A Study on the Molding Process of an Optical Communication Aspherical Glass Lens Using the Weight Molding Method (광통신용 비구면 글라스 렌즈 자중성형 공정 연구)

  • Ryu, Sang;Roh, Kyung Hwan;Choi, Kwang Hyeon;Kim, Won Guk;Lee, Won Kyung;Kim, Do Hee;Yang, Kuk Hyeon
    • Ceramist
    • /
    • v.21 no.4
    • /
    • pp.427-432
    • /
    • 2018
  • In this study, the aspherical lens for optical communications produced not with an one-step pneumatic type of external pressurization system (existed GMP process) but a constant weight of self-loaded mold put up to upper core. So the lens is molding with self-loaded weight molding and it calls Weight Molding process. In self-loaded molding process, we measured changes of center thickness molding lenses with each variable molding temperatures and time to find the effect of center of lens thickness to search key factors. As experimental results, the center thickness reach to targeted lenses step time value was changed drastically and it depends by molding temperature. If the molding temperature gets higher, the targeted lens that is reaching to the center thickness step time value was decreased. To find the effect of life improvement on mold core by imposing the self-loaded molding process we molded with GMP(Glass molding press) method and self-loaded molding method for 9,000 times and measured the lenses shape accuracy and surface roughness to evaluate the core life. As a result the self-loaded molding method core has 2,000 times longer that GMP (Glass molding press) method. If we adopt self-loaded molding method of the optical aspherical lens molding in the future, we expect that it would reduce the expense of changing the molds by molding core life improvements.

Preparation of PMMA Marbles by Film Molding Method (필름 성형법에 의한 PMMA 인조석의 제조)

  • 길기승;김의식;김대수
    • Polymer(Korea)
    • /
    • v.27 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • Two commercial processing methods have been used to produce poly(methyl methacrylate) (PMMA) marbles; cell molding method and belt molding method. Cell molding method has low productivity and belt molding method has high equipment cost as well as high production cost. A new production method far PMMA marbles using plastic films as molds was studied in this investigation to overcome the shortcomings of cell molding and belt molding method. As plastic film molds for producing PMMA marbles, poly(vinyl acetate) film was used. A methyl methacrylate compound, which has good processability in film molding and shows good mechanical properties after curing, was prepared and used to produce PMMA marbles by film molding method. Properties of the PMMA marbles produced by film molding method were similar to, or higher than, those of commercial PMMA marbles produced by cell molding and belt molding method respectively. The film molding method is considered to have high possibility in commercial application.

A Study on the Deformation Optimization of a Plastic Bezel Assembled on the Steering Wheel of an Automobiles (자동차 스티어링 휠에 조립되는 플라스틱 베젤의 변형 최적화에 관한 연구)

  • Han, Seong-Ryoel
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.105-112
    • /
    • 2017
  • In this study, plastics were deformed after molding due to the characteristics of the material. The Taguchi experimental design method was utilized to find the molding conditions that minimized deformation of the plastic bezel to be assembled in an automotive steering wheel. The injection molding conditions applied to the experimental design method are the melt temperature, cavity plate coolant temperature, core plate coolant temperature, and cooling time. Each condition was divided into five levels, and a total of 25 experiments were planned. However, instead of performing 25 actual molding experiments, the injection molding analysis was performed using the Moldflow program, and the deformation values for each molding analysis were obtained. The optimal molding conditions were obtained from these deformation values. The actual injection molding experiment using optimal molding conditions was compared with the deformation amount of the current molded product. The deformation was measured using a precise 3D scanner. The deformation amount of the molded product under optimal molding conditions was 16.1% lower than the deformation amount of the current molded product.

Development of the ultra-high speed electric injection molding machine using the energy regeneration method (에너지 회생 기법을 사용한 초고속 전동 사출성형기 개발)

  • Yu, Hyeon-Jae;Yoo, Sung-Chul;Hyun, Chang-Hoon;Park, Kyoung-Ho
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2016
  • High-speed and high-torque performance is required in the ultra-high speed electric injection molding machine field. To implement this performance, the big-size inverter is needed and the corresponding converter should be used. In this case, the whole cost for configuring the system will be increased. In this paper, we introduce a method which is able to reduce the energy and the cost for configuring the system using the energy regeneration. The energy regeneration method is based on reusing the regeneration power generated at the electric motor during decelerating the injection motion. In this paper, we demonstrate the effectiveness of the method by using the ultra-high speed injection motion.

A study on the optimum molding of plastic pulley using numerical analysis (수치해석을 이용한 플라스틱 풀리 성형품의 최적 성형에 관한 연구)

  • Kim, Kyung-A;Han, Seong-Ryeol
    • Design & Manufacturing
    • /
    • v.14 no.1
    • /
    • pp.30-35
    • /
    • 2020
  • Plastic pulleys used for the purpose of power transmission have to very high roundness characteristics. The roundness of plastic pulleys is influenced by many factors. In this study, the effect of molding conditions on the roundness of pulleys was analyzed using a numerical analysis program. To improve the roundness, molding conditions that minimize the amount of deformation of the pulley were studied through an experimental design method. Among the experimental design methods, the Taguchi method was used, and the main molding conditions affecting the deformation of the pulley were the resin temperature and the holding pressure. It was found that the amount of deformation is reduced by about 2.86% when molding with the optimum molding conditions compared to when the optimum molding conditions are not applied.

A method for Thermal Control of Nano Injection Molding using the Peltier Devices (펠티어 소자를 이용한 나노 사출 금형의 능동형 온도 제어)

  • Shin, H.;Kwon, J.;Hong, N.;Seo, Y.;Kim, B.
    • Transactions of Materials Processing
    • /
    • v.17 no.5
    • /
    • pp.337-342
    • /
    • 2008
  • The injection molding process has high accuracy and good reproducibility that are essential for mass production at low cost. Conventional molding processes typically use the water-based mold heating and air cooling methods. However, in the nano injection molding processes, this semi-active mold temperature control results in the several defects such as air-flow mark, non-fill, sticking and tearing, etc. In order to actively control temperature of the molds and effectively improve the quality of the molded products, the novel nano injection molding system, which uses active heating and cooling method, has been introduced. By using the Peltier devices, the temperature of locally adiabatic molds can be controlled dramatically and the quality of the molded patterns can be improved.

Development of a Convective Sequential Production System for Aspheric Lens (전도방식 순차제조 비구면 렌즈 제조시스템 개발)

  • Kuk, Kum-Hoan;Kim, Gab-Soon;Jung, Dong-Yean
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.202-210
    • /
    • 2011
  • The fabrication method of aspheric lens is changed from machining to press molding so as to improve the productivity. In the case of the press molding method, the temperature control of the molding die is most important, because the temperature of each molding die determines the quality of lens. But any practical method for direct measuring of the lens temperature and the die internal temperature is yet unknown. Besides, in the case of the press molding system in which the heating and pressing and cooing of a die is done at separate work stations, the lens productivity of the system for small lens is yet too low. The paper shows an improved structure of convective sequential system, the lens productivity of which is three times as many as the conventional convective system. To know the die internal temperature, numerical results are given using ANSYS. A new convective sequential system is developed and tested. Finally, the Taguchi method is applied in order to optimize the setting conditions of individual work station of the system.

Development of a Small Radiant Sequential Production System for Aspheric Lens (소형 복사방식 순차제조 비구면 렌즈 제조시스템 개발)

  • Kuk, Kum-Hoan;Jeong, Jun-Hyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.67-74
    • /
    • 2010
  • The fabrication method of aspheric lens is changed from machining to press molding so as to improve the productivity. In the case of the press molding method, the temperature control of the molding die is most impotent, because the temperature of each molding die determines the quality of lens. But any practical method for direct measuring of the lens temperature and the die internal temperature is yet unknown. Besides, in the case of the press molding system in which the heating and pressing and cooing of a die is done at one work station, the cycle time for the system is yet too long. The paper shows an improved structure of radiant sequential system in which the heating and pressing and cooing of dies is done at individual work station so as to cut down the cycle time. To know the die internal temperature, numerical results are given using ANSYS. An experimental radiant sequential system is developed and tested. Finally, the Taguchi method is applied in order to optimize the setting conditions of individual work station.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

A Study on Fuzzy Temperature Control for the Barrels of Injection Molding Machine using PC based PLC (PC 기반 PLC를 이용한 사출성형기 배럴의 퍼지 온도 제어에 관한 연구)

  • 김훈모
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.10
    • /
    • pp.768-773
    • /
    • 2003
  • Injection molding has been widely used for the mass production of a plastic product. With the development of the relative technique, various injection molding techniques have been developed and we could get more precise plastic product. The temperature of a melting resin is an important factor in the injection molding and this temperature has direct influence on the quality of a plastic product. In the present injection molding machine, the deriation of a temperature controlled by PID control method is within 2$^{\circ}C$ in the injection molding machine but PID control method takes too much time to stabilize after preheating and its overshoot is so big. We applied fuzzy control to alleriate the problem. In this research, we experimented the fuzzy temperature control with the usage of PC based PLC.