사출성형 조건 변화에 따른 도광판의 황화현산에 관한 연구 (A study on yellowing property of LGP under various injection molding conditions)

  • 이성준;민인기;김종선;이성희;윤경환
    • Design & Manufacturing
    • /
    • 제9권2호
    • /
    • pp.20-24
    • /
    • 2015
  • Recently, the light guide plate (LGP), a component of the BLU, becomes thinner and larger than ever. In industrial field, specialized injection molding technique is applied to mold the ultra-thin LGP such as a ultra-high speed injection molding. Usually very high melt temperature is used for low viscosity. High injection speed and melt temperature lead to yellowing of LGP. In the present paper a series of injection molding experiment was performed under various injection molding conditions. Yellow index, CIE xy, spectral transmittance of sample were measured using the UV-Visible spectrophotometer. Systematic decrease of spectral transmittance in UV-B range was found as the melt temperature was higher. Yellow index and CIE xy were became higher near the gate location in LGP. From the result of analysis of variance, the main factor to affect for yellow index was mold temperature and that for spectral transmittance(at 315 nm) was melt temperature.

  • PDF

우레탄레진(TSR-755)을 적용한 시작형 사출금형 연구 (Injection mold development applying starting mold material, urethane resin(TSR-755))

  • 김광희;김정식
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4392-4397
    • /
    • 2012
  • 본 연구에서는 우레탄레진(TSR-755)을 이용하여 레이저 조형으로 시작형 몰드를 가공하고, 상용패키지(Unigraphics)를 이용하여 자동차 단자함 케이블 케이스를 설계한 후 사출성형해석(Simpoe-Mold)을 사용하여 충전, 보압, 냉각, 변형해석을 수행하여 게이트 위치 선정 및 냉각 사이클 등을 검토 하였다. 해석결과, 세라믹소재 가공 후 사출금형에 인서트시켜 성형 시 열전도도 및 냉각시간을 줄여 줌을 확인할 수 있으며, 게이트 및 냉각라인 선정을 빠른 시간에 결정할 수 있어 생산성 향상을 가져올 것으로 나타났다.

금형 기반 진동 신호 패턴의 유사도 분석을 통한 사출성형공정 변화 감지에 대한 연구 (A Study on Detecting Changes in Injection Molding Process through Similarity Analysis of Mold Vibration Signal Patterns)

  • 김종선
    • Design & Manufacturing
    • /
    • 제17권3호
    • /
    • pp.34-40
    • /
    • 2023
  • In this study, real-time collection of mold vibration signals during injection molding processes was achieved through IoT devices installed on the mold surface. To analyze changes in the collected vibration signals, injection molding was performed under six different process conditions. Analysis of the mold vibration signals according to process conditions revealed distinct trends and patterns. Based on this result, cosine similarity was applied to compare pattern changes in the mold vibration signals. The similarity in time and acceleration vector space between the collected data was analyzed. The results showed that under identical conditions for all six process settings, the cosine similarity remained around 0.92±0.07. However, when different process conditions were applied, the cosine similarity decreased to the range of 0.47±0.07. Based on these results, a cosine similarity threshold of 0.60~0.70 was established. When applied to the analysis of mold vibration signals, it was possible to determine whether the molding process was stable or whether variations had occurred due to changes in process conditions. This establishes the potential use of cosine similarity based on mold vibration signals in future applications for real-time monitoring of molding process changes and anomaly detection.

배전용 폴리머 라인 포스트 애자 금형의 불량과 대책에 관한 연구 (A study on the defects of molds for distribution polymer line post insulators and problem-solving measures)

  • 김세환;최계광
    • Design & Manufacturing
    • /
    • 제6권2호
    • /
    • pp.12-16
    • /
    • 2012
  • In this study, an injection mold is made to produce polymer line post insulators. FRP (fiber reinforced plastics) is covered by silicone housing. In injection molding process, chances for offcenter are 60 percent. Given the structure of the product, offcenter occurs owing to the imbalances in positions of gates and improper -designs of cores and jigs. This study focuses on mold modifications and improvements.

  • PDF

의사 솔리드 모델의 캐비티 및 코어판 생성 (Generation of Cavity and Core Plates of an Injection Mold for a Pseudo-Solid Part Model)

  • 장진우;이상헌;임성락
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1601-1604
    • /
    • 2003
  • This paper describes a split operation for generation of core and cavity plates of an injection mold for a pseudo-solid model of a plastic part. Here, a pseudo-solid model means a sheet model that looks like a solid model. but whose boundary is not closed. When a solid model created in a different CAD system is imported through standard data exchange format, a pseudo-solid model is created in most cases as tolerance or some other problems make sewing operation failed. As most existing mold design system based on solid modeling kernels require a complete part solid model, mold designers have to do time-consuming healing operations to convert a pseudo-solid to solid. The essential capability of mold design system is the split operation for generation of core and cavity plates. Thus. we developed a split operation for pseudo-solid part model to eliminate or reduce healing preprocessing for mold design.

  • PDF

자동차 주유구 커버에 대한 사출성형과 2색 코팅 동시 구현에 관한 연구 (A study on simultaneous injection molding and two-color coating for car gas cap cover)

  • 배형섭;박동현;김부곤;서창호;허원근;이호상
    • Design & Manufacturing
    • /
    • 제15권1호
    • /
    • pp.32-40
    • /
    • 2021
  • Mold design for in-mold coating was carried out to achieve simultaneous injection molding and two-color coating for car gas cap cover. The developed mold includes one core and three cavities which are composed of a substrate cavity and two coating cavities. To provide a sealing edge for complete seal during the second coating, the first coated material was used at the boundary between the first coating and the second one, and injection molded substrate was used at the parting line. The materials used were PC/ABS for substrate and 2-component Polyurea for coating. Through experiments, it was found that the suggested sealing edges were effective for complete seal during the second coating. In cavity pressure traces, there were three peaks caused by mold closing, coating-material injection and cleaning-piston advancement inside the mixing head. The cavity pressure increased with decreasing coating thickness.

사출성형 CAE 프로그램을 이용한 코어 휨의 예측 (Prediction of Core Shift using Injection Molding CAE program)

  • 문정연;곽민혁;박태원;정영득
    • Design & Manufacturing
    • /
    • 제8권2호
    • /
    • pp.7-11
    • /
    • 2014
  • The Core-Shift is often generated on injection mold which have thin and long core. And Core-Shift brings out problems for thickness variation and product ejecting process. In this study, analysis of Core-Shift was performed according to change of materials of core(steel P-20, Be-Cu) and various polymers(PP, PC) by using MoldFolw MPI 6.1 which is commercial injection molding analysis program. As the results of analysis, the magnitude of Core-Shift was increased as being use polymer had lower fluidity and lower rigidity core. In the future, we will study the relationship between amount of Core-Shift and ejecting force.

  • PDF

Multi-cavity 프리폼 사출 금형 코어의 표면 품질 및 균일도 향상을 위한 연마 자동화 기구 개발 (A development of automated polishing apparatus for surface quality and uniformity of multi-cavity preform injection mold core)

  • 이정원;서금희;윤길상
    • Design & Manufacturing
    • /
    • 제8권2호
    • /
    • pp.41-45
    • /
    • 2014
  • Automated polishing apparatus based on the research have been developed. The research is improvement of polishing process for surface quality and uniformity improvement of preform injection mold core. Surface quality of preform core have influence on ejecting and product quality after injection molding. Thus, the current being made by hand to automate the polishing process, the surface of the preform to improve the quality and uniformity improvement. First made a division by analyzing manual process a step-by-step. And draw a mechanism for converting mechanical movement. Automated polishing apparatus for preform core was developed, through which shortens production time and were able to secure the safety of the worker.

  • PDF

플라스틱 마이크로 채널 기판 사출성형 시 보압의 영향 (Effects of Packing Pressure and Time on Injection Molding of Plastic Micro-channel Plates)

  • 우상원;박시환
    • 한국생산제조학회지
    • /
    • 제25권3호
    • /
    • pp.224-229
    • /
    • 2016
  • Recently, polymeric micro-fluidic biochips with numerous micro patterns on the surface were fabricated by injection molding for realizing low-cost mass production of devices. To evaluate the effects of process parameters on large-scale micro-structure replication, a $50{\times}50mm^2$ tool insert with surface structures having a patterns of trapezoidal shapes (height: $30{\mu}m$) was employed. During injection molding, PMMA was used; packing phase parameters and mold temperature were investigated. The replicated surface textures were quantitatively characterized by confocal laser microscopy with 10-nm resolution. The degree of replication at low mold temperatures was found to be higher than that at high mold temperature at the beginning of the packing stage. Thereafter, the degree of replication increased to a greater extent at higher mold temperatures; application of higher mold temperatures improved the degree of replication.