Plasmas (확산펌프 기반의 BCl3 축전결합 플라즈마를 이용한 GaAs와 AlGaAs의 건식 식각)

  • Lee, S.H.;Park, J.H.;Noh, H.S.;Choi, K.H.;Song, H.J.;Cho, G.S.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.288-295
    • /
    • 2009
  • We report the etch characteristics of GaAs and AlGaAs in the diffusion pump-based capacitively coupled $BCl_3$ plasma. Process variables were chamber pressure ($50{\sim}180$ mTorr), CCP power ($50{\sim}200\;W$) and $BCl_3$ gas flow rate ($2.5{\sim}10$ sccm). Surface profilometry was used for etch rate and surface roughness measurement after etching. Scanning electron microscopy was used to analyze the etched sidewall and surface morphology. Optical emission spectroscopy was used in order to characterize the emission peaks of the $BCl_3$ plasma during etching. We have achieved $0.25{\mu}m$/min of GaAs etch rate with only 5 sccm $BCl_3$ flow rate when the chamber pressure was in the range of 50{\sim}130 mTorr. The etch rates of AlGaAs were a little lower than those of GaAs at the conditions. However, the etch rates of GaAs and AlGaAs decreased significantly when the chamber pressure increased to 180 mTorr. GaAs and AlGaAs were not etched with 50 W CCP power. With $100{\sim}200\;W$ CCP power, etch rates of the materials increased over $0.3{\mu}m$/min. It was found that the etch rates of GaAs and AlGaAs were not always proportional to the increase of CCP power. We also found the interesting result that AlGaAs did not etched at 2.5 sccm $BCl_3$ flow rate at 75 mTorr and 100 W CCP power even though it was etched fast like GaAs with more $BCl_3$ gas flow rates. By contrast, GaAs was etched at ${{\sim}}0.3{\mu}m$/min at the 2.5 sccm $BCl_3$ flow rate condition. A broad molecular peak was noticed in the range of $500{\sim}700\;mm$ wavelength during the $BCl_3$ plasma etching. SEM photos showed that 10 sccm $BCl_3$ plama produced more undercutting on GaAs sidewall than 5 sccm $BCl_3$ plasma.

Direct numerical simulations of viscoelastic turbulent channel flows at high drag reduction

  • Housiadas Kostas D.;Beris Antony N.
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.3
    • /
    • pp.131-140
    • /
    • 2005
  • In this work we show the results of our most recent Direct Numerical Simulations (DNS) of turbulent viscoelastic channel flow using spectral spatial approximations and a stabilizing artificial diffusion in the viscoelastic constitutive model. The Finite-Elasticity Non-Linear Elastic Dumbbell model with the Peterlin approximation (FENE-P) is used to represent the effect of polymer molecules in solution, The corresponding rheological parameters are chosen so that to get closer to the conditions corresponding to maximum drag reduction: A high extensibility parameter (60) and a moderate solvent viscosity ratio (0.8) are used with two different friction Weissenberg numbers (50 and 100). We then first find that the corresponding achieved drag reduction, in the range of friction Reynolds numbers used in this work (180-590), is insensitive to the Reynolds number (in accordance to previous work). The obtained drag reduction is at the level of $49\%\;and\;63\%$, for the friction Weissenberg numbers 50 and 100, respectively. The largest value is substantially higher than any of our previous simulations, performed at more moderate levels of viscoelasticity (i.e. higher viscosity ratio and smaller extensibility parameter values). Therefore, the maximum extensional viscosity exhibited by the modeled system and the friction Weissenberg number can still be considered as the dominant factors determining the levels of drag reduction. These can reach high values, even for of dilute polymer solution (the system modeled by the FENE-P model), provided the flow viscoelasticity is high, corresponding to a high polymer molecular weight (which translates to a high extensibility parameter) and a high friction Weissenberg number. Based on that and the changes observed in the turbulent structure and in the most prevalent statistics, as presented in this work, we can still rationalize for an increasing extensional resistance-based drag reduction mechanism as the most prevalent mechanism for drag reduction, the same one evidenced in our previous work: As the polymer elasticity increases, so does the resistance offered to extensional deformation. That, in turn, changes the structure of the most energy-containing turbulent eddies (they become wider, more well correlated, and weaker in intensity) so that they become less efficient in transferring momentum, thus leading to drag reduction. Such a continuum, rheology-based, mechanism has first been proposed in the early 70s independently by Metzner and Lamley and is to be contrasted against any molecularly based explanations.

Retinoic Acid Increases the Cell Cycle Progression of Human Gingival Fibroblasts by Increasing Cyclin E and CDK 2 Expression and Decreasing $p21^{WAF1/CIP1}$ and $p16^{INK4A}$ Expression

  • You, Hyung-Keun;Seo, Se-Jeong;Kim, Kang-Ju;Choi, Na-Young;You, Yong-Ouk
    • International Journal of Oral Biology
    • /
    • v.37 no.3
    • /
    • pp.115-120
    • /
    • 2012
  • Retinoic acid plays an important role in the regulation of cell growth and differentiation. In our present study, we evaluated the effects of all-trans retinoic acid (RA) on cell proliferation and on the cell cycle regulation of human gingival fibroblasts (HGFs). Cell proliferation was assessed using the MTT assay. Cell cycle analysis was performed by flow cytometry, and cell cycle regulatory proteins were determined by western blot. Cell proliferation was increased in the presence of a 0.1 nM to 1 ${\mu}M$ RA dose range, and maximal growth stimulation was observed in cells exposed to 1 nM of RA. Exposure of HGFs to 1 nM of RA resulted in an augmented cell cycle progression. To elucidate the molecular mechanisms underlying cell cycle regulation by RA, we measured the intracellular levels of major cell cycle regulatory proteins. The levels of cyclin E and cyclin-dependent kinase (CDK) 2 were found to be increased in HGFs following 1 nM of RA treatment. However, the levels of cyclin D, CDK 4, and CDK 6 were unchanged under these conditions. Also after exposure to 1 nM of RA, the protein levels of $p21^{WAF1/CIP1}$ and $p16^{INK4A}$ were decreased in HGFs compared with the control group, but the levels of p53 and pRb were similar between treated and untreated cells. These results suggest that RA increases cell proliferation and cell cycle progression in HGFs via increased cellular levels of cyclin E and CDK 2, and decreased cellular levels of $p21^{WAF1/CIP1}$ and $p16^{INK4A}$.

Rheological Measurement of Fiber Spinnability of PVA Solution Dopes in DMSO

  • Chae, Dong-Wook
    • Textile Coloration and Finishing
    • /
    • v.22 no.3
    • /
    • pp.187-193
    • /
    • 2010
  • The effects of molecular weight (MW) and concentration on the rheological properties of poly(vinyl alcohol) (PVA) solutions in dimethyl sulfoxide (DMSO) were investigated at $30^{\circ}C$. Ubbelohde viscometer and rotational rheometer were employed for dilute and concentrated regime, respectively. In the dilute regime, the Mark-Houwink exponent ($\alpha$) of the solutions determined from three different MWs proved 0.73. The critical concentration (C*), in which the entanglement and overlap of polymer molecules began to take place, decreased with increasing the MW of PVA. Huggins constant ($K_H$) values ranged from 0.33 to 0.45 over the MW examined. In the log-log plot of $\eta_{sp}$ versus [$\eta$]C, the PVA with higher degree of polymerization (DP) gave a greater slope exhibiting the inflection point in the vicinity of C*. In the dynamic viscosity ($\eta'$) curve, the PVA solutions of DP 1700 presented Newtonian fluid behavior over most of the frequency range examined. However, the lower Newtonian flow region reduced with increasing the DP. As the PVA concentration increased, $\eta'$ was increased and the onset shear rate for pseudoplasticity was decreased. In the Cole-Cole plot, PVA solutions showed almost a single master curve in a slope of ca. 1.65 regardless of the DP. However, the increase of the concentration from 8 to 12 wt% for PVA solutions of DP 5000 decreased the slope from 1.73 to 1.57. In the tan $\delta$ curve, the onset frequency for sol-gel transition was shifted from 154 to 92 rad/s with increasing the DP from 3300 to 5000 and from 192 to 46 rad/s with increasing the concentration from 8 to 12 wt%. In addition, longer relaxation time ($\lambda$) was observed with increasing the DP and concentration.